Tia 2 - Temperature converter DIN rail mounting - Universal input - 1

Tia2 Convertisseur de temperature montage rail DIN - Entree universelle Temperature converter DIN rail mounting - Universal input J Fonction j Function Les convertisseurs de temperature Tia2 sont des modules programmables pour de nombreux signaux d'entree : • Conversion de signaux de sonde a resistance (Pt100/1000,Ni100/1000) ou de thermocouple. • Conversion de resistance lineaire (mesure de niveau, positionnement de vanne). • Conversion de signaux de tension (mV) et Ohmiques. Montage rail DIN. Installables en zone explosible (CF codification). Tia2 temperature converters are aimed at converting signals coming from large panel of input signals: • Conversion of temperature measurement with RTD100, RTD1000, Ni100, Ni1000 or thermocouple. • Conversion of linear resistance variation (from level sensors or valves). • Voltage (mV) and ohmic measurement. DIN rail mounting Certified to be installed in explosive atmosphere (see codification). Caracteristiques electriques Electrical data Entree capteur Sortie Alimentation Modele standard Version ATEX Programmable (voir tableau au verso) 4/20 mA Input Output Power supply Standard model ATEX version Programmable (refer to backside) 4/20 mA 10V . 30 Vdc 10V . 28 Vdc Isolement galvanique 1500V AC Precision < 0,1% de l'E.M. ou < precision de base (CF verso) selon la plus grande des deux valeurs Resistance de charge (Valimentation-10) / 0,0215 0 Detection de rupture de sonde ou de court circuit : Accuracy < 0.1% F.S. or < basis accuracy (refer to backside) according to the most important value Load resistance (Vsupply-10) / 0.0215 0 Shorted or broken line detection: Configurable Temps de chauffe Temps de reponse Derive Tension d'alimentation 3,5 mA ou 21,5 mA (NAMUR NE43) 5 minutes < 2 secondes <0,01% du courant de boucle pour variation de 0,1% de tension d'alimentation < 10% de la precision / degre 1.5x la precision de base pour une SF a 0°C Temperature : Erreur due a la CSF Erreur due a la resistance de ligne : Pt100 2 fils* / 3 fils** 2.5°C/ 0 Pt1000 2 fils* / 3 fils** 0.25°C/ 0 Ni100 2 fils* / 3 fils** 2°C/ 0 Ni1000 2 fils* / 3 fils** 0.2°C/ 0 * Compensable par configuration / ** : desequilibre entre fils Immunite CEM < 0,1% de l'E.M. Configurable Warm-up time Response time Drift Voltage supply Temperature Error due to CJC Line resistance effect RTD100 2wires* / 3wires' RTD1000 2wires* / 3wires** 0.25°C/ 0 3.5 mA to 21.5 mA (NAMUR NE43) 5 minutes < 2 s < 0.01% of the current in the loop for a variation of 0.1% of Vsupply < 10% of accuracy / degree 1.5x basis accuracy for a cold junction at 0°C 2°C/ 0 0.2°C/ 0 * Compensation is configurable / ** : unbalance between wires EMC Immunity < 0.1% F.S. J Caracteristiques mecaniques J Mechanical data Presentation Protection Masse T° d'utilisation T° de stockage Humidite relative Raccordement Taille maxi des fils Boitier polycarbonate l = 13 mm, h = 110 mm, p = 110 mm IP 20 approx. 200 g. -40°C a +60°C (modeles NON ATEX) -40°C a +60°C 5% a 95% sans condensation. Bornes a visser demontables de 1x0,2 mm2 a 1x2,5 mm2 Housing Protection Weight Working T° Storage T° Relative humidity Connection Max. wire size Polycarbonate l = 13 mm, h = 110 mm, p = 110 mm IP 20 approx. 200 g -40°C to 60°C (non ATEX version) -40°C to 60°C 5% to 95% without condensing Removable screw terminals from 1x0,2 mm2 to 1x2,5 mm2 Concernant les produits ATEX et lECEx : Securite Intrinseque EN 60079-0 & CEI 60079-0 EN 60079-11 & CEI 60079-11 EN60079-26 & CEI 60079-26 Securite par protection «n» EN 60079-15 & CEI 60079-15 N° d'attestation Ex ia INERIS 13ATEX0015X & INE13.0022X Ex nA INERIS 13ATEX3006X & INE13.0023X For ATEX and IECEx products: Intrinsic Safety «n» type of protection Certificate N° Ex ia Ex nA Classement IECEx / IECEx Classification Parametres d'entree (Versions «ia» et «iaD») Input parameters ("ia " and "iaD" versions) Entre les bornes / Between terminals «-» & «+» U I Pi C L Parametres d'entree (Versions « nA » ) / Input parameters ("nA" versions) Entre les bornes / Between terminals «-» & «+» U max I max P max 28V 100 mA 700 mW Parametres de sortie / Output parameters Entres les bornes / Between terminals «1»,»2», «3» & «4» " Uo I_~ Po Co Lo” ^BParametres ATEX de securite / ATEX safety parameters FC-Tia2-FREN-23-09-2015 Subject to modifications due to technical advances / Soucieux d'ameliorer nos produits, nous nous reservons le droit de reviser sans preavis les caracteristiques de nos produits

Open the catalog to page 1
Tia 2 - Temperature converter DIN rail mounting - Universal input - 2

Type de protection Method of protection ■ Caracteristiques d'entree du capteur / Input specifications Entree capteur Pt100 2,3,4 fils (EN60751) Pt1000 2,3,4 fils (EN60751) Ni100 2,3,4 fils NI1000 2,3,4 fils Tension 60 mV Resistance 3600 2,3,4 fils Resistance 40000 2,3,4 fils Input signal Precision de base en fonction de la T° mesuree Basis accuracy according to measured T° Totalite de l'etendue de mesure Full range Le parametrage peut s'effectuer de 2 fagons : - A l'aide du logiciel ProgressXmanager. - Par FDT/DTM Ces supports de programmation (ProgressXmanager, CommDTM GEORGIN et DTM Tia2)...

Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages