S5DI - Intrinsic safety probe with neck and insert ATEX Ex ia - 1

S5DI Sonde a extension avec element de mesure interchangeable ATEX Ex ia Intrinsic safety probe with neck and insert ATEX Ex ia ■ Fonction Sonde de temperature ATEX Ex ia a visser avec extension et tete de raccordement et element de mesure interchangeable suivant codification (voir au verso) ■ Function ATEX Ex ia threaded temperature probe with neck and connection head and interchangeable sensing element according to codification (see backside) Caracteristiques Temperature d'utilsation Sonde Pt100 : Classe A suivant IEC751 -200°C a +600°C suivant montage : Cable Teflon (PTFE) -50°C a +250°C Cable fibre de verre -50°C a +400°C Conducteur Nickel a isolant mineral -200°C a +600°C Thermocouple type Simple ou double T (Cu/CuNi), J (Fe/CuNi), K (NiCr/NiAl) Plage de mesure : en fonction du type de thermocouple Tolerances Classe 1 DIN suivant IEC 584.2 Autre sur demande Montage Raccordement Pt100 simple 1x3 fils ou Double 2x3 fils Thermocouple simple ou double Element de mesure interchangeable Gaine de protection Acier inox 316 L 1.4404 Extension longueur 100 mm (standard) Diametre standard 6 mm ou 8 mm Longueur utile (mm) 50, 100, 150, 200, 250, 300, 350 Autre sur demande Raccordement procede Raccord 1/2"GC ou NPT male avec extension Tete de raccordement Type NA Exia II 1G/D IICT6 securite intrinseque en alliage d'aluminium revetue epoxy Entree electrique par presse etoupe M20x1.5 polyamide ATEX Exia Raccordement electrique Bornier ceramique 3 ou 6 plots Ou via transmetteur en option Test d'isolement >100MOhm voltage 250V / T°Amb. (Pt100) 1000 MW/ test voltage 500 V DC (Thermocouple) Temps de reponse t0,5 = 3,5 s / t0,9 = 8 s Effectue dans l'eau a 0,4 m/s selon DIN EN 60751 Pression maxi admissible 40 bar (4 MPa) a 20°C Options Transmetteur sortie 4-20 mA Voir fc-TiXo*-fren ■ Parametres de securite Caracteristiques max. d'entree au bornier de raccordement (capteurs sans transmetteur) Umax = 30V Imax = 125mA Certifications Versions ATEX INERIS 02ATEX0049X/01 Securite intrinseque EN 60079-0 et EN 60079-11 Ex ia IIC T4... T6 ** Ga T° amb. : -40 a *°C * suivant transmetteur en tete i Technical data Temperature range RTD Pt100: Grade A according to IEC751 (Standard) -200°C a +600°C according to the type of manufacturing: Teflon cable (PTFE) -50°C to +250°C Fiber glass cable -50°C to +400°C Mineral insulated nickel conductors -200°C to +600°C Thermocouple type Single or double: T (Cu/CuNi), J (Fe/CuNi), K (NiCr/NiAl) Range: according to the type of thermocouple Tolerances according to class 1 DIN IEC 584.2 Other available on request Manufacturing Single RTD100 1x3 wires or Dual 2x3 wires Single or double thermocouple Interchangeable measuring element Material sheath SS316 L 1.4404 Neck 100 mm (standard) Diameter 6 mm or 8 mm (standard) Useful length (mm) 50, 100, 150, 200, 250, 300, 350 Other available on request Process connection Thread 1/2"BSP or NPT male with extension Terminal head Type NA Exia II 1G/D IICT6 intrinsic safety aluminium cast epoxy coated Electric connection cable gland M20x1.5 material polyamide ATEX Exia Terminal Block Ceramic terminal block 3 or 6 poles Or via transmitter (Option) Isolation resistance >100MOhm voltage 250V / Amb.T° (RTD100) 1000 MW/ test voltage 500 V DC (Thermocouple) Response time t0.5 = 3.5 s / t0.9 = 8 s In water 0.4 m/s according DIN EN 60751 Maximum pressure 40 bar (4 MPa) to 20°C Options 4-20 mA output Transmitter ■ Safety parameters Max. input characteristics at the terminal block (without transmitter) Umax = 30V Imax = 125mA i Certifications ATEX versions INERIS 02ATEX0049X/01 Ex ia IIC T4... T6 ** Ga T° amb. : -40 a *°C * suivant transmetteur en tete FC-S5DI-FREN-15-10-2013 Subject to modifications due to technical advances / Soucieux d'ameliorer nos produits, nous nous reservons le droit de reviser sans preavis les caracteristiques de nos produits

Open the catalog to page 1
S5DI - Intrinsic safety probe with neck and insert ATEX Ex ia - 2

S5DI Sonde a extension avec element de mesure interchangeable ATEX Ex ia Intrinsic safety probe with neck and insert ATEX Ex ia KNE Type de tete Terminal head Element sensible Sensing element Montage Assembly Classe de precision Grade Nature de la gaine Protection Sheath Raccord process R1 Process connection R1 ZZ^Autre preciser / Other on request Longueur de gaine L1 Insertion length L1 Autre / Other Z Autre preciser / Other on request Autre preciser / Other on request Longueur extension Neck length Entree electrique Input Terminaison electrique Connection

Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages