This document provides technical specifications and codification details for the S1VF screw-in temperature probe with a terminal head, manufactured by GEORGIN. The probe is designed for temperature measurement in various industrial applications.

Specifications
  • Temperature Range: The probe supports a range of -200°C to +600°C, depending on the manufacturing type. Specific ranges are provided for different cable types: Teflon (PTFE) cable (-50°C to +250°C), fiber glass cable (-50°C to +400°C), and mineral insulated nickel conductors (-200°C to +600°C).
  • Thermocouple Types: Available in single or double configurations, including types T (Cu/CuNi), J (Fe/CuNi), and K (NiCr/NiAl), with tolerances according to class 1 DIN IEC 584.2.
  • Material and Dimensions: The sheath is made of SS316 L 1.4404 stainless steel, with standard diameters of 6 mm or 8 mm and useful lengths ranging from 50 mm to 300 mm.
  • Process Connection: Standard thread options include 1/2” BSP or NPT male under the head.
  • Terminal Head: Type NA aluminium cast epoxy coated, with an electric connection via a cable gland M20x1.5 IP68, suitable for temperatures from -40 to +200°C without a transmitter.
  • Isolation Resistance: Greater than 100MOhm at 250V for RTD100 and 1000 MW at 500 V DC for thermocouples.
  • Response Time: t0.5 = 3.5 s and t0.9 = 8 s in water at 0.4 m/s according to DIN EN 60751.
  • Maximum Pressure: 40 bar (4 MPa) at 20°C.

Options
Includes a 4-20 mA output transmitter and various terminal head types and configurations.

Codification
The document provides a detailed codification system for specifying the probe's features, including terminal head type, sensing element, assembly, precision class, temperature rating, protection sheath, process connection, sheath diameter, insertion length, neck length, electrical input, and termination. Examples of codification are provided to guide users in selecting the appropriate configuration for their needs.
See more

Catalog excerpts

S1VF - Probe screw-in with terminal head-1

S1VF Sonde à visser avec tête de raccordement Probe screw-in with terminal head Sonde de température à visser avec tête de raccordement suivant codification (voir au verso) Threaded temperature probe with connection head according to codification (see backside) Technical data Température d’utilsation Temperature range Sonde Pt100 : Classe A suivant IEC751 -200°C à +600°C suivant montage : RTD Pt100: Grade A according to IEC751 (Standard) -200°C à +600°C according to the type of manufacturing: Câble Téflon (PTFE) Teflon cable (PTFE) Câble fibre de verre Fiber glass cable Conducteur Nickel à isolant minéral -200°C à +600°C Mineral insulated nickel conductors -200°C to +600°C Thermocouple type Single or double: T (Cu/CuNi), J (Fe/CuNi), K (NiCr/NiAl) Range: according to the type of thermocouple Tolerances according to class 1 DIN IEC 584.2 Other available on request Raccordement Pt100 simple 1x3 fils ou Double 2x3 fils (Standard) Thermocouple simple ou double Single RTD100 1x3 wires or Dual 2x3 wires (Standard) Single or double thermocouple Acier inox 316 L 1.4404 Diamètre standard 6 ou 8 mm Material sheath Raccordement procédé Raccord 1/2”GC ou NPT mâle sous tête (Standard) Process connection Thread 1/2”BSP or NPT male under head (Standard) Tête de raccordement Type NA en alliage d’aluminium revêtue époxy (Standard) Entrée électrique par presse étoupe M20x1,5 IP68 -40 à + 200°C (sans transmetteur) Terminal head Type NA aluminium cast epoxy coated (Standard) Electric connection cable gland M20x1.5 IP68 -40 to + 200°C (without transmitter) Raccordement électrique Bornier céramique 3 ou 6 plots (Standard) Ou via transmetteur en option Terminal Block Ceramic terminal block 3 or 6 poles (Standard) Or via transmitter (Option) Test d’isolement >100MOhm voltage 250V / T°Amb. (Pt100) 1000 MW/ test voltage 500 V DC (Thermocouple) Isolation resistance >100MOhm voltage 250V / Amb.T° (RTD100) 1000 MW/ test voltage 500 V DC (Thermocouple) Response time Effectué dans l’eau à 0,4 m/s selon DIN EN 60751 Pression maxi admissible 40 bar (4 MPa) à 20°C Maximum pressure 4-20 mA output Transmitter Refer to fc-TiXo*-fren Transmetteur sortie 4-20 mA Voir fc-TiXo*-fren FC-S1VF-FREN-15-10-2013 Subject to modifications due to technical advances / Soucieux d’améliorer nos produits, nous nous réservons le droit de réviser sans préavis les caractéristiques de nos produits Thermocouple type Simple ou double T (Cu/CuNi), J (Fe/CuNi), K (NiCr/NiAl) Plage de mesure : en fonction du type de

 Open the catalog to page 1
S1VF - Probe screw-in with terminal head-2

Element sensible Sensing element Montage Assembly Classe de precision Grade Nature de la gaine Protection Sheath Raccord process R1 Process connection R1 Longueur de gaine L1 Insertion length L1 Longueur extension Neck length ZZ Autre preciser / Other on request Sans / Without Entree electrique Input Terminaison electrique Connection

 Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2  Pages

  2. GP Serie

    2  Pages

  3. GS/GSX

    2  Pages

  4. SR2 series

    2  Pages

  5. TR/TA.02

    2  Pages

  6. TR/TA.01

    2  Pages

  7. GR/GA

    2  Pages

  8. (D)MLFK

    2  Pages

  9. AIRGAS

    2  Pages

  10. U series

    2  Pages

  11. P Series

    16  Pages

  12. SG

    2  Pages

  13. BVL/M/NT(I)

    2  Pages

  14. BEKA's range

    182  Pages

  15. GN 25000

    2  Pages

  16. GN 21000

    2  Pages

  17. GH 11000

    2  Pages

  18. GC 52500

    2  Pages

  19. GC 52100

    2  Pages

  20. GB 64000

    2  Pages

  21. fc-pn

    48  Pages

  22. fc-gc6rfbg

    2  Pages

  23. fc-fm

    39  Pages

  24. A3300-31/51

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.