The Isolation Amplifier GN 25000 is used for isolation and conversion of 0/4 ... 20 mA and 0/2 ... 10 V standard signals. The input and output range of GN 25000 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply. • Calibrated signal setting Input and output range can be set by using DIP switch - high precision without any further adjustment • 3-Port Isolation Protection against erroneous measurements due to parasitic voltages or ground loops • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage • Maximum reliability No maintenance costs • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Open the catalog to page 1Technical Data Input Input signal 0 ... 20 mA 4 ... 20 mA Input resistance Current input < 25 Q Voltage input < 30 V Load Current output: < 12 V (600 Q at 20 mA) Voltage output: < 5 mA (2 kQ at 10 V) Linear transmission range-1 ... +110 % Ripple < 10 mVrms General Data Transmission error< 0.1 % full scale Temperature coefficient 1< 100 ppm/K Cut-off frequency -3 dB (switchable)5 kHz100 Hz 10 Hz Response time T99150 ps 7 ms70 ms Test voltage3 kV AC, 50 Hz, 1 min.Input against output against power supply Working voltage2) (Basic insulation) Up to 600 V AC/DC for...
Open the catalog to page 2All GEORGIN S.A. catalogs and technical brochures
-
S5UI
2 Pages
-
GP Serie
2 Pages
-
GR/GA - Pressure transmitter
2 Pages
-
BZG - Zener Barrier
2 Pages
-
FKG - Pressure transmitter
8 Pages
-
FKE - Level transmitter
8 Pages
-
GS/GSX
2 Pages
-
SR2 series
2 Pages
-
TR/TA.02
2 Pages
-
TR/TA.01
2 Pages
-
GR/GA
2 Pages
-
(D)MLFK
2 Pages
-
AIRGAS
2 Pages
-
U series
2 Pages
-
Pressostat - Thermostat série F
16 Pages
-
P Series
16 Pages
-
SG
2 Pages
-
BVL/M/NT(I)
2 Pages
-
BEKA's range
182 Pages
-
GN 21000
2 Pages
-
GH 11000
2 Pages
-
GC 52500
2 Pages
-
GC 52100
2 Pages
-
GB 64000
2 Pages
-
fc-pn
48 Pages
-
fc-gc6rfbg
2 Pages
-
fc-fm
39 Pages
-
process transmitter FKC series
10 Pages
-
A3300-31/51
2 Pages