GN 21000
2Pages

{{requestButtons}}

Catalog excerpts

GN 21000 - 1

GN 21000 Signal Splitter/Repeater Isolation, Conversion and Loop Supply of Standard Signals with 2 Outputs Surete des Procedes Industriels The Signal Splitter/Repeater GN 21000 is used for isolation, conversion and distribution of 0/4 ... 20 mA, 0/1 ... 5 V and 0/2 ... 10 V standard signals. The measuring input can also supply the loop power for 2-wire transmitters. The input and two isolated outputs can be easily configured by using DIP switch. Due to the calibrated range selection no further adjustment is necessary. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply. • Universal configurable operating Signal isolator or repeater power supply for 2-wire transmitters, 2 independent outputs • Calibrated signal setting Input and outputs can be set by using DIP switch - high precision without any further adjustment • 4-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage • Maximum reliability No maintenance costs • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

Open the catalog to page 1
GN 21000 - 2

Input resistance Current input < 35 Q Transmitter supply Tx (switchable) 16 V (open circuit voltage /short circuit current < 22 V/35 mA) Output I / Output II Output signal 0 ... 20 mA 0 ... 10 V 0 ... 5 V LoadCurrent output: < 6 V (300 Q at 20 mA)Voltage output: < 5 mA (2 kQ at 10 V) Linear transmission range-1 ... +110 % Ripple < 10 mVrms General Data Transmission error< 0.1 % full scale Temperature coefficient')< 100 ppm/K Cut-off frequency -3 dB5 kHz Response time T99150 ps Test voltage3 kV AC, 50 Hz, 1 min.Input against Output I against Output II against power...

Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GH 11000

    2 Pages

  17. GC 52500

    2 Pages

  18. GC 52100

    2 Pages

  19. GB 64000

    2 Pages

  20. fc-pn

    48 Pages

  21. fc-gc6rfbg

    2 Pages

  22. fc-fm

    39 Pages

  23. A3300-31/51

    2 Pages