GC 52500 - 1

The Repeater Power Supply GC 52500 is used to supply and separate 2- and 3-wire SMART Transmitters and active sensor signals with HART communication. It supplies the transmitter with power and transmits the measuring signal with high accuracy galvanic isolated to the output. Alternative the measuring input accepts active 0/4 ... 20 mA signals from 4-wire transmitters. In addition to the analog signal, the GC 52500 also transmits data protocols for HART communication with the field device from every point of the cabling. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply. • Universal operation of SMART Transmitters Energization and separation of field located 2-, 3- and 4-wire transmitters • Bidirectional HART transmission HART data transfer for repeater and isolator operation • 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops • Extremely slim design 6.2 mm slim housing for a simple and space saving installation • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation • Protective Separation acc. to EN61140 Protects service personnel and downstream devices against impermissibly high voltage • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender

Open the catalog to page 1
GC 52500 - 2

Technical Data Input Input signal_0/4 ... 20 mA_(4 ... 20 mA with HART signal)_ Transmitter supply (Tx)_16 V (open circuit voltage / short circuit current < 22 V / 35 mA) Communication signal Bidirectional HART transmission, internal AC impedance ~ 250 Q Output Output signal_ Linear transmission range_ Ripple General Data Transmission error_ Test voltage_ Working voltage2) (Basic Insulation) 0/4 ... 20 mA_(4 ... 20 mA with HART signal) 0 ... 600 Q (at 20 mA) (230 ... 600 Q with HART signal) -1 ... +110 %_ Protection against electrical shock2) Ambient temperature 3 kV AC, 50 Hz, 1 min....

Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52100

    2 Pages

  19. GB 64000

    2 Pages

  20. fc-pn

    48 Pages

  21. fc-gc6rfbg

    2 Pages

  22. fc-fm

    39 Pages

  23. A3300-31/51

    2 Pages