Powering and Isolation of 2- and 3-wire Transmitters The repeater power supply GC 52100 is used to supply and separate 2- and 3-wire transmitters and active sensor signals. The repeater power supply supplies the transmitter with power and transmits the current or voltage measuring signal with high accuracy galvanic isolated to the output. Alternative the measuring input accepts active signals from 4-wire transmitters. The input and output range of GC 52100 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply. • Universal operation of Transmitters Energization and separation of field located 2-, 3- and 4-wire transmitters with current or voltage output • Calibrated signal setting Input and output range can be set by using DIP switch - high precision without any further adjustment • 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Open the catalog to page 1(calibrated switchable) Input resistancecurrent input < 25 Qvoltage input >100 kQ Overload50 mA / 30 V Transmitter supply (Tx) 17 V at 20 mA (open circuit / short circuit < 22 V / 35 mA) (calibrated switchable) LoadCurrent output: < 12 V (600 Q at 20 mA)Voltage output: < 5 mA (2 kQ at 10 V) Linear transmission range-1 ... +110 % Residual ripple < 10 mVrms General Data Transmission error< 0.1 % full scale Temperature coefficient')< 100 ppm/K Cut-off frequency -3 dB (switchable)5 kHz100 Hz Response time T99150 ps7 ms Test voltage3 kV AC, 50 Hz, 1 min. Input against output against power...
Open the catalog to page 2All GEORGIN S.A. catalogs and technical brochures
-
S5UI
2 Pages
-
GP Serie
2 Pages
-
GR/GA - Pressure transmitter
2 Pages
-
BZG - Zener Barrier
2 Pages
-
FKG - Pressure transmitter
8 Pages
-
FKE - Level transmitter
8 Pages
-
GS/GSX
2 Pages
-
SR2 series
2 Pages
-
TR/TA.02
2 Pages
-
TR/TA.01
2 Pages
-
GR/GA
2 Pages
-
(D)MLFK
2 Pages
-
AIRGAS
2 Pages
-
U series
2 Pages
-
Pressostat - Thermostat série F
16 Pages
-
P Series
16 Pages
-
SG
2 Pages
-
BVL/M/NT(I)
2 Pages
-
BEKA's range
182 Pages
-
GN 25000
2 Pages
-
GN 21000
2 Pages
-
GH 11000
2 Pages
-
GC 52500
2 Pages
-
GB 64000
2 Pages
-
fc-pn
48 Pages
-
fc-gc6rfbg
2 Pages
-
fc-fm
39 Pages
-
process transmitter FKC series
10 Pages
-
A3300-31/51
2 Pages