Catalog excerpts
GB 64000 Bipolar Isolation Amplifier Isolation and Conversion of Bipolar and Unipolar Industrial Standard Signals The Bipolar Isolation Amplifier GB 64000 is used for isolation and conversion of bipolar and unipolar industrial standard signals. The input and output range of GB 64000 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary. • Calibrated signal setting Input and output range can be set by using DIP switch - high precision without any further adjustment • High bandwidth; short response time No signal distortion; no falsification of measured signal A switchable compensation of the measuring range can be performed at the Zero/Span potentiometers on the front panel. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply. • Switchable Zero/Span compensation For readjustment of the sensor or field device • 3-Port isolation Protection against erroneous measurements due to parasitic voltages or ground loops • Extremely slim design 6.2 mm slim housing for a simple and space saving DIN rail mounting • Optional In-Rail-Bus mounting rail connector allows for fast and economical installation • Protective Separation acc. to EN 61140 Protects service personnel and downstream devices against impermissibly high voltage • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Open the catalog to page 1Input Input signal (calibrated switchable) Input resistance_ (calibrated switchable)± 10 mA 0 ... 10 mA 2 ... 10 mA± 5 V 0 ... 5 V 1 ... 5 V Load< 12 V (600 Q at 20 mA)< 5 mA (2 kQ at 10 V) Linear transmission rangeunipolar: -1 ... +110 % bipolar: -110 ... +110 % Residual ripple < 10 mVrms General Data Transmission error< 0.1 % full scale Temperature coefficient')< 100 ppm/K Zero/Span compensation (switchable)± 5 % of measuring range Cut-off frequency (-3 dB)8 kHz100 Hzswitchable Response time (T10-90)100 ps7 ms Test voltage3 kV AC, 50 Hz, 1 min. Input against output against power...
Open the catalog to page 2All GEORGIN S.A. catalogs and technical brochures
-
S5UI
2 Pages
-
GP Serie
2 Pages
-
GR/GA - Pressure transmitter
2 Pages
-
BZG - Zener Barrier
2 Pages
-
FKG - Pressure transmitter
8 Pages
-
FKE - Level transmitter
8 Pages
-
GS/GSX
2 Pages
-
SR2 series
2 Pages
-
TR/TA.02
2 Pages
-
TR/TA.01
2 Pages
-
GR/GA
2 Pages
-
(D)MLFK
2 Pages
-
AIRGAS
2 Pages
-
U series
2 Pages
-
Pressostat - Thermostat série F
16 Pages
-
P Series
16 Pages
-
SG
2 Pages
-
BVL/M/NT(I)
2 Pages
-
BEKA's range
182 Pages
-
GN 25000
2 Pages
-
GN 21000
2 Pages
-
GH 11000
2 Pages
-
GC 52500
2 Pages
-
GC 52100
2 Pages
-
fc-pn
48 Pages
-
fc-gc6rfbg
2 Pages
-
fc-fm
39 Pages
-
process transmitter FKC series
10 Pages
-
A3300-31/51
2 Pages