FKP - Pressure transmitter (direct mount type)
8Pages

{{requestButtons}}

Catalog excerpts

FKP - Pressure transmitter (direct mount type) - 1

FKP-5 Pressure transmitter (direct mount type) Span, range and overrange limit : ■ DATA SHEET The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20 mA signal. The transmitter utilizes the unique micromachined capacitive silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. ■ FEATURES 1. High accuracy ±0.10/o 0.1% accuracy is a standard feature. Georgin's microcapacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum inventory and design Electronics unit, local indicators and electronics housing are interchangeable among all ProcessX transmitters. 3. Minimum environmental influence The "Advance Floating Cell" design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 4. Georgin/HART® bilingual communications protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX. 5. Application flexibility Various options that render the ProcessX suitable for almost any process applications include : • Analog indicator at either the electronics side or terminal side, • Full range of hazardous area approvals, • Built-in RFI filter and lightning arrester, • 5 digit LCD meter with engineering unit, • Stainless steel electronics housing, • Wide selection of materials. 6. Programmable output Linearization Function Output signal can be freely programmable (Up to 14 compensated points at approximation). 7. Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43. 8. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. Functional specifications Type : FKH : Smart, 4-20 mA DC + Georgin/Hart® digital signal Service : Liquid, gas, or vapour. Lower range limit (vacuum limit) is : Silicone fill sensor : See Fig. 1 Fluorinated fill sensor: 66 kPa abs (500 mmHg abs) at below 60°C. Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal. Power supply : Transmitter operates on 10.5 to 45 V DC at transmitter terminals. 10.5 to 32 V DC for the units with optional arrester. FC-FKP-EN-24-07-2017 Subject to modification due to technical advances

Open the catalog to page 1
FKP - Pressure transmitter (direct mount type) - 2

Load limitation : see figure below Note) The load resistance varies with the upper limit of the saturation current [I max] E [V] -10.5 R [O] = (I max [mA]+0.9)x10-3 Note : For communication with HHC(1) (model : FXW), min. of 250 0 required. ■ Hazardous location : Refer to the package insert for safe use.

Open the catalog to page 2
FKP - Pressure transmitter (direct mount type) - 3

FKP-5 Pressure transmitter (direct mount type) ■ Zero/span adjustment : Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. g Damping : Adjustable from HHC(1) or local adjustment unit with LCD display. The time constant is adjustable between 0,06 to 32 sec. Zero elevation/suppression : -100% to +100% of URL. Normal/reverse action : Selectable from HHC(1). Indication : Analog indicator or 5 digit LCD meter, as specified ■ Burnout direction : Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog...

Open the catalog to page 3
FKP - Pressure transmitter (direct mount type) - 4

RFI effect : < 0,2% of URL for the frequencies of 20 to 1000 MHz and field strength of 10 V/m when electronic housing covers are on (Classification : 2-abc : 0,2% of span according SAMA PMC 33.1) Response time : (without electrical damping) Time constant : 0.08 seconds (at 23°C) Dead time : about 0.12 seconds Response time = time constant + dead time Mounting position effect : Zero shift, less than 0.1 kPa {1 mbar} for a 10° tilt in any plane. This error can be corrected by adjusting zero. (Double the effect for fluorinated fill sensors). No effect on span. Vibration effect : < ±0,25% of...

Open the catalog to page 4
FKP - Pressure transmitter (direct mount type) - 5

FKP-5 Pressure transmitter (direct mount type) CODE SYMBOLS _2_ K DESCRIPTION Type Smart, 4-20 mAdc + Georgin/Hart® digital signal Connections Process connection See digit 15 See digit 15 See digit 15 Electrical connection Range & wetted parts material Diaphragm material 0,08125/1,3 bar 0,08125/1,3 bar 0,3125/5 bar 0,3125/5 bar 1,875/30 bar 1,875/30 bar 6,25/100 bar 6,25/100 bar Indicator & Arrester Indicator SS 316L SS 316L / gold coat SS 316L SS 316L / gold coat SS 316L SS 316L / gold coat SS 316L SS 316L / gold coat Wetted parts None Analog, 0-100% linear scale Analog, Custom scale...

Open the catalog to page 5
FKP - Pressure transmitter (direct mount type) - 6

FKP-5 Pressure transmitter (direct mount type) OUTLINE DIAGRAM (unit : mm) WITH ANALOG INDICATOR WEIGHT: 1,7 KG (WITHOUT OPTION) ADD : - 0,5 KG FOR MOUNTING BRACKET - 2 KG FOR STAINLESS STEEL HOUSING OPTION MOUNTING BRACKET ■ FOR 2" PIPE (060 mm )

Open the catalog to page 6
FKP - Pressure transmitter (direct mount type) - 7

Pressure transmitter (direct mount type) Details "A" - Process connection

Open the catalog to page 7
FKP - Pressure transmitter (direct mount type) - 8

EMC Directive (2004/108/EC) All models of ProcessX series transmitters are in accordance with : •the harmonized standards : - EN 61326-1 : 2006 (Electrical equipment for measurement, control and laboratory use - EMC requirement). - EN 61326-2-3 : 2006 (Part 2-3 : Particular requirement - Test configurations, operational conditions and performance criteria for tranducers with integrated or remote signal conditioning). Emission limits : EN 61326-1 : 2006 Performance criteria : A : During testing, normal performance within the specification limits. B : During testing, temporary degradation or...

Open the catalog to page 8

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages