FKH - Absolute pressure transmitter
8Pages

{{requestButtons}}

Catalog excerpts

FKH - Absolute pressure transmitter - 1

FKH...5 Absolute pressure transmitter Liquid, gas, or vapour. Span, range, and overrange limit : ■ DATA SHEET The ProcessX absolute pressure transmitter (direct mount type) accurately measures absolute pressure and transmits proportional 4 to 20 mA signal. the transmitter utilizes the unique micromachined capacitive silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. ■ features 1. High accuracy 0.2% accuracy for all calibrated spans is the standard feature. Georgin's micro-capacitance silicon sensor assures this feature for all suppressed calibration ranges without additional adjustment. 2. Minimum inventory Electronics unit, communication module, local indicators and electronics housing are interchangeable among all ProcessX models. 3. Minimum environmental influence The "Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 4. Georgin/HART® bilingual communications protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX. 5. Application flexibility Various options that render the ProcessX suitable for almost any process applications include : • Analog indicator at either the electronics side or terminal side, • Full range of hazardous area approvals, • Built-in RFI filter and lightning arrester, • 5 digit LCD meter with engineering unit, • Stainless steel electronics housing, • Wide selection of materials. i Functional specifications Type : FKH : Smart, 4-20 mA DC + Georgin/Hart® digital signal Service : Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal. Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC for the units with optional arrester. 6. Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. FC-FKH-EN-12-12-2018 Subject to modification due to technical advances

Open the catalog to page 1
FKH - Absolute pressure transmitter - 2

FKH...5 Absolute pressure transmitter Note : For communication with HHC(1) (Model : FXW), min. of 250 W required. Hazardous locations : Refer to the package insert for safe use.

Open the catalog to page 2
FKH - Absolute pressure transmitter - 3

FKH...5 Absolute pressure transmitter Zero/span adjustment : Zero and span are adjustable either from the HHC(1) in Hart® or Georgin protocol. Zero is also adjustable externally from the adjustable screw. Damping : Adjustable from HHC(1) or local adjustment unit with LCD display. The time constant is adjustable between 0.06 to 32 sec. Zero elevation/suppression : 0 kPa abs to +100% of URL. Normal/reverse action : Selectable from HHC(1) Indication : Analog indicator or 5 digit LCD meter, as specified. An analog display may be mounted at the location of one or the other of the housing....

Open the catalog to page 3
FKH - Absolute pressure transmitter - 4

Overrange effect : Zero shift, 0.3% of URL for any overrange to maximum limit. Supply voltage effect : Less than 0.05% of calibrated span per 10 V. Update rate : 60 msec RFI effect : < 0,2% of URL for the frequencies of 20 to 1000 MHz and field strength of 10 V/m when electronic housing covers are on (Classification : 2-abc : 0,2% of span according SAMA PMC 33.1) Response time : (63,3% of output signal without damping) Time constant. 0.08 seconds (at 23°C) Dead time: about 0.12 seconds Response time = time constant + dead time Mounting position effect : Zero shift, less than 0.1 kPa for a...

Open the catalog to page 4
FKH - Absolute pressure transmitter - 6

FKH...5 Absolute pressure transmitter OUTLINE DIAGRAM (unit : mm)WITH ANALOG INDICA TOR ELECTRICAL CONNECTION 1,5 kg FOR STAINLESS STEEL HOUSING OPTION X, X2 X3 X4 X5 X6 X7 X8- X, X„ X12 X13 - X14 X15 F K «□ ODQiflDDm-O □

Open the catalog to page 6
FKH - Absolute pressure transmitter - 7

Absolute pressure transmitter

Open the catalog to page 7
FKH - Absolute pressure transmitter - 8

Performance criteria : A : during testing, normal performance within the specification limits. B : during testing, temporary degradation or less of function or performance which is self-recovering.

Open the catalog to page 8

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages