Functional Specifications
The FKE level transmitter is a smart device that provides a 4-20 mA DC signal with a Georgin/Hart® digital signal, suitable for measuring liquid, gas, or vapor levels. It operates under various static pressures and spans, with specific range limits for models FKE 2 to FKE 8. The design minimizes environmental influence by ensuring the span is greater than 1/40 of the maximum span.
Output and Power Supply
The transmitter outputs a 4 to 20 mA DC signal with a digital overlay and requires a power supply of 10.5 V to 45 V DC, with specific requirements for units with optional arresters.
Features
1. High Accuracy: Standard accuracy is 0.165%, with an optional 0.1% accuracy.
2. Design Flexibility: Interchangeable electronics and housing.
3. Environmental Protection: Advanced design reduces measurement errors.
4. Communication: Supports Georgin and HART® protocols.
5. Application Flexibility: Suitable for various applications with multiple options.
6. Programmable Output: Allows for customizable output linearization.
7. Burnout Current Flexibility: Adjustable burnout signal levels.
8. Dry Calibration: Reliable calibration without reference pressure.
Load Limitations and Hazardous Locations
Load resistance varies with saturation current. The transmitter is certified for use in hazardous locations with specific ATEX and IECEx parameters for explosion-proof and intrinsic safety installations.
Adjustments and Indications
Zero and span adjustments can be made via HHC or externally. Damping is adjustable, and the device supports both normal and reverse actions. It features analog or LCD indicators and selectable burnout directions.
Environmental and Material Specifications
The transmitter operates in ambient temperatures from -40 to +85°C, with specific limits for different options. It is made from materials like SS 316L, Hastelloy-C, and others, with environmental protection ratings of IP66/IP67.
Performance Specifications
Accuracy includes linearity, hysteresis, and repeatability. The device is stable for 10 years with minimal supply voltage effect. It has a fast update rate and is resistant to RFI effects.
Physical Specifications
Electrical connections are available in various standards, and process connections include options for different flange types. The transmitter is designed for durability and compliance with relevant directives.
Specifications
The document outlines specifications for transducers with integrated or remote signal conditioning, focusing on emission limits and immunity requirements. Emission limits are defined by EN 61326-1:2006, with specific frequency ranges and limits based on EN 55011/CISPR 11 standards. Immunity requirements are detailed with test values and performance criteria, referencing standards such as EN 61000-4-2 and EN 61000-4-3.
Emission Limits
- Frequency range 30 to 230 MHz: 40 dB (µV/m) quasi-peak, measured at 10 m distance.
- Frequency range 230 to 1000 MHz: 47 dB (µV/m) quasi-peak, measured at 10 m distance.
Immunity Requirements
- Electrostatic discharge: 4 kV (Contact), 8 kV (Air).
- Electromagnetic field: 10 V/m (80 to 1000 MHz), 3 V/m (1.4 to 2.0 GHz), 1 V/m (2.0 to 2.7 GHz).
- Rated power frequency magnetic field: 30 A/m.
- Burst: 2 kV (5/50 NS, 5 kHz).
- Surge: 1 kV line to line, 2 kV line to line.
- Conducted RF: 3 V (150 kHz to 80 MHz).
Performance Criteria
- A: Normal performance within specification limits during testing.
- B: Temporary degradation or loss of function, self-recovering during testing.
Level Transmitter Specifications
The FKE...5 level transmitter includes various options for connections, materials, and approvals for hazardous locations. It supports a smart 4-20 mAdc + Georgin/Hart digital signal.
Connections
- LP side connections: Options include 1/4-18 NPT, 7/16-20 UNF, M10, and others.
- Mounting flange materials and sizes vary, including SS 316L and ANSI/DIN standards.
Materials
- Options for process cover, diaphragm, and wetted sensor body materials include SS 316L, Hastelloy-C, Monel, Tantalum, and others.
Indicators and Arrester Options
- Various analog and digital indicators are available, with or without arresters.
Approvals for Hazardous Locations
- Includes ATEX, FM, CSA, and IECEx approvals for different configurations.
Special Applications and Fill Fluid
- Options for fill fluid include silicone oil, fluorinated oil, and sanitary fill fluid.
Weight and Design
- The weight ranges from 10.2 to 19.2 kg, with additional weight for options like flange, extension, and mounting brackets.
Diagrams
The document includes outline and connection diagrams for both short and long design configurations, detailing dimensions and connection types.
See more

Catalog excerpts

FKE - Level transmitter-1

FKE-5 Level transmitter ■ DATA SHEET The ProcessX level transmitter accurately measures liquid level and transmits a proportional 4 to 20 mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. ■ FEATURES 1. High accuracy 0.165% accuracy for all calibrated spans is a standard feature. The micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 0.1% accuracy is available as option. 2. Minimum inventory and design Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters. 3. Minimum environmental influence The "Advanced Floating Cell" design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 4. Georgin/HART® bilingual communications protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX. 5. Application flexibility Various options that render the ProcessX suitable for almost any process applications include : • Full range of hazardous area approvals, • Built-in RFI filter and lightning arrester, • 5-digit LCD meter with engineering unit, • Stainless steel electronics housing, • Wide selection of materials. 6. Programmable output Linearization Function Output signal can be freely programmable. (Up to 14 compensated points at approximation). 7. Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43. 8. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. Functional specifications Type : FKE : Smart, 4-20 mA DC + Georgin/Hart® digital signal Service : Liquid, gas or vapour Static pressure, span, and range limit : Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. Lower limit of static pressure (vacuum limit) : Silicone fill sensor : See Fig.1 Fluorinated fill sensor : 66 kPa abs (500 mmHg abs) at temperature below 60 °C. See fig.2 Overrange limit : To maximum static pressure limit. Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal. Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC for the units with optional arrester. FC-FKE-EN-24-07-2017 Subject to modification due to technical advances

 Open the catalog to page 1
FKE - Level transmitter-2

Note : For communication with HHC(1), min. of 250 0 required. Hazardous locations : See below Refer to the package insert for safe use.

 Open the catalog to page 2
FKE - Level transmitter-3

FKE-5 Level transmitter Zero/span adjustment : Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping : Adjustable from HHC(1) or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 sec. Zero elevation/suppression : -100% to + 100% of URL. Normal/reverse action : Selectable from HHC(1) Indication : Analog indicator or 5-digit LCD meter. Burnout direction : Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either "Output Hold", "Output...

 Open the catalog to page 3
FKE - Level transmitter-4

Response time : (At 63,3% of output signal without damping) Note : Gasket : Viton O-ring or PTFE/15% graphite square section gasket. Temperature effect : Effects per 28°C change between the limits of -40°C and +85°C Zero shift (transmitter only) : ±0,3 of URL Zero shift (level kit only) : +0,3 mbar/28°C Total effect (level kit and transmitter : ± 0,3% of URL Note : The indicated values are for temperature compensation made on transmitter only, without level kit. Zero shift is improved (2 to 3 times) by an additional temperature compensation of the complete level transmitter (level kit and transmitter)....

 Open the catalog to page 4
FKE - Level transmitter-5

Level transmitter Degreasing : Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Optional tag plate : An extra stainless steel tag with customer tag data is wired to the transmitter. Vacuum service : Special silicone oil and filling procedure are applied. See Fig.1 and Fig.2 below. NACE specification : Metallic materials for all pressure bound ary parts comply with NACE MR 0175/ISO 15156. SS 660 bolts and nuts comply with NACE MR 0175/ISO 15156. Silicone (Code Y,G) Operating area Operating pressure Operating pressure...

 Open the catalog to page 5
FKE - Level transmitter-6

CODE SYMBOLS 1- Turn down of 100 : 1 is possible, but it should be used at a span greater than 1/40 of the maximum span for better performance. 2- Add values for material options are for DN80 PN40 or ANSI-150 LB3" flange rate, DN100 or 4" add values are available upon request, LP side writed cell body diaphragm in exotic materials are available upon request. 3- All wetted parts in the same material (diaphragm, extension, flange gasket area). 4- When no code can be found in the current code symbols, place* in concerned code digit(s) & add* in 16 th digit. 5- Our stainless steel bolts/nuts in SS...

 Open the catalog to page 6
FKE - Level transmitter-7

FKE-5 Level transmitter OUTLINE DIAGRAM FOR SHORT DESIGN (unit : mm) ZERO/SPAN ADJUSTMENT FLUSHING RINGS DIMENSIONS

 Open the catalog to page 7
FKE - Level transmitter-8

OUTLINE DIAGRAM FOR LONG DESIGN (Unit : mm) WITH ANALOG INDICATOR WITH DIGITAL INDICATOR ELECTRICAL CONNECTION (SEE TABLE) LOW PRESSURE CONNECTION (SEE DETAIL A) FLUSHING RING (OPTION) FLUSHING RINGS DIMENSIONS Weight: 10.2 to 19.2 kg (without option) Add : - Flange’s weight (see table) - 1 kg per 50 mm of extension - 0.3 kg for indicator (option) - 2 kg for SS mounting bracket (option) - 0.5 kg for mounting bracket FLANGES DIMENSIONS ACCORDING TO EN 1092-1 & EN 1759-1

 Open the catalog to page 8

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2  Pages

  2. GP Serie

    2  Pages

  3. GS/GSX

    2  Pages

  4. SR2 series

    2  Pages

  5. TR/TA.02

    2  Pages

  6. TR/TA.01

    2  Pages

  7. GR/GA

    2  Pages

  8. (D)MLFK

    2  Pages

  9. AIRGAS

    2  Pages

  10. U series

    2  Pages

  11. P Series

    16  Pages

  12. SG

    2  Pages

  13. BVL/M/NT(I)

    2  Pages

  14. BEKA's range

    182  Pages

  15. GN 25000

    2  Pages

  16. GN 21000

    2  Pages

  17. GH 11000

    2  Pages

  18. GC 52500

    2  Pages

  19. GC 52100

    2  Pages

  20. GB 64000

    2  Pages

  21. fc-pn

    48  Pages

  22. fc-gc6rfbg

    2  Pages

  23. fc-fm

    39  Pages

  24. A3300-31/51

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.