Catalog excerpts
FKA-5 Absolute pressure transmitter Type ■ DATA SHEET The ProcessX absolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20 mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. ■ FEATURES 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature. 0.1% accuracy is available as option. 2. Minimum inventory and design Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters. 3. Minimal environmental impact The "Advanced Floating Cell" design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 4. Georgin/HART™ bilingual communication protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX. 5. Application flexibility Various options that render the ProcessX suitable for almost any process applications include : • Full range of hazardous area approvals. • Built-in RFI filter and lightning arrester. • 5 digit LCD meter with engineering unit. • Stainless steel electronics housing. • Wide selection of materials. 6. Programmable output Linearization Function Output signal can be freely programmable. (Up to 14 compensated points at approximation). 7. Burnout current flexibility ( under scale : 3.2 to 4,0 mA / over scale : 20.0 to 22,5 mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43. Functional specifications Type : FKA : Smart, 4-20 mA DC + Georgin/Hart® digital signal Service : Liquid, gas or vapour Span, range, and overrange Hmrt : Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal. Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC the units with optional arrester. FC-FKA-EN-24-07-2017 Subject to modification due to technical advances 8. Calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
Open the catalog to page 1FKA-5 Absolute pressure transmitter Load limitation : see figure below Note) The load resistance varies with the upper limit of the saturation current [I max] Note : A 250 0 load resistor is required to communicate with the FXW Portable Communicator. Hazardous location : Refer to the package insert for safe use.
Open the catalog to page 2Zero/span adjustment : Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping : (Adjustable from HHC communicator or LCD digital display) The time constant is adjustable between 0,06 to 32 seconds. Zero elevation/suppression : Zero can be elevated within the specified range limit of each sensor model. -100% to +100% of URL. Normal/reverse action : Selectable from HHC(1). Indication : Analog indicator or 5-digit LCD meter, as specified. Burnout direction : Selectable from HHC(1) If self-diagnostic detect transmitter...
Open the catalog to page 3Process-wetted parts material : Total effect : ±(0.15+0.1 U R L )% span Double the effects for material code "H" (7th digit in codes symbols). Overange effect : Zero shift : ±0.2% of URL for any overrange to maximum limit Supply voltage effect : Less than 0.005% of calibrated span per 1 V. Update rate : 60 msec Influence of radio interferences : < 0,2% of URL for the frequencies of 20 to 1000 MHz and field strength of 10 V/m when electronic housing covers are on (Classification : 2-abc : 0,2% of span according SAMA PMC 33.1). Response time : (at 63,3% of the output without electronic...
Open the catalog to page 4FKA-5 Absolute pressure transmitter Safety for Industrial Process 1- Turn down of 100 : 1 is possible, but it should be used at a span greater than 1/40 of the maximum span for better performance. 2- When no code can be found in the current code symbols, place* in concerned code digit(s) & add* in 16 th digit. 3- Process cover with PVDF insert with 1/2-14 NPT side process connection/no vent drain, other upon request - square section PTFE gasket. 4- Our stainless steel bolts/nuts in SS 660 are in conformity with the NACE MR 0175/ISO 15156. 5- Code "D & V" FM approval only possible with...
Open the catalog to page 5Absolute pressure transmitter outline diagram (unit : mm) With digital indicator With analog indicator Ovale flange screw (see table 1) Vent / drain High Pressure Connection 1/4 NPT Mounting bracket for Pipe Ø60 (2”)
Open the catalog to page 6FKA-5 Absolute pressure transmitter Weight: 3,5 kg (without option) 0,8 kg for indicator option 2 kg for stainless steel housing option 0,5 kg for mounting bracket
Open the catalog to page 7FKA-5 Absolute pressure transmitter CONNECTION DIAGRAM | (?) + -/CK- CK+ EMC Directive (2004/108/EC) All models of ProcessX series transmitters are in accordance with : •the harmonized standards : - EN 61326-1 : 2006 (Electrical equipment for measurement, control and laboratory use - EMC requirement). - EN 61326-2-3 : 2006 (Part 2-3 : Particular requirement - Test configurations, operational conditions and performance criteria for tranducers with integrated or remote signal conditioning). Emission limits : EN 61326-1 : 2006 Performance criteria : A : During testing, normal performance...
Open the catalog to page 8All GEORGIN S.A. catalogs and technical brochures
-
S5UI
2 Pages
-
GP Serie
2 Pages
-
GR/GA - Pressure transmitter
2 Pages
-
BZG - Zener Barrier
2 Pages
-
FKG - Pressure transmitter
8 Pages
-
FKE - Level transmitter
8 Pages
-
GS/GSX
2 Pages
-
SR2 series
2 Pages
-
TR/TA.02
2 Pages
-
TR/TA.01
2 Pages
-
GR/GA
2 Pages
-
(D)MLFK
2 Pages
-
AIRGAS
2 Pages
-
U series
2 Pages
-
Pressostat - Thermostat série F
16 Pages
-
P Series
16 Pages
-
SG
2 Pages
-
BVL/M/NT(I)
2 Pages
-
BEKA's range
182 Pages
-
GN 25000
2 Pages
-
GN 21000
2 Pages
-
GH 11000
2 Pages
-
GC 52500
2 Pages
-
GC 52100
2 Pages
-
GB 64000
2 Pages
-
fc-pn
48 Pages
-
fc-gc6rfbg
2 Pages
-
fc-fm
39 Pages
-
process transmitter FKC series
10 Pages
-
A3300-31/51
2 Pages