Introduction
This document provides an overview of pressure-temperature switches used in nuclear power plants, manufactured by Regulateurs Georgin. These switches are designed to meet the specifications required by Electricité de France (EDF) and other entities.
Certifications and Approvals
The switches are ISO 9001 certified and approved by EDF, qualified for use in thermal, nuclear, and hydraulic environments.
Equipment Specifications
Various types of switches are detailed, including gauge pressure, differential pressure, and temperature switches. Each type is qualified under specific standards, with safety categories and instructing parties outlined.
Applications and Use
These switches control and monitor pressure and temperature in nuclear power plants, designed for different rates, overpressures, and pulsations, with models for hazardous zones and explosion-proof requirements.
Selection Criteria
Switch selection is based on overpressure, pulsation, and environmental conditions, with examples provided for specific applications.
Electrical and Mechanical Characteristics
Switches feature microswitches with adjustable or fixed deadbands, manufactured by ABB Control and Honeywell, suitable for conventional and nuclear environments.
Conclusion
Regulateurs Georgin offers a range of adaptable pressure-temperature switches for various environments, emphasizing the importance of selecting the right switch based on operational requirements.
Qualification
K3 qualification is outlined for specific models, based on criteria like minimum deadband settings and seismic-proof compliance.
Manufacturing Characteristics
The housing and cover are made from Mazak metal with IP 66 weatherproof sealing. Internal mechanisms use bichromate cadmium plated steel, with angled electrical connections.
Nuclear and Standardized Finishes
Stainless steel screws and nitric passivation are used for nuclear environments, with helium sealing tests. Standardized finishes include anticorrosion protection.
Paint Finish
Different finishes are applied based on the environment, with specific colors for conventional and nuclear settings.
Mechanical Characteristics
Tables provide specifications for pressure switch types, including maximum pressures, setting ranges, and deadbands.
Principle of Operation
Pressure is applied to a ductile system, affecting an LP balance, with an RP spring for setpoint adjustments.
Use
Pressure switches are suitable for fluids compatible with the sensing component, with models certified for hazardous zones under ATEX directive 94/9/EC.
Overview
The document details technical specifications and guidelines for differential pressure and temperature switches, focusing on types DPB, DPHB, DMLB, DMPB, DMJBV, DMABV, and DMKBV.
Specifications
Pressure switches are bellows-actuated, handling pressures between -1 to 70 bar, certified for explosive environments. Temperature switches operate on the vapor pressure principle, suitable for -90 to +600°C.
Mechanical Characteristics
Devices feature Mazak metal housings with IP 66 sealing, and bichromate cadmium plated steel mechanisms.
Use and Applications
Switches are used for load loss monitoring and are suitable for hazardous zones, with models certified for nuclear environments.
Qualification and Standards
Certain models are K3 qualified, ensuring compliance with seismic-proof regulations.
Manufacturing and Material Details
Materials for sensing components include stainless steel and various rubbers, with specific paint finishes for different environments.
Components and Materials
Conventional environments use copper or stainless steel, while nuclear environments use stainless steel and Tombac.
Finishes
Nuclear finishes use stainless steel screws and Ethylene Propylene rubber seals, with specific paint finishes for different environments.
Installation
Guidelines include using molybdenum disulfide on threads and seam welding around the flange.
Explosion-Proof Housing
Designed to withstand explosions, suitable for hazardous zones, approved under ATEX directive 94/9/EC.
See more

Catalog excerpts

fc-pn-1

Direction de l’Equipement EDF - SEPTEN PRESSURE - TEMPERATURE SWITCHES FOR NUCLEAR POWER PLANTS

 Open the catalog to page 1
fc-pn-2

REGULATEURS GEORGIN Specific organisation of PHYSAD activity ALL EQUIPMENT SUBJECT TO SPECIAL SPECIFICATIONS REQUIRED BY L'ELECTRICITE DE FRANCE LA DELEGATION GENERALE DE L'ARMEMENT RAIL TRANSPORT, SNCF, RATP, VAL AND RELATED ENTITIES EDF QUALIFICATIONS SEE TABLE OVERLEAF All equipment for EDF (Thermal, Nuclear, Hydraulic, Transport, etc.) Project Co-ordinator: Project Co-ordinator: Assistant : After Sales Service : Boris LIBERGE Pascal BOITTIN Brigitte LEFEBVRE Olivier YSAMBERT

 Open the catalog to page 2
fc-pn-3

Gauge pressure switch Gauge pressure switch Temperature switch Explosion-proof gauge pressure switch Differential pressure switch SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SEPTEN SPH SEPTEN Temperature switch Gauge pressure switch Gauge pressure switch Differential pressure switch Differential pressure switch Gauge pressure switch Partially conv. + K3 Partially conv. + K3 Partially conv. + K3 Conventional + K3 Conventional + K3 Conventional + K3 INSTRUCTING PARTY Gauge pressure switch Gauge pressure switch Temperature switch Differential pressure switch Tight deadband temperature...

 Open the catalog to page 3
fc-pn-4

Manufacturer : PHYSAD DEPARTMENT 14-16 rue Pierre Sémard – B.P. 107 92323 CHATILLON Cédex Tél. : 01.46.12.60.00 – Fax : 01.47.35.93.98 To facilitate information searches according to the atmospheric environment : • Low rates • Restricted overpressure • Restricted pulsation • High rates • Overpressure • Pulsations • Average rates • Overpressure depending on model • Low pressures Device with bellows Device with tube or diaphragm Device with diaphragm Device with bellows Device with diaphragm Device With bellows PRESSURE • Low rates • Restricted pulsation DIFFERENTIAL • Average rates • Overpressure...

 Open the catalog to page 4
fc-pn-5

1.1 – 1.1.00 • Example Data 1300 MW Nuclear Power Station Version Please refer to file 1.1 - 1.1.02 for further information regarding this example. A pressure switch must ensure the stoppage of an air compressor in a sub-building by rising pressure. − − Other features of the chosen example: − Low rates, but with pulsation, − A maximum of 3 MPa (30 bar) static pressure, − Temporary overpressures : 5.5 MPa (55 bar). Selection Overpressures and pulsations require a diaphragm component. 2. A microswitch with adjustable deadband corresponding to the demand must be selected. 0.7 MPa (7 bar). 3. The...

 Open the catalog to page 5
fc-pn-6

1.1 – 1.1.00 • ELECTRICAL CHARACTERISTICS • Contact Codes 96 1: Microswitch with dry contacts, nitrogen sealed, adjustable deadband. Manufactured by ABB CONTROL. 98: While maintaining the electrical properties of contact 96, this version is used to reduce minimal deadband significantly in manufacturing . Deadband is fixed here. 16: Where a special E.D.F. (French electricity service) dispensation is supplied, GEORGIN can provide other contacts. Contacts Manufacturer Use REP 900 Conventional Environment (A) REP 900 Nuclear Environment (BC and UTC) REP 1300 and N4 Conventional Environment (A) REP...

 Open the catalog to page 6
fc-pn-7

PRINCIPLE Pressure (P) is applied to a ductile system (sensitive component) whose consecutive position variations effect an LP balance. The effort produced is balanced by an RP spring allowing the adjustment of the setpoint. Once the setpoint has been reached, the contact(s) detect the LP balance movement. All fluids compatible with the sensing component for relative static pressure between - 0.1 to 25 MPa (-1 to 250 bar). Low rates (4 requests/minute). Restricted overpressures. Specific − Use in hazardous zones - Explosion-proof material: "Certified as compliant with harmonised European standards...

 Open the catalog to page 7
fc-pn-8

1.1 – 1.1.01 QUALIFICATION The following groups are qualified as K3 (according to the E-N-M-EL/93-35-C): − − − This K3 qualification is attributed only where the following specifications are present: − − − The differential value (deadband) is set to minimum, The operating value is at least one deadband value away from the setting point (value displayed on the device), The seismic-proof fixing regulations, particularly those integrated by the manufacturer, have been complied with. MANUFACTURING CHARACTERISTICS • General − Housing and cover manufactured in Mazak metal, − Sealing: weatherproof to...

 Open the catalog to page 8
fc-pn-9

Stainless steel screws, Nitric passivation, Helium sealing test, Connection seal in Ethylene Propylene rubber (EP). Standardized Finish (UTO) − Stainless steel screws and anticorrosion protection, − Helium sealing test, − Connection seal manufactured in Ethylene Propylene rubber (EP). Paint Finish A (conventional environment) and UTO (Standardized version): blue housing with a grey cover according to GEORGIN standard. BC (nuclear environment): Blue decontaminable epoxy alloy. ELECTRICAL CHARACTERISTICS

 Open the catalog to page 9
fc-pn-10

MECHANICAL CHARACTERISTICS Maximum Acceptable Pressure in kPa (bar) Range Contact ID Code Minimum Deadband Maxi Deadband Top of Bottom of in kPa the range the range (bar) ≤ in kPa (bar) ≥ Partial References (1) Both ranges may also be manufactured in "absolute pressure switch" versions. (2) In the K and P ranges, maximum pressure is 1.3 MPa (13 bar) when equipped with a Tombac bellows and 1.5 MPa (15 bar) when equipped with a stainless steel bello

 Open the catalog to page 10
fc-pn-11

1.1 – 1.1.01 Type Bellow pressure switch B See the table describing mechanical characteristics HB Contacts (See the table describing electrical characteristics file 1.1 – 1.1.00) 96 98 92(1) ABB CONTROL Microswitch (Adjustable deadband) ABB CONTROL Microswitch (Fixed deadband) HONEYWELL Microswitch (Fixed deadband) RANGE See the table describing mechanical characteristics Sensing Component Materials Stainless steel Other Environment Conventional Nuclear Standardized Version Fixed deadband equivalent to 50% of code 96 microswitch minimum deadband List of standardized references P96 P96 P96 P96...

 Open the catalog to page 11

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2  Pages

  2. GP Serie

    2  Pages

  3. GS/GSX

    2  Pages

  4. SR2 series

    2  Pages

  5. TR/TA.02

    2  Pages

  6. TR/TA.01

    2  Pages

  7. GR/GA

    2  Pages

  8. (D)MLFK

    2  Pages

  9. AIRGAS

    2  Pages

  10. U series

    2  Pages

  11. P Series

    16  Pages

  12. SG

    2  Pages

  13. BVL/M/NT(I)

    2  Pages

  14. BEKA's range

    182  Pages

  15. GN 25000

    2  Pages

  16. GN 21000

    2  Pages

  17. GH 11000

    2  Pages

  18. GC 52500

    2  Pages

  19. GC 52100

    2  Pages

  20. GB 64000

    2  Pages

  21. fc-gc6rfbg

    2  Pages

  22. fc-fm

    39  Pages

  23. A3300-31/51

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.