Introduction
Georgin's F Series pressure and temperature switches are engineered for industrial applications, offering high vibration resistance and reliability in harsh environments. They are used in sectors such as energy generation, oil, shipbuilding, and chemical processing.
Working Principle
The switches function by applying pressure or temperature to a sensing element, which moves and acts on a flexible arm. This movement is counterbalanced by a spring to adjust the set point, with a second spring for differential functions.
Construction
Available in various housings, including standard, explosion-proof, and stainless steel, the switches feature different sensing elements like bellows and diaphragms. They are suitable for stable or pulsating processes, with temperature limits varying by material.
ATEX Equipment
Designed for explosive atmospheres, these switches offer intrinsic safety, increased safety, and explosion-proof options, certified for various gas and dust environments with specific temperature and installation requirements.
Electrical and Pneumatic Functions
Electrical contacts are SPDT type, with fixed or adjustable dead bands. Pneumatic functions include normally open or closed configurations, with materials and seals tailored for specific applications.
Certifications and Qualifications
The equipment complies with ATEX certifications, ensuring safety and reliability in hazardous environments.
Switch Types and Functions
  • Pressure Switches: Includes bellows-actuated, diaphragm-actuated, and Bourdon tube gauge pressure switches, each with specific ranges and dead band specifications.
  • Temperature Switches: Covers direct bulb and bulb-capillary temperature switches, detailing operational temperature ranges and dead bands.
  • Electrical Functions: Describes single and dual contact electrical functions with fixed or adjustable dead bands.
  • Pneumatic Functions: Details pneumatic functions and specific features, including housing materials.
Specifications
  • Pressure Ranges: Detailed for each switch type, with specific ranges for absolute, gauge, and differential pressure switches.
  • Dead Bands: Fixed and adjustable dead bands are specified for each switch type, with tables providing minimum and maximum values.
  • Materials: Information on materials used for connectors, bellows, and diaphragms, including options for stainless steel and other materials.
Installation and Use
  • Housing Options: Standard and explosion-proof housings are available, with compatibility details for different electrical functions.
  • Operational Guidelines: Recommendations for installation angles and conditions, especially for temperature switches.
  • Special Features: Options for degreasing, passivation, and helium testing for pressure switches.
Examples and Code Numbers
Examples of code numbers for different switch configurations are provided, illustrating how to specify and order the correct switch type based on application needs.
Specifications for Temperature Switches
Standard capillary lengths are 2 meters, with options for other lengths. Standard bulb sizes are Ø14 x 150mm in stainless steel and Ø10 x 150mm in copper, with variations for ambient operating temperatures.
Mounting Temperature Switches
Specific mounting conditions are required, using immersion pockets with capillary cable glands for bulb installation. Detailed dimensions for various bulb sizes and materials are provided.
Installation Recommendations
Thermostatic probes should be installed vertically with the capillary outlet at the top. Deviations from recommended angles can affect operation, with a recommended area of ±45° from the vertical axis.
Capillary Cable Gland and Protection
The capillary cable gland ensures tightness at the capillary outlet and is standard on certain models. Capillary protection is optional for drilled-through designs.
Dimensional Drawings
2D or 3D drawings are available upon request. Instrument mounting requires adherence to the assembly manual, with specific requirements for different housing types.
Certification and Compliance
The F series switches comply with Directive 94/9/EC for explosion risk areas, meet the Pressure Equipment Directive (PED) requirements, and offer SIL2 capability for functional safety. They also comply with TR CU/TR TS regulations and NACE standards.
Contact Information
Georgin's contact details are provided for further inquiries.
See more

Catalog excerpts

F serie - Pressure & temperature switches-1

Safety for Industrial Process Temperature switches OTHER SPECIFIC FEATURES ■ Compact industrial series ■ Harsh environment versions ■ Gauge, absolute or differential pressure control direct bulb or through capillary ■ Electrical contact or pneumatic signal output ■ Protection for areas involving an explosion risk (ATEX)

 Open the catalog to page 1
F serie - Pressure & temperature switches-2

Working principle Type of sensing element and connection Operating temperature limits Ambient operating temperature limits Storage temperature Equipment designed for EXplosive ATmospheres (ATEX) 5 Intrinsic safety Increased safety Explosion-proof safety Electrical or pneumatic functions 6 Electrical contact Electrical function Pneumatic function Gauge pressure switches: ranges and dead bands 10 Diaphragm-actuated gauge pressure switches Bellows-actuated gauge pressure switches Bourdon tube pressure switches Absolute and differential pressure switches: ranges and dead bands 11 Bellows-actuated...

 Open the catalog to page 2
F serie - Pressure & temperature switches-3

Introduction GEORGIN F Series PRESSURE SWITCHES and TEMPERATURE SWITCHES offer an extensive range of equipment suitable for the harshest operating conditions. The series is a justified choice whenever precision and reliability are necessary criteria. APPLICATIONS thermal or nuclear energy generation diesel engines, pumps and compressors the oil industry, from drilling to refining shipbuilding for merchant or military navy steam circuits, furnaces and burners natural or liquefied gas transport and storage rail transport braking safety gas, steam or hydraulic turbines water treatment Smooth articulation...

 Open the catalog to page 3
F serie - Pressure & temperature switches-4

Construction Types of housings Standard housing: zamak, aluminium cover, epoxy paint coating Explosion-proof housing (RTPF): AS10G aluminium, epoxy paint coating Polyester housing (FPP) 316L/1.4404 stainless steel housing (FPX) 316 stainless steel external screws and fittings IP 66 (IP68 available as an option) IP 56 (IP66 available as an option) for diaphragm-actuated gauge pressure switch in FML, FMS, FMT type standard housing as per EN 60 529 (IEC 529) External ground terminal Plumbing is performed directly using wires for FPP and FPX type instruments and requires a specific external kit for...

 Open the catalog to page 4
F serie - Pressure & temperature switches-5

Equipment designed for EXplosive ATmospheres (ATEX) The tables below enable you to ascertain the product certification according to the protection index (IP66 except for FML, FMS, FMT which are IP56 unless specially requested otherwise) and the required installation area. INTRINSIC SAFETY Principle: gold-plated contact for low current to be associated with an I.S. interface (see fc-rdn-fren) Housing: standard

 Open the catalog to page 5
F serie - Pressure & temperature switches-6

Electrical or pneumatic functions Electrical contact The electrical contacts used by Georgin are SPDT type. At rest, contact is established between C-NC. NO C Position above the threshold NC Position below the threshold According to the type of action (opening or closure of the electrical circuit), the electrical connection is made on the terminal block between C-NC or C-NO. Electrical functions Fixed dead band (1) Standard Adjustable dead band (2) Tight dead band Nitrogen sealed Expl. pr. (tight dead band) Nitrogen sealed Expl. pr. (tight dead band) 2 SPDT (3) (acting together) Adjustable lagging...

 Open the catalog to page 6
F serie - Pressure & temperature switches-7

Electrical or pneumatic functions Maximum breaking capacity (resistive load) Contact No. Cable inlets The instruments (with the exception of polyester, stainless steel housings & explosion-proof housing) have one M16 type cable inlet and are supplied with 1 or 2 cable glands 5 to 10 mm in diameter (standard and I.S. instrument). The instrument can also be supplied without cable inlets. Explosion-proof housings are supplied as standard with a 3/4’’NPT type cable inlet. Cable glands are available as an option. The choice of cable gland directly affects the certification, and could lead to the equipment...

 Open the catalog to page 7
F serie - Pressure & temperature switches-8

Diaphragm-actuated gauge pressure switch Bellows-actuated gauge pressure switch Bourdon tube gauge pressure switch Diaphragm-actuated differential pressure switch Bellows-actuated differential pressure switch Direct bulb temperature switch Bulb and capillary temperature switch Can only be associated with the electrical functions 60(C), 62(C), 160(C), 162(C), 170(C), 172(C) Stainless steel housing Single electrical function with fixed dead band Single electrical function with adjustable dead band Electrical function with 2 simultaneous contacts with fixed dead band* Electrical function with 2 simultaneous...

 Open the catalog to page 8
F serie - Pressure & temperature switches-9

Specific features Range and qualification of metal parts in contact with fluid The range information is detailed in the next 3 pages. Standard housing The information "X" denotes, according to the type of instrument, that the connector, bellows, Bourdon tube and the flange of the diaphragm-actuated instrument or the the thermostatic element are made of stainless steel. Explosion-proof housing In addition to the reference, we request you to specify for a pressure switch: - The type of connector (1/2’’GM, ¼’’NPTF, mounting on separator, etc.) - The diaphragm material if applicable (NBR, FKM or...

 Open the catalog to page 9
F serie - Pressure & temperature switches-10

Gauge pressure switches: ranges and dead bands Diaphragm-actuated GAUGE pressure switches 1 SPDT Range adjustable dead band ≤ fixed dead band ≤ Pulses or transient pressure surge 200 bar version available - Code changes to FPAS For P (X) range pressure switches equipped with change-overs 96 or 106, the range becomes: 1 to 10 bar The "L" and "H" columns give the min dead bands for set points in the Lowest or Highest part of the range. Bellows-actuated GAUGE pressure switches 1 SPDT Range Type fixed dead band ≤ adjustable dead band ≤ for autoclaves For pressure switches equipped with SPDT 96, 106...

 Open the catalog to page 10
F serie - Pressure & temperature switches-11

Absolute and differential pressure switches: ranges and dead bands Bellows-actuated ABSOLUTE pressure switches 1 SPDT Range (absolute) fixed dead band ≤ 10 16 adjustable dead band ≤ 62 96 34 For RPTF type pressure switches, the maximum pressure will be limited to 8 bar absolute Diaphragm-actuated Differential pressure switches 1 SPDT fixed dead band ≤ 10 16 adjustable dead band ≤ 62 96 34 Max. Stat. P dead min/max band (operating) ≥ mbar bar Bellows-actuated Differential pressure switches 1 SPDT Range Type fixed dead band ≤ 10 16 adjustable dead band ≤ 62 96 34 Max. Stat. P dead min/max band...

 Open the catalog to page 11

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2  Pages

  2. GP Serie

    2  Pages

  3. GS/GSX

    2  Pages

  4. SR2 series

    2  Pages

  5. TR/TA.02

    2  Pages

  6. TR/TA.01

    2  Pages

  7. GR/GA

    2  Pages

  8. (D)MLFK

    2  Pages

  9. AIRGAS

    2  Pages

  10. U series

    2  Pages

  11. P Series

    16  Pages

  12. SG

    2  Pages

  13. BVL/M/NT(I)

    2  Pages

  14. BEKA's range

    182  Pages

  15. GN 25000

    2  Pages

  16. GN 21000

    2  Pages

  17. GH 11000

    2  Pages

  18. GC 52500

    2  Pages

  19. GC 52100

    2  Pages

  20. GB 64000

    2  Pages

  21. fc-pn

    48  Pages

  22. fc-gc6rfbg

    2  Pages

  23. fc-fm

    39  Pages

  24. A3300-31/51

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.