Specifications
The pressure switch is designed for very low pressures and features a steel cover with a blue epoxy coating. It offers two housing options: standard IP20 and proof IP55, with the ATEX version automatically using the proof housing. The mechanism is made of zinc-plated steel, and the sensing element is a Buna N diaphragm. The flange is also zinc-plated steel, with a stainless steel option available upon request. The microswitch has a very tight dead band, with current ratings of 10A/250VAC or 0.4A/125VDC for switch 16, and 0.1A/24VDC for switch 16D, which is suitable for "IS" or PLC uses.
Technical Data
Accuracy is less than 10% in constant cycle and temperature. The process connection is ½" BSPM, with other options available on request. Electrical connections are made on the switch, with different outputs for IP20 and IP55 versions. The ambient temperature range is -10 to 60°C, process temperature range is -40 to 120°C, and storage temperature range is -20 to 70°C. The device must be mounted vertically with a horizontal diaphragm.
Certifications
The ATEX version is certified for intrinsic safety with marking Ex ia IIC T6 (-40°C
Pressure Ranges
For relative pressure, the range is -1.5 to 1 mbar with a maximum pressure of 300 mbar and a fixed dead band of ≤ 0.1 mbar. For differential pressure, the range is 0 to 2.5 mbar with the same maximum pressure and a fixed dead band of ≤ 0.2 mbar.
Applications
The pressure switch is used in ventilations, air or gas filter fouling, and unit heater flow.
Settings Procedure
1. Unscrew the freight locking screw from the process connection and let the switch rest for 24 hours in a vertical position with a horizontal diaphragm.
2. Open the cover using the upper knob.
3. Partially unscrew the locking kit to access the setting screw.
4. Mount the pressure switch on a suitable bench.
5. Perform three slow cycles of pressure increase to the approximate set point.
6. Apply the desired set point pressure and adjust the screw to operate the switch.
7. Repeat step 6 to verify the setting and adjust if necessary.
8. Tighten the locking plate and replace the cover.
Drawings and Electrical Connection
In case of factory presetting, electrical connections are made on terminal blocks, and steps 1 and 6 should be checked.
See more

Catalog excerpts

(D)MLFK-1

(D)MLFK Pressostat tres faibles pressions Pressure switch - very low pressures i Utilisation ■ Uses Ventilations, encrassement de filtres, flux d'aerothermes, Ventilations, air or gas filter fouling, unit heater flow, ... Couvercle Acier peint epoxy couleur bleu Etancheite Capot standard IP20 - (D)MLFK16(D)CX La version ATEX est obligatoirement avec capot etanche Mecanisme Acier zingue bichromate Element sensible Membrane perbunan Autres sur demande Flasque capteur Acier zingue Flasque inox sur demande Micro-contact 1 microcontact tres faible ecart Pouvoir de coupure Contact 16 10A/250VAC // 0.4A/125VDC Contact 16D pour utilisation en S.I. ou automate. Cover Steel with blue epoxy coating Tightness Standard housing IP20 - (D)MLFK16(D)CX The ATEX version is automatically with a proof housing Mechanism Zinc plated steel Sensing element Buna N diaphragm Others on request Flange Zinc plated steel Stainless Steel flange on request Microswitch 1 very tight dead band microswitch Current rating Switch nr 16 10A/250VAC // 0.4A/125VDC Reference Reference Pression differentielle / Differential pressure 0 / 2.5 mbar Precision Raccord process Raccord electrique Sortie electrique Version IP20 Version IP55 <10% a cycle et temperature constante /" GM Autres sur demande Sur le contact (voir schema au verso) Passe-fil P.E. laiton nickele (05,5-9,5mm) Accuracy <10% in constant cycle and temperature Process connection /" BSPM Others on request Electrical connection On the switch (see backside) Electrical output IP20 version Cable hole IP55 version Nickel plated brass cable gland T° ambiante T° du fluide T° de stockage Montage -10 a 60°C -40 a 120°C -20 a 70°C Local par 4 taraudages M4(x6) Position verticale membrane horizontale imperative ! Mounting Localy by 4 holes M4(x6) Vertical mounting - horizontal diaphragm only ! i Certifications Certifications VERSION ATEX Marquage Groupe Categorie Zones N° attestation Securite intrinseque Ex ia IIC T6 (-40°C<Ta<80°C) Ex iaD 22 II 1G/3D 0 - 1 - 2 22 (poussieres non conductrices) LCIE 01 ATEX 6008X 08 ATEX 6057X ATEX VERSION Marking Group Category Zones Certificate N° Intrinsic safety Ex ia IIC T6 (-40°C<Ta<80°C) Ex iaD 22 II 1G/3D 0 - 1 - 2 22 (Non conductive dust) LCIE 01 ATEX 6008X 08 ATEX 6057X FC-MLFK-FREN-10-12-2018 Subject to modifications due to technical advances / Soucieux d'ameliorer nos produits, nous nous reservons le droit de reviser sans preavis les caracteristiques de nos produits

 Open the catalog to page 1
(D)MLFK-2

Pressostat très faibles pressions Pressure switch - very low pressures Réglages / Settings 1. Dévisser la vis de bridage de transport située dans le raccord process de l’appareil et laisser reposer pendant 24 heures (position verticale/membrane horizontale) avant de procéder à l’étalonnage. 1. Unscrew the freight locking screw out of the process connection of the switch. Let the switch without any action during 24 hours (vertical mounting/horizontal diaphragm) before any presetting. 2. Ouvrir le boitier via la vis supérieure 1 (figure 2) du couvercle. 2. Open the cover via the upper knob 1 (figure...

 Open the catalog to page 2

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2  Pages

  2. GP Serie

    2  Pages

  3. GS/GSX

    2  Pages

  4. SR2 series

    2  Pages

  5. TR/TA.02

    2  Pages

  6. TR/TA.01

    2  Pages

  7. GR/GA

    2  Pages

  8. AIRGAS

    2  Pages

  9. U series

    2  Pages

  10. P Series

    16  Pages

  11. SG

    2  Pages

  12. BVL/M/NT(I)

    2  Pages

  13. BEKA's range

    182  Pages

  14. GN 25000

    2  Pages

  15. GN 21000

    2  Pages

  16. GH 11000

    2  Pages

  17. GC 52500

    2  Pages

  18. GC 52100

    2  Pages

  19. GB 64000

    2  Pages

  20. fc-pn

    48  Pages

  21. fc-gc6rfbg

    2  Pages

  22. fc-fm

    39  Pages

  23. A3300-31/51

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.