1. Catalogs
  2. GEORGII KOBOLD
  3. Asynchronous Motors KOD

Asynchronous Motors KOD

Asynchronous Motors KOD
1 / 16 PagesView full catalog

Asynchronous Motors KOD

Product catalog summary
Product Range Overview
The document provides a detailed overview of a wide range of servo motors and related components. This includes angular and planetary geared servo motors, three-phase synchronous and asynchronous motors, torque motors, brake motors, and both digital and analog servo drives. Key specifications highlighted are torque ranges, power ratings, and additional features such as brakes, encoders, and external fans.
Mechanical Specifications
This section details the mechanical specifications, including mounting standards, shaft height tolerances, construction types, flange accuracy, terminal box specifications, cooling methods, and bearing types. It references notable standards such as DIN and IEC, specifying tolerances and configurations for various motor types.
Electrical Specifications
The document covers electrical specifications, including regulations, voltage and frequency standards, and compliance with international guidelines. Motors are designed for standard voltages and frequencies, with options for different configurations to meet specific operational needs. Compliance with EU directives and CSA approval is emphasized.
Protection and Construction
Details on protection classes and construction are provided, including IP ratings for motors, switches, and external fans. The document specifies materials used for end shields and housings, as well as vibration intensity standards.
Additional Features
Additional features include rotor configurations for higher starting torque and CE labeling compliance. Detailed information on shaft end specifications and lubrication requirements for bearings is also provided.
Specifications
The document outlines motor specifications, including nominal voltage and frequency. It specifies that motors designed for 60 Hz should not be connected to a 50 Hz supply. The insulation class is F according to DIN VDE 0530, suitable for tropical climates, with optional reinforced moisture protection.
Performance
Motor ratings result in a temperature increase up to the thermal class B limit, despite using superior insulation materials of class F. Conditions according to DIN VDE 0530 apply, including installation below 1000 m altitude, ambient temperature below 40°C, and continuous operation mode S1.
Modes of Operation
For three-phase motors, important modes include continuous service S1, intermittent duty S3 and S4, with specific conditions for cyclic duration and inertia factor.
Service Factor
Motors are designed for high switch counts per hour. If operated in continuous mode S1 with no more than 5 cycles/hour, the rated power can be increased by the service factor listed in the type selection table.
Winding Protection
Available on request, includes thermal circuit breakers and thermistors to prevent overheating by opening switch contacts or triggering a device when the permissible temperature is exceeded.
Additional Features
Optional external fans for cooling are available for specific motor sizes, with electrical connections via plug and various voltage options. Motors can also be equipped with enclosed switches instead of terminal boxes, with protection class IP 54.
Type Designation
The structure of the type designation includes basic motor type, frame size, number of poles, and other specifications. Variants and auxiliary designations are available on request.
Technical Data Explanations
Includes definitions for rated speed, power, current, torque, power factor, efficiency, and other parameters.
Type Selection
Provides a detailed table of motor types with specifications such as speed, power, current, torque, and efficiency for different frame sizes.
Construction Types and Dimensions
Details various construction types and dimensions for motor installation.
See more

Catalog excerpts

Asynchronous Motors KOD-1

Three-phase asynchronous motors KOD Moteurs triphases asynchrones KOD

 Open the catalog to page 1
Asynchronous Motors KOD-2

-Bauprogramm Servo-Winkelgetriebemotoren und Servo-Planetengetriebemotoren Drehstrom-Servo-Synchronmotoren Torque-Motoren Drehstrom-Servo-Asynchronmotoren Servo- Synchron- und Asynchronmotoren in Edelstahlausführung Bremsmotoren / posistop-Motoren Drehstrom-Asynchronmotoren Drehfeldmagnete Gleichstrommotoren Getriebemotoren Planetengetriebe / Kegelradgetriebe Digitale Servoantriebe Analoge Kompakt-Servoregler Dezentrale Servoantriebe Digitale Frequenzumrichter Digitale Servo-Umrichter Drehmomentsteller Drehstrom-Servo-Synchronmotoren mit integrierten Servogetrieben 10 – 215 Nm / 3 - 115 Nm Stillstandsmoment...

 Open the catalog to page 2
Asynchronous Motors KOD-3

Three-phase asynchronous motors KOD Moteurs triphases asynchrones KOD Mechanische Ausfuhrung Mechanical data Execution mecanique Anbaunormen Mounting standards Normes de montage FuGmotor DIN 42673, Flanschmotor DIN Foot motor DIN 42673, Flange motor DIN Moteur normal DIN 42673, moteur a bride DIN 42677 in Ubereinstimmung mit der IEC- 42677 in accordance with the IEC- 42677 en conformite avec la publication IEC Publikation 72-1, CENELEC HD 231. Publication 72-1, CENELEC HD 231. 72-1, CENELEC HD 231. Achshohentoleranz Shaft height tolerance Tolerance verticale de I'arbre -0,5 mm nach DIN 747. -0.5...

 Open the catalog to page 3
Asynchronous Motors KOD-4

Schutzart Protection class Type de protection Nach IEC 34 T. 5 bzw. DIN VDE 0530 T. 5 According to IEC 34 T. 5 and. DIN VDE 0530 Selon IEC 34 T. 5 et/ou DIN VDE 0530 T. 5 Motor IP 54, auf Wunsch IP 55 Motor IP 54, on request IP 55 Moteur IP 54, IP 55 sur demande Schalter IP 54 Switch IP 54 Interrupteur IP 54 Fremdlufter IP 54, External fan IP 54, Ventilateur auxiliaire IP 54, Baugrolie 80 und 90 IP 55. Frame size 80 and 90 IP 55. Taille 80 et 90 IP 55. Wellenende Shaft end Bout d'arbre Nach DIN 748 T. 3, jedoch genauere Pas- According to DIN 748 T. 3, however, a more Selon DIN 748, partie 3,...

 Open the catalog to page 4
Asynchronous Motors KOD-5

crease in temperature). Intermittent duty S4...%, FI..., (a duty similar to S3, however with a noticeable warm-up time per cycle) The mode of operation is the cyclic duration (ED) in % and the additional inertia factor (FI) to be added with S4. beeinflusst). Aussetzbetrieb S4...%, FI..., (ein Betrieb wie S3, jedoch mit einer merklichen Anlaufzeit pro Spiel). Der Betriebsart ist die Einschaltdauer (ED) in % und bei S4 zusätzlich der Trägheitsfaktor (FI) anzufügen. Servicefaktor (thermische Reserve) Die elektrisch-magnetische Auslegung der Motoren entspricht einem Einsatz bei hoher Schaltzahl pro...

 Open the catalog to page 5
Asynchronous Motors KOD-6

Aufbau der Typenbezeichnung Structure of the type designation Structure de la désignation du type Beispiel • Example • Exemple Motorgrundtyp Basic motor type Type de base moteur Baugröße Frame size Taille Polzahl Number of poles Nombre de pôles Paketlänge in cm Length of stator laminations stack in cm Longueur de l’empilage en cm Änderungszustand Modification state État de la modification Varianten der Grundtype, auf Anfrage: W WK Variants of the basic type, on request: W WK Variantes du type de base, sur demande: W WK Wicklungsschutz (Öffner) Wicklungsschutz PTC Kaltleiter Winding protection...

 Open the catalog to page 6
Asynchronous Motors KOD-7

Type selection Motoren mit einer Drehzahl Motors with one speed Baugröße Frame Size Taille *) außer der IE2 Norm, nur für Ersatz der gleichen Motoren wenn Einsatz von KOD 649-A nicht möglich ist *) except the norm IE2, only for substitute of the same motors if application of KOD 649-A is not possible *) à part la norme IE2, seulement pour le dédommagement des mêmes moteurs si l'engagement du KOD 649-A n'est pas possible Motoren polumschaltbar 2 Drehzahlen, Dahlanderschaltung Δ/YY* Baugröße Frame Size Taille Pole-changeable motors 2 speeds, Dahlander pole-changing Δ/YY* Moteurs à commutation de...

 Open the catalog to page 7
Asynchronous Motors KOD-9

Typ KOD Type KOD Type KOD DIN/IEC Baugröße Frame Size Taille

 Open the catalog to page 9
Asynchronous Motors KOD-10

DIN/IEC Baugröße Frame size Taille Flansch IM B 5 Flange IM B 5 Bride IM B 5 1) M4 x 8,5 M5 x 11 M8 x 16,5 2) Flanschzuordnung A160 entspricht nicht DIN 42677 / Flange correlation A160 does not conform to DIN 42677 / L’affectation de la bride A160 n’est pas conforme à DIN 42677

 Open the catalog to page 10
Asynchronous Motors KOD-11

DIN/IEC Baugröße Frame Size Taille Flansch IM B 14 Flange IM B 14 Bride IM B 14 wahlweise optional au choix C 80 wahlweise optional au choix C 90 wahlweise optional au choix wahlweise optional au choix wahlweise optional au choix

 Open the catalog to page 11
Asynchronous Motors KOD-12

Motors with external fan Moteurs avec refroidissement par ventilation forcée DIN/IEC Baugröße Frame size Taille Motoren Bauform IM B 3 ohne Fuß Motors Construction Type IM B 3 without foot Typ KOD 325 425, 444-A 524, 526 Type KOD 328 465, 446-A 546-C, 548-C Type KOD 346-A 467 568, 588 DIN/IEC Baugröße 56 63 71 Frame size Taille a6 26 30 38 b6 43,1 55 67,3 s6 M4 M4 M5 w6 58,5 65 71 Fuß kann mittels 2 Befestigungsleisten angeschraubt werden: Foot can be screwed on with 2 attachment lasts: Le montant peut être vissé au moyen de 2 barres de fixation: KOD KOD 3.. KOD 4.. KOD 5.. KOD 6.. KOD 7.1 KOD...

 Open the catalog to page 12
Asynchronous Motors KOD-13

Motoren mit angebautem Schalter Motors with altered switch Moteurs avec interrupteur intégré On-off switch Motor Motor Moteur a b c d Commutateur disjoncteur Reverse gears Motor Motor Moteur a b c d Combinateur d’inversion Pole switch Motor Motor Moteur a b c d

 Open the catalog to page 13
Asynchronous Motors KOD-14

Varistor- Schutzbeschaltung Varistor protective circuit Câblage de protection varistor Vorteile Spannungsspitzen, die beim Schalten von Motorwicklungen auftreten, werden durch die zusätzliche Schutzbeschaltung wirksam begrenzt. Reduzierung der Spannungsspitzen auf ca. 1/3 des Wertes ohne Schutzbeschaltung. Schutz elektronischer Bauteile und Geräte, die über das Netz gefährdet sind (EMV- Störungen). Schutz der Motorisolation, insbesondere bei Betrieb des Motors am Frequenzumrichter und damit Verlängerung der Lebensdauer des Motors. Schutz der Motorisolation, bei hochpoligen Motoren und hoher Schalthäufigkeit....

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.