AFL

AFL

AFL

Product catalog summary
General Specifications
Type: AFL Illuminated Contact Block, Maintained
Series: Contact Blocks A...
Approvals: CCC, CSA, ENEC10, VDE, CE, UKCA, UR, DNV
Illumination: Yes
Operating Temperature: -30 °C to 70 °C (without illumination), -30 °C to 55 °C (incandescent), -30 °C to 65 °C (LED)
Enclosure Colour: Transparent
Contact Material: AgNi
Storage Temperature: -50 °C to 85 °C
Degree of Protection: IP00 (front)
Electrical Specifications
Conditional Short Circuit Current: 1000 A
Rated Operating Voltage: 240 V AC, 250 V DC, 125 V DC, 60 V DC, 24 V DC
Rated Operating Current: 3 A AC, 0.2 A DC, 0.4 A DC, 1 A DC, 2 A DC
Rated Insulation Voltage: 250 V AC/DC, 300 V AC/DC
Rated Impulse Withstand Voltage: 2.5 kV
Rated Current: 6(3) A
Contact Resistance: < 20 mΩ (NC/NO new state)
Electrical Lifetime: 1,000,000 switching cycles
Contact Type: 1NC, 1NO
Short Circuit Protection: SCPD 6 A Char. D
Illuminant Power: Max. 1.2 W
Illuminant Connection: X1 (anode), X2 (cathode)
Operating Voltage Illuminant: Max. 60 V
Bouncing Time: < 20 ms (NC), < 10 ms (NO)
Switching Capacity: 250 V AC/DC, 6 A
Thermal Continuous Current: 6 A AC
Note: Only NC contact may be used for safety circuit in emergency stop contactors as per EN 60947-5-1
Mechanical Specifications
Connection: Faston terminals 2.8 mm x 0.8 mm
Operating Travel: 6 mm
Mechanical Lifetime: 1,000,000 switching cycles
Switching Function: Latching function
Positive Opening: According to EN60947-5-1, appendix K
Technical Drawings
Includes dimensional drawing, circuit diagram, and switching path diagram.
See more

Catalog excerpts

AFL-1

04/15/2026 Technical data Illuminated contact block, maintained Series contact blocks A... Rubric Contact blocks Approvals CCC, CSA, ENEC10, VDE, CE, UKCA, UR, DNV * General data Illumination Operating temperature -30 °C ... 70 °C without illumination -30 °C ... 55 °C for incandescent lighting -30 °C ... 65 °C for LED illumination Enclosure colour Contact material AgNi Storage temperature -50 °C ... 85 °C Degree of protection front IP00 * Electrical data Conditional short circuit current 1000 A Rated operating voltage Georg Schlegel GmbH & Co. KG Kapellenweg 4

 Open the catalog to page 1
AFL-2

Rated operating current 3 A AC Rated insulation voltage 250 V AC Rated voltage 250 V AC/DC Rated impulse withstand voltage 2.5 kV Contact resistance < 20 mO NC new state Electrical lifetime 1,000,000 switching cycles Short circuit protection SCPD 6 A Char. D llluminant connection XI ...anode, X2...cathode Operating voltage illuminant max. 60 V Switching capacity 250 V AC/DC Thermal continuous current , . Note for emergency stop contactors . Only the NC contact may be used for the safety circuit for changeover contacts of the Za type as defined in EN 60947-51 Georg Schlegel GmbH & Co. KG ^ +49...

 Open the catalog to page 2
AFL-3

ߡ Mechanical data Connection Operating travel Mechanical lifetime Switching function Latching function Positive opening Technical drawings ڰߡ Dimensional drawing Georg Schlegel GmbH & Co. KG Kapellenweg 4 88525 Dڃrmentingen / Germany ڰߡ Switching path diagram

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.