Catalog excerpts
Genvolt design, develop and manufacture a wide range of high voltage power supply systems 8000 SeriesHigh Voltage PSU Specification Summary The Genvolt 8000 series is a rugged modularised range of AC-input DC High Voltage supplies, designed to operate from a universal mains input from 85VAC to 256VAC 50/60Hz. Power Output options from 1kV to 70kV. They feature an active boost-style Power Factor Correction front end - i.e. an active rectifier. This offers a very low harmonic distortion at mains frequencies with a power factor of up to 0.99. The modules have a FIXED polarity output which should be specified at the time ordering using the "Model Finder" table. They operate in both Voltage Control and Current Control modes with fast active crossover between the modes. Protection against output short circuits or arcs, over temperature and output overvoltage allow for operation in demanding environments Standard Features, as fitted at the factory Logic level for high voltage enable/disable An overvoltage protection circuit monitors the output for excessive voltage generation. Overvoltage conditions can be caused by excessive input program signal. If an overvoltage condition is detected, the power supply is latched off until input power is reset. A PS fault indicator and a PS fault output on J1, indicate an OVP or a regulation error. The input voltage of the 8000 can operate within the range from 85VAC to 265VAC. The power factor is actively corrected across the entire range and is better than 0.99 at full load. An internal EMI filter and fuse provide protection against line voltage surges and power supply faults. Specification Control Overvoltage Protection PS Fault Condition PF and Universal Input Internal EMI Filter AC input voltage range Power Factor Output Polarity Voltage Load Regulation Voltage Line Regulation Current load regulation Current line regulation Voltage ripple Current stability Temperature coefficient Temperature Interlock Circuit Protection Relative Humidity 85VAC to 256VAC, 47 - 63 Hz FL 0.99 NL 0.98 +ve or -ve (Please specify when ordering) 0.01% of full voltage for a no load to a full load change +/- 0.005% of full voltage over the specified input voltage range 0.01% from 0V to full voltage +/- 0.01% of full current over the specified input voltage range per 8 hours after 0.1% p-p of output voltage 0.02% per 8hrs after Yihr warm up 100 ppm per °C Operating 0°C to 45°C Storage -20°C to +85°C Open Interlock will shut down unit Overvoltage, Overcurrent, Arcing and Over temperature Non condensing The control signal is NOT a safety interlock and must NOT be used for a protection system from high voltage generation for safety purposes. Remote Operating Features Remote Programming Remote Monitor High Voltage Enable / Disable +10VDC Reference Allows remote adjustment of the output voltage and current, via an external voltage source. Allows remote monitoring of the output voltage and current. Allows remote ON/OFF control of the high voltage. A +10VDC is provided for remote programming via a potentiometer or voltage divider. Genvolt Ltd, New Road, Highley, Bridgnorth, Shropshire, WV16 6NN, UK. T: +44(0)1746 862555 F: +44(0)1746 862666 E: info@genvolt.co.uk W: www.genvolt.co.uk Registered in England and Wales N° 8087238
Open the catalog to page 1Genvolt design, develop and manufacture a wide range of high voltage power supply systems Mechanical details Model specific, approximately 3Kg 95.25mm (H) x 127mm (W) x 279.4mm (D) IEC320 with mating connector x 2 Metres Proprietary HV Connector 15 pin 'D' connector (Male) Weight Dimensions Power input connector HV output connector Control interface connector Typical Applications Include: • Electrospinning & Electrospraying • X-ray generation • Insulation Testing • Capacitor charging (Contact Genvolt for individual Regulatory Approvals • Compliant to 2004/108/EC, the EMC directive •...
Open the catalog to page 2All Genvolt catalogs and technical brochures
-
EB04
5 Pages
-
XRG
4 Pages
-
AF01 Model
3 Pages
-
Pegasus P1800 Range
5 Pages
-
Pleiades
7 Pages
-
Pegasus P600/P900 Range
3 Pages
-
Sirius 1
11 Pages
-
Europa Range
1 Pages
-
7XX30 Model
2 Pages
-
ESK1
2 Pages