Gentos Measurement & Control Co., Ltd. Gentos Measurement & Control Co., Ltd. 12/F, BlockA5. Nanshan Ipark, No.1001 College Rd. Nanshan District, 518055,Shenzhen, China Tel: 86-755-2674 5999 ext. 8036 Fax: 86-755-26745333 E-mail: tanya@gentos.com.cn Website: www.pflowmeters.com
Open the catalog to page 1Product Overview F2 adopts the ultrasonic transit time measurement principle, combined with Gentos patented flow algorithm technology, it realizes accurate measurement of the fluid flow in the pipe. The product is allin-one and clip-on structure design, which is simple and convenient to install. Only four steps are needed all along. The installation process requires no contact with fluidmediaandno need to shut down the flow. This product is suitable for measuring pure water, softened water, and recycled water. It is particularly suitable for embedded use in water treatment application...
Open the catalog to page 2The ultrasonic flow sensor adopts the Transit Time measurement principle. It uses an ultrasonic signal from the transducer to travel in a flowing fluid, the velocity of sound wave increases parallel to the flow direction and decreases opposite to the flow direction.The transmission times are different at the same propagation distance, the flow rate of the fluid is measured according to the relationship between the difference of the transit time and the flow rate of the measured fluid. The flow velocity of the fluid is different at different locations within the pipe, the flow rate in the...
Open the catalog to page 3Selection Sample: Model: F2-1-DN20 Description: Model F2 with RS485 and 4~20mA outputs, applied to pipe siza DN20, PVC pipe.