Clamp-on Ultrasonic Flow Meter P118i
8Pages

{{requestButtons}}

Catalog excerpts

Clamp-on Ultrasonic Flow Meter	P118i - 1

Ultrasonic Portable Series Clamp-on Ultrasonic Flow Meter P118i Gentos Measurement & Control Co., Ltd.

Open the catalog to page 1
Clamp-on Ultrasonic Flow Meter	P118i - 2

A BOUT P118 i F EATURES AND CASES P118i Portable Ultrasonic Flowmeter enables the user to do flow measurement checks at many points in a flowprocess without the need for a permanent installation. This ultrasonic flowmeter adopts Gentos unique PICOFLY t i m e m e a s u re m e nt te c h n o l o g y, w h i c h co u l d m ake t h e resolution reach to 10 picoseconds (0.01 nanosecond). It realizes the high respondence and high accuracy ultrasonic measurement technology and application. Comparing with other traditional flowmeter or ultrasonic flowmeter, it has distinctive features such as high...

Open the catalog to page 2
Clamp-on Ultrasonic Flow Meter	P118i - 3

ABOUT P118i-SPECIFICATION PERFORMANCE SPECIFICATIONS NEMA13 ( IP54 ). Encapsulated design, IP68; Standard cable length: 5m. Transmitter:approximately1.0kg.

Open the catalog to page 3
Clamp-on Ultrasonic Flow Meter	P118i - 4

ABOUT P118i-INTERFACE AND SIZE WIRING DIAGRAM Downstream Upstream Transducer Transducer Power Switch Recharge Port Transducer | Rate | [ Velocity [ Signal | Total | [lom/To^ [ Diag Data H 3 ^

Open the catalog to page 4
Clamp-on Ultrasonic Flow Meter	P118i - 5

A BOUT P118 i T RANSDUCER I NSTALLATION M ETHODS V method measuring pipe size : 50mm-400mm Side View Section Transducer Upstream Transducer Downstream Transducer Pipe Strap Transducer space Z method measuring pipe size: 25mm-1200mm Side View Section Transducer Upstream Transducer Downstream Transducer Pipe Strap Transducer space

Open the catalog to page 5
Clamp-on Ultrasonic Flow Meter	P118i - 6

STRAIGHT LENGTH OF UPSTREAM PIPING STRAIGHT LENGTH OF DOWNSTREAM PIPING When selecting a measurement site, it is important to select an area where the fluid flow profile is fully developed to guarantee a highly accurate measurement. Use the following guidelines to select a proper installation site: Choose a section of pipe that is always full of liquid, suchasa vertical pipe with flow in the upward direction or a full horizontal pipe. Ensure enough straight pipe length at least equal to the figure shown below for the upstream and downstream transducers installation. Ensure that the pipe...

Open the catalog to page 6
Clamp-on Ultrasonic Flow Meter	P118i - 7

ABOUT P118i-ORDERING INFORMATION MODEL DESCRIPTION P118i Portable Ultrasonic Flowmeter Installation method: Handheld 8G SD card high memory data logging, maximum memorize 512 days data. Flow Range: ±0.03 ft/s ~ ±40 ft/s (±0.01 m/s~ ±12 m/s) Accuracy: ±0.5% Repeatability: 0.1 % Output: 4-20mA Internal lithium power supply: 10hours Pipe size range: 0.6"~48"(15mm~6000mm) Transducer: IP54, CP magnet portable transducer, 5m cable CODE TYPE OF TRANSDUCERS CODE TRANSDUCER CABLE LENGTH 016 CODE TRANSDUCER CABLE LENGTH 010 PH type of cable ,Standard 10ft (3m) CODE TYPE OF TEMPERATURE SENSOR...

Open the catalog to page 7
Clamp-on Ultrasonic Flow Meter	P118i - 8

Gentos Measurement & Control Co., Ltd. 12/F, Block A5. Nanshan Ipark, No.1001 College Rd. Nanshan District. Shenzhen, China Tel: 86-755-26745561 Fax: 86-755-26745333 E-mail: hola@gentos.com.cn We b: www.pflowmeters.com

Open the catalog to page 8

All Gentos catalogs and technical brochures