Clamp-on Ultrasonic Flow Meter D116
8Pages

{{requestButtons}}

Catalog excerpts

Clamp-on Ultrasonic Flow Meter D116 - 1

I Clamp-on Ultrasonic Flow Meter D116

Open the catalog to page 1
Clamp-on Ultrasonic Flow Meter D116 - 2

ABOUT D116-FEATURES AND CASES D116 Series Ultrasonic Flowmeter is a state-of-the-art universal transit-time flowmeter designed using FPGA chip and low-voltage broadband pulse transmission. Comparing with other traditional flowmeter or ultrasonic flowmeter, it has distinctive features such as high precision, high reliability, high capability and low cost, the flowmeter features other advantages: • TCT technology designed. • Less hardware components, low voltage broadband pulse transmission, low consumption power. • Clear, user-friendly menu selections make flowmeter simple and convenient to...

Open the catalog to page 2
Clamp-on Ultrasonic Flow Meter D116 - 3

PERFORMANCE SPECIFICATIONS PHYSICAL SPECIFICATIONS Transmitter Transducer Transducer cable Weight

Open the catalog to page 3
Clamp-on Ultrasonic Flow Meter D116 - 4

ABOUT D116-INTERFACE AND SIZE WIRING DIAGRAM

Open the catalog to page 4
Clamp-on Ultrasonic Flow Meter D116 - 5

SECTION Transducer Pipe Strap TRANSDUCER INSTALLATION METHODS V METHOD MEASURING PIPE SIZE : 25MM-400MM SIDE VIEW Upstream Transducer Downstream Transducer Top View Transducer space Z METHOD MEASURING PIPE SIZE: 100MM-3000MM

Open the catalog to page 5
Clamp-on Ultrasonic Flow Meter D116 - 6

When selecting a measurement site, it is important to select an area where the fluid flow profile is fully developed to guarantee a highly accurate measurement. Use the following guidelines to select a proper installation site: Choose a section of pipe that is always full of liquid, such as a vertical pipe with flow in the upward direction or a full horizontal pipe. Ensure enough straight pipe length at least equal to the figure shown below for the upstream and downstream transducers installation. STRAIGHT LENGTH OF UPSTREAM PIPING 90° Bend STRAIGHT LENGTH OF DOWNSTREAM PIPING Tee Ensure...

Open the catalog to page 6
Clamp-on Ultrasonic Flow Meter D116 - 7

Standard Model: D116-4-CP037-030 Description: standard flowmeter with Clamp-on transducers CP037, OCT pulse/ Relay/4-20mA/ RS485, 9m cable. 6 page

Open the catalog to page 7
Clamp-on Ultrasonic Flow Meter D116 - 8

Gentos Measurement & Control Co., Ltd. 12/F, BlockA5. Nanshan Ipark, No.1001 College Rd. Nanshan District. Shenzhen, China Tel: 86-755-26745999 Fax: 86-755-26745333 E-mail: business@gentos.com.cn Find our website with Google search: www.pflow.com.cn

Open the catalog to page 8