Catalog excerpts
Conductivity Sensors Conductivity Sensors Type ICS PPSU Inline Conductivity Sensor ICS the new inline conductivity sensor from AVS-Römer Inline conductivity sensor for conductivity measurement of liquid media. The ceramic conductivity measuring cell in conjunction with the established ELSA push-in connectors made of PPSU finds its use primarily in the food industry. Push-in Fittings Other features: • minimal dead space • temperature-compensated evaluation electronics • materials and constructional design especially optimised for food applications Variations / options: • other material for seal The integrated sensor electronics are temperature-compensated. CHARACTERISTICS GENERAL Constructional design Product name Product type Nominal diameter Connection Ambient temperature Medium temperature Medium viscosity Body material Measuring cell material O-ring material Mounting method Mounting position Approval Ceramic conductivity measuring cell Conductivity Sensor ICS-958P3-... DN 4 ELSA push-in connectors for pipe/tube OD 6 0 °C to +60 °C 0 °C to +140 °C up to approx. 35 mm2/s PPSU (KTW approved, NSF certified) Al2O3, Pt, glass FKM (FDA-compliant) or EPDM (FDA complaint, KTW approved, NSF certified) using spring clip, internal width Ø 30-32 (not included in scope of supply) Preferably upright NSF/ANSI 169 PNEUMATIC - HYDRAULIC PN 16 Technical vacuum up to maximum allowable operating pressure OP in accordance with the specification table Kv-value in accordance with the specification table Gases or liquids which do not corrode the materials specified Nominal pressure Pressure range Flow rate Medium ELECTRIC Supply voltage Conductivity output signal Temperature output signal Electrical connection Protection class 9 to 36 V DC 0 to 5 V DC (linear over the entire measurement range) 0 to 5 V DC (linear over the entire measurement range) 4-pole screened cable 0.75 m (LiYCY 4xAWG24) IP65 MEASURING CELL Measuring range Accuracy Temperature error Response time Caution! PPSU should not be used in contact with aromatic hydrocarbons, oxidising acids, acetone, chlorinated hydrocarbons, ethers or ketones! Also, PPSU should not be placed directly in contact with anaerobic adhesives! AVS Römer . www.avs-roemer.de . info@avs-roemer.de . +49 8552 40
Open the catalog to page 1Conductivity Sensors Conductivity Sensor - Type ICS Illustration Home Product group PN Max. Allow. OP at ambient temp. 16 Tmin 0 °C, Tmax +60 °C black brown red orange yellow Plastic PPSU Allow. OP [bar] at medium temp. 20 °C 100 °C 140 °C Supply voltage Supply earth Temperature output signal Conductivity output signal Cable screen Kv-value water [l/min] EPDM (FDAcompliant) Order number Seal material Grip ring stainless steel 1.4310 Retaining ring stainless steel AISI 316L Conductivity L in mS/cm (reference temperature 25 °C) 5 Release ring PPSU natural Characteristic Curve 0-20 mS/cm or...
Open the catalog to page 2All Genn Dih catalogs and technical brochures
-
AD8/AD9
2 Pages
-
PLD
2 Pages
-
Non-Invasive Flow Sensor
2 Pages
-
IPS
2 Pages
-
ITS
2 Pages
-
ETV
9 Pages
-
PPV
6 Pages
-
CPV
6 Pages
-
APV
3 Pages
-
QKL-B4H
5 Pages
-
QKL-B1S.B2S/QKL-B3H
7 Pages
-
QKL-B1H
4 Pages
-
Miniature Proportional Valve
4 Pages
-
The Clippard Advantage
100 Pages
-
DIRECTIONALCONTROLVALVES
70 Pages
-
SC Sériés Cylinder
8 Pages