Quick Opening Valve (Series 4000)
2Pages

{{requestButtons}}

Catalog excerpts

Quick Opening Valve (Series 4000) - 1

QUICK OPENING VALVE 1/8” & 1/4” NPT 125 Psig (8.6 Bar) The Series 4000 Quick Opening Valve functions as in-line on-off switch particularly suited to applications in Instrumentation and Control Panels to open and close circuits or isolate gauges. The unique design of these valves permits full-closed to full-open operation quickly with a 60° turn of the knob. Standard units will detent in the selected position or, if desired, can be spring loaded (Option R) to return to the off position when released. The Series 4000 is offered in 2-way and 3-way designs. The 2-way design is a snap action on-off control, while the 3-way design offers the same snap on-off action while venting the downstream pressure to atmosphere when in the off position. These valves are compact in size and can be utilized for in-line and panel mount applications. Valves can be ordered Cleaned and Packaged for Oxygen service. Technical Data Max Operating Pressure: 125 Psig (8.6 Bar) Temperature Range: -20°F to 300°F (-29°C to 149°C) Flow Coefficient (Cv): 0.5 2-Way or 3-Way (vents downstream to atmosphere thru 3/32” orifice) Configurations 100% Factory Tested for Bubble Tight Shut Off Optional Spring Return to Close Standard Panel Mount: • Supplied with “Off – On” Aluminum Indicator Plate (1/16” thick, 1-5/8” diameter) and Panel Nut • 5/8” Panel Hole • 5/32” Maximum Panel Thickness Model Q-45 Materials of Construction Component Body, Stem, Housing, Bonnet, Valve Seat, Valve Cup, Rollers, Locknut Knob Indicator Plate Spring Roller Pin Set Screw Valve Seal, O-Ring Material Brass, ASTM B16 Thermosetting Phenolic Aluminum 17-7 SS, ASTM A313 Hardened Steel Steel (Black Oxide) FKM

Open the catalog to page 1
Quick Opening Valve (Series 4000) - 2

QUICK OPENING VALVE R – Snap Return to Off X – Cleaned and Packaged for Oxygen Service Q – 2 Way Quick Opening Valve QE – 3 Way Quick Opening Valve (Exhausts downstream pressure to atmosphere) PIPE SIZE (NPT) 41 - 1/8" Female x Female 42 - 1/8" Male x Male 43 - 1/8" Male x Female 44 - 1/4" Female x Female 45 - 1/4" Male x Male 46 - 1/4" Male x Female PROPER COMPONENT SELECTION – When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment...

Open the catalog to page 2

All Generant catalogs and technical brochures