1. Catalogs
  2. Generant
  3. Cylinder Check Valve

Cylinder Check Valve

Cylinder Check Valve

Cylinder Check Valve

Product catalog summary
Description
The Cylinder Check Valve is designed for use on the gas outlet of industrial cryogenic liquid cylinders to prevent backflow. It features an optional 'Tamper Evident Restraint' for visual indication of tampering. Available in CGA 540 and 580 configurations.
Features
  • Compact, rugged one-piece body construction
  • Optional 'Tamper Evident Restraint' with lock wire and lockout tag
  • High flow design exceeding maximum cylinder output
  • Supplied cleaned and bagged for Oxygen Service
  • 100% factory tested for leakage
  • GLT Low Temperature Viton™ Seal
Technical Data
  • Nominal Crack Pressure: 1 Psig (0.07 Bar)
  • External Leakage: Zero leak
  • Internal Leakage: Zero leak at 0.5 PSIG (0.03 bar) Back Pressure
  • Cv (flow coefficient): 0.65
  • Maximum Pressure: 3000 PSIG @ 150° F (206 bar @ 66° C)
  • Proof Pressure: 5,000 PSIG (345 bar)
Materials of Construction
  • Body, Poppet, Seat Insert, Seat Locking Screw: Brass, ASTM B16
  • Spring: Phosphor Bronze, ASTM B159
  • O’Ring Seal: GLT Viton™ (Lubricated with Krytox™ GPL-205)
Ordering Information
  • Tamper Evident Option: T – Tamper Evident (omit if not required)
  • Series: OPC – One Piece Check
  • Inlet Port: 3 – 3/8" Male NPT, 4 – 1/2" Male NPT
  • Crack Pressure: 1 – 1 PSI Nominal
  • Seal: V – GLT Viton™
  • Outlet Port: 540 – CGA 540 Connection, 580 – CGA 580 Connection
Proper Component Selection
When specifying a component, consider the total system design to ensure safe and trouble-free performance. The system designer is responsible for intended component function, materials compatibility, pressure ratings, installation, environment, and maintenance.
See more

Catalog excerpts

Cylinder Check Valve-1

CYLINDER CHECK CYLINDER CHECK VALVE 3/8" - 1/2" NPT x CGA 540 or 580 0-3000 PSIG Description The Cylinder Check Valve is used on the gas use outlet of industrial cryogenic liquid cylinders to prevent back flow into the cylinder. The optional “Tamper Evident Restraint” provides a visual indication if removal of the connection has been attempted. Available in CGA 540 & 580 configurations. Features • Compact and rugged one piece body construction • Optional “Tamper Evident Restraint” - lock wire and lockout tag • Provides visual evidence of compliance • High flow design exceeds maximum cylinder output • Supplied cleaned and bagged for Oxygen Service • 100% Factory Tested for leakage • GLT Low Temperature Viton™ Seal Technical Data • Nominal Crack Pressure: 1 Psig (0.07 Bar) • External Leakage: Zero leak • Internal Leakage: Zero leak at 0.5 PSIG (0.03 bar) Back Pressure • Cv (flow coefficient): 0.65 • Maximum Pressure: 3000 PSIG @ 150° F (206 bar @ 66° C) • Proof Pressure: 5,000 PSIG (345 bar) Materials of Construction Component Body, Poppet, Seat Insert, Seat Locking Screw Spring Phosphor Bronze, ASTM B159 O’Ring Seal* *Lubricated with Krytox™ GPL-205

 Open the catalog to page 1
Cylinder Check Valve-2

CYLINDER CHECK VALVE Ordering Information OPC – 3 540 – V - 1 – T TAMPER EVIDENT T – Tamper Evident Note: Omit if not required SERIES OPC – One Piece Check CRACK PRESSURE 1 – 1 PSI Nominal Note: Only available in 1 PSI Crack Pressure INLET PORT 3 – 3/8" Male NPT 4 – 1/2" Male NPT Note: Port Threads into Outlet of Gas Use Shut-Off Valve OUTLET PORT 540 – CGA 540 Connection 580 – CGA 580 Connection Note: VitonTM and KrytoxTM are trademarks of DuPont. PROPER COMPONENT SELECTION – When specifying a component, the total system design must be considered to ensure safe and trouble-free performance....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.