1. Catalogs
  2. Generant
  3. Cryogenic Relief Valve Brass (CRV)

Cryogenic Relief Valve Brass (CRV)

Cryogenic Relief Valve Brass (CRV)

Cryogenic Relief Valve Brass (CRV)

Product catalog summary
Description
The Generant Series Brass CRV is a cryogenic relief valve designed for overpressure protection in cryogenic systems. It features a 'Dirt Guard' to handle particulate contamination and is suitable for 'Blocked Line Safety'. The valve is factory preset with pressures from 10 to 750 Psig (0.7 to 51.7 Bar) and cannot be adjusted in the field. It offers high flow rates with minimal pressure accumulation and can discharge to the atmosphere or a downstream connection. Seals are made of Fluorosilicone for pressures 10-49 Psig and PCTFE for 50-750 Psig.
Features
  • CE marked according to PED 97/23/EC.
  • Incorporates a 'Dirt Guard' for extended valve life.
  • High flow capacity and excellent reseal performance.
  • Factory preset and permanently locked for tamper-proof service.
  • Discharge options include atmosphere or inline piping configurations.
  • Optional deflector cap for diverting exhausted gas.
  • 100% factory tested for leakage, crack, and reseal.
  • Cleaned and packaged for oxygen service.
Technical Data
  • Nominal Set Pressure Range: 10 – 750 Psig (0.7 to 51.7 Bar).
  • Factory Set Tolerance: ±3% for pressures ≥ 72.5 PSI, ±2.175 PSI for pressures < 72.5 PSI.
  • Zero leakage up to 95% of set pressure.
  • Full rated flow at 110% of set pressure, unaffected by up to 10% back pressure.
  • Reseat at 90% of set pressure, 85% for PCTFE seals below 100 Psig.
  • Temperature Rating: -320º to 350º F (-196º C to 176º C).
  • Lubricant: Krytox®.
Materials of Construction
  • Body, Poppet, and other components: Brass, ASTM B16.
  • Spring: 302 (ASTM A313) or 17-4PH (ASTM A564).
  • Seal: PCTFE (ASTM D1430) or Fluorosilicone.
  • Identification Label: Mylar.
Flow Data
The discharge coefficient (Kd) varies with set pressure range, affecting flow capacity. Flow capacity can be calculated using Generant’s Online Flow Calculator.
Ordering Information
  • Nominal Set Pressure: 10-750 Psig (0.7 - 51.7 Bar).
  • Series options include CRV, CRVP2, CRVP3, CRVP4, CRVT, CRVD, CRVB4.
  • Inlet Pipe Size options: 1/4" Male (250B), 3/8" Male (375B), 1/2" Male (500B).
  • Seal Material options: Fluorosilicone for 10-49 Psig, PCTFE for above 50 Psig.
Proper Component Selection
System designers must consider total system design, including component function, material compatibility, pressure ratings, installation, environment, and maintenance for safe performance.
See more

Catalog excerpts

Cryogenic Relief Valve Brass (CRV)-1

CRYOGENIC RELIEF VALVE (BRASS) 1/4", 3/8” and 1/2" NPT 10 - 750 Psig (0.7 - 51.7 Bar) Description The Generant Series Brass CRV, Cryogenic Relief Valve is a spring reference over pressure protection device. The CRV incorporates Generant’s exclusive “Dirt Guard” feature which increases the valves ability to tolerate particulate contamination. This device is ideally suited for use as a “Blocked Line Safety” in cryogenic systems. The CRV is supplied cleaned and packaged for oxygen service. The valve can be ordered with set pressures ranging from 10 to 750 Psig (0.7 to 51.7 Bar) and come factory preset and permanently locked. Relief pressure can not be altered or adjusted in the field. Seat and poppet geometry combined with optimized spring ranges provide high flow rates with minimum pressure accumulation. Compact design and availability of a variety of inlet and outlet configurations reduces size and piping requirements. Relief pressure can be discharged to atmosphere or to a downstream connection. The CRV is supplied with Flourosilicone seals for set pressures from 10 – 49 Psig (0.7 – 3.4 Bar) and PCTFE seals for set pressures 50 – 750 Psig (3.5 – 51.7 Bar). Available CE marked in accordance to the requirements of the PED 97/23/EC Exclusive “Dirt Guard” poppet incorporates screen to extend valve life and ensure reliability High Flow Capacity and Excellent Reseal Performance Supplied Factory Preset and Permanently Locked for Tamper Proof Service Discharge to Atmosphere or a Wide Variety of Inline Piping Configurations Optional Deflector Cap available for diverting exhausted gas 100% Factory Tested for Leakage, Crack and Reseal Cleaned and Packaged for Oxygen Service Technical Data Nominal Set Pressure Range: 10 – 750 Psig (0.7 to 51.7 Bar) Factory Set Tolerance*: Set Pressure ≥ 72.5 PSI, ± 3% Set Pressure < 72.5 PSI, ± 2.175 PSI *tolerance specifications per EN ISO 4126-1. Zero Leakage to 95% of Set Pressure Full Rated Flow @ 110% of Set Pressure Unaffected by up to 10% Back Pressure Reseat: 90% of set pressure 85% for PCTFE seals set below 100 Psig (6.9 Bar) Temperature Rating: -320º to 350º F (-196º C to 176º C) based on seal material (see How To Order) Lubricant: Krytox® Materials of Construction Component Body, Poppet, Adjusting Spring Retainer, Pipe-Away Adapters, Deflector Cap, Tamper Proof Ring Material Brass, ASTM B16 PCTFE (ASTM D1430), or Fluorosilicone Seal Color Coded Identification Label

 Open the catalog to page 1
Cryogenic Relief Valve Brass (CRV)-2

CRYOGENIC RELIEF VALVE (BRASS) Flow Data Set Pressure Range (Psig) From Valve Orifice .250” (6.35mm) Diameter (same for 1/4", 3/8" and 1/2" NPT) *Flow Coefficient Kd is stated at 110% accumulation Relief Valve Flow Capacity can be calculated using Generant’s Online Flow Calculator at www.generant.com or contact Customer Service at 973-838-6500. CRV – 250B – K – 350 SERIES CRV -Cryogenic Relief Valve CRVP2 -Cryogenic Relief Valve with 1/4" Female Pipe-A-Way Adapter Installed CRVP3 -Cryogenic Relief Valve with 3/8" Female Pipe-A-Way Adapter Installed CRVP4 -Cryogenic Relief Valve with 1/2" Female...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.