CRYOGENIC/PRESSURE BUILD REGULATOR 3/8” and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) Description The Generant Series CR Cryogenic Regulator provides high flow during Cryogenic Vessel Pressure Build function and increased sensitivity to downstream pressure changes as a function of our pre-formed all metallic diaphragm and optimized spring design. The unique diaphragm is unlike anything on the market today and results in less decrease in Cryogenic vessel pressure and faster recovery during periods of higher demand, thus decreasing the potential for flooding the pressure build coil. The unit features a 304 SS Inlet Strainer/Filter to aid in reducing contaminant related failures. Optional Cleaned and Packaged for Oxygen Service Series CR Regulators utilize Monel Inlet Strainer/Filters. All Series CR Cryogenic Regulators are 100% Factory Tested and are supplied factory pre-set. Features • Designed for High Flow Liquid Service • Can be installed Upstream or Downstream of the Vaporizer • Unique Pre-Formed Multiple Stacked Phosphorous Bronze Diaphragms • Can be Supplied Factory Preset • Hex Head Adjustment Screw with Locknut • 304 SS Inlet Strainer/Filter • Optional Cleaned and Packaged for Oxygen Service (includes Monel Inlet Strainer/Filter) Materials of Construction • Forged Brass Body and Chamber, ASTM 377 • Brass Bar Stock Components, ASTM B16 • Phosphorous Bronze Diaphragms, ASTM B103 • PTFE Valve, Diaphragm and Bottom Plug Seal, ASTM D1710 • PCTFE Valve Stem Bearing, ASTM D1430 • 17-7PH Stainless Steel Adjustment and Valve Spring, ASTM A313 • Stainless Steel Adjustment Screw and Locknut, ASTM A276 • 304 SS Inlet Strainer/Filter (Monel Inlet Strainer/Filter when specified for Oxygen Service)

Open the catalog to page 1
Cryogenic / Pressure Build Regulator (CR) - 2

CRYOGENIC/PRESSURE BUILD REGULATOR Technical Data Flow Capacity Maximum Inlet Pressure: 400 Psi (28 Bar) Outlet Pressure Range: 0 to 235 Psi (0 to 16 Bar) Temperature Range: -320° to 225° F (78° to 380° K) Fail Open CV: 3/8” NPT Ports – 2.4 1/2” NPT and BSPT Ports – 2.9 Flow Capacity is system dependent. For accurate flow capacity data, consult Generant with your specific system characteristics for more information. How To Order Repair Kits 2CR – 375 – C - X CLEANING OPTION X- Cleaned and Packaged for Oxygen Service (includes Monel Inlet Strainer/Filter) SERIES 2CR – 2 Port Cryogenic/...

Open the catalog to page 2

All Generant catalogs and technical brochures