Specifications: Insertion Loss Return Loss Wavelength Dependent Loss Optical Power Sensitivity Max. Optical Input Power Optical Damage Power SOP Accuracy (At Calibration Wavelength) 300 mW min. 50 kHz with preamplifier board Analog bandwidth for optical head alone is 1.5 MHz 1% max. DOP Accuracy (At Calibration Wavelength) Measurement Bandwidth Storage Temperature Optical Module Dimension Fiber Type Electrical Interface 20 pin w/ preamplifier board -5 V ~ -10 V w/o preamplifier boards Electrical Power Supply Note: Values are referenced without connectors. 1. Contact General Photonics regarding other wavelengths. APPLICATION GUIDE Preamplifier Board Dimensions . High speed and low loss . Compact size . No moving parts Wavelength Range Operating Temperature POLARIZATION MANAGEMENT MODULES General Photonics’ in-line polarimeter is specially designed for low cost, high-speed polarization characterization without interrupting data traffic. It outputs four voltage signals for calculating both the degree of polarization (DOP) and the state of polarization (SOP) of the light passing through the device in microseconds. PolaDetectTM is ideal for integration into polarization monitoring and polarization stabilization modules, or in polarization characterization instruments. It comes with a preamplification board to provide analog signals for SOP/DOP calculation, feedback control, and computer interface. A calibration matrix is provided with every device for the calculation. Devices without preamplification board and calibration matrix are also available for OEM purposes. The output fiber can either be single mode or PM fiber. TIMING/DELAY MANAGEMENT MODULES High Speed In-line Polarimeter – PolaDetect™ SPECIAL POLARIZATION COMPONENTS General Photonics Corporation 909.590.5473 http://www.generalphotonics.com -45-
Open the catalog to page 1High Speed In-line Polarimeter – PolaDetect™ Applications: Polarization stabilization Polarization division multiplexing POLARIZATION TIMING/DELAY SPECIAL POLARIZATION COMPONENTS MANAGEMENT MODULES MANAGEMENT MODULES APPLICATION GUIDE Sample/tissue birefrigence analysis (Con-focal arrangement) Remote sensing (remote stress analysis) -46- General Photonics Corporation 909.590.5473 http://www.generalphotonics.com
Open the catalog to page 2High Speed In-line Polarimeter – PolaDetect™ Figure 1. SOP and DOP accuracy compared with Agilent 8509C polarization analyzer. Dimensions (inches) : 15 = 1550 nm SS = SM in / SM out 01 = w/o preamplifier Connector type: 02 = with preamplifier FC/PC, FC/APC SC/PC, SC/APC or NC = no connectors Others specify General Photonics Corporation 909.590.5473 http://www.generalphotonics.com -47- APPLICATION GUIDE Figure 4. Partial polarized light DOP measurement compared with Agilent 8509C Figure 3. Polarization dependent loss (PDL) vs. wavelength SPECIAL POLARIZATION COMPONENTS Figure 2. Insertion loss...
Open the catalog to page 31 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page