Combustible Gas GENERAL MONITORS Protection for life. • Compatible with Automatic Remote Gas Calibrator • Fully automatic calibration • Event logging • Stores fault, gas check, calibration, and alarm event history • HART and Modbus communication • Provides complete status and control capability in the control room • Industry standard output for remote alarm and fault indication • Warning, Alarm & Fault Relays • Provides local alarm capability • Calibration, Calibration Check, Setup Modes • Simplifies operation and maintenance • Remaining sensor life indication Intelligent Sensor for Combustible Gas Detection • Reduces downtime by providing an estimate of remaining sensor life Description The Model S4000CH Intelligent Sensor is a microprocessor-based transmitter designed for use with General Monitorsʼ catalytic bead sensors. The unit features one person calibration and can virtually selfcalibrate by simply activating a magnetic switch and applying gas. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. All of the Model S4000CH electronics are contained within an explosion-proof housing so that sensor information can be processed at the sensor site. The detector uses a 4-20 mA analog output signal that is proportional to 0 to 100% LEL gas concentration at the sensor. In addition, the Model S4000CH includes warning, alarm, and fault relay contacts that can be used to indicate an alarm or fault condition and dual redundant Modbus or HART communication. Configurations with relays, Modbus, and HART are available to meet many needs. The Model S4000CH also includes a three-digit LED display. This local display continuously indicates gas concentrations during normal operation or in the Gas Check Mode, calibration prompts during Calibration Mode, display codes during the Setup Mode, and eight fault codes. The Model S4000CH has four different operating modes. First, a normal operating mode in which alarms are active and the display and 4-20 mA readings are proportional to the gas concentration at the sensor. Second, a gas check mode that allows the user to apply a gas and check the sensor response while alarm outputs are inhibited. Third, a calibration mode in which gas is applied to the sensor to calibrate the unit. Finally, a setup mode which allows the user to review or change setup options such as relay settings, calibration level, and Modbus parameters. Selecting Setup Mode on the Model S4000CH is accomplished by using the magnetic switch or HART or Modbus command. Options include: • Calibration level • Energized/de-energized relays • Latching/non-latching relays • Alarm set points for relays • Baud rate, data format, and address for each Modbus channel
Open the catalog to page 1MODEL S4000CH System Specifications Electrical Specifications Sensor Type: Continuous diffusion, low temperature catalytic bead Input Power: Sensor Life: Relay Ratings: (Optional) 8A @ 250 VAC / 8A @ 30 VDC res. max. (3x) SPDT - Warning, Alarm & Fault Analog Signal: Zero Drift: Less than 5% of full scale per year 0-20 mA (650 Ohms max. load) Malfunction 0 mA† Gas Check/Calibrate 1.5 mA‡ Setup mode 1.5 mA‡ Zero reading 4 mA ± .05 mA 0-100% LEL 4-20 mA Over-range 20-22 mA Response Time: T50 <10 s T90 <30 s with 100% LEL methane applied Measuring Ranges: 0-100% LEL Modes: RFI/EMI Protection:...
Open the catalog to page 2All General Monitors catalogs and technical brochures
-
Calibration Adapter
2 Pages
-
FL3100 Flame Detector series
4 Pages
-
MODELS FL3110/FL3111
2 Pages
-
MODEL FL802
2 Pages
-
TA402A
2 Pages
-
Product Guide
16 Pages
-
S4100T H2S Gas Detector
2 Pages
-
S4000TH H2S Gas Detector
2 Pages
-
IR400 Point IR Gas Detector
2 Pages