Catalog excerpts
Toxic Gas GENERAL MONITORS Protection for life. Infrared Carbon Dioxide Point Detector • True fail-to-safe operation • True gas detection performance • Event logging • Stores fault, gas check, calibration and alarm event history • No routine calibration required • Multiple communication outputs • Heated optics • Dirty optics indication • Wireless capability The Model IR700 infrared (IR) point detector is a microprocessor-based carbon dioxide gas detector that continuously monitors CO2 in ppm levels. The IR700 detection principle is based on measuring the absorption of infrared radiation passing through a volume of gas using a dual beam, single detector method. The IR detector measures the intensity of two specific wavelengths, one at an absorption wavelength and another outside of the absorption wavelength. The gas concentration is determined by a comparison of these two values. All of the IR700’s electronics are contained within an explosion-proof housing allowing detector information to be processed at the point of detection. The IR700 provides 4-20 mA signal proportional to 0-100% full scale. In addition, the IR700 is equipped with Modbus or HART. Configurations with relays, Modbus, and HART are available. The IR700 is calibrated at the factory and needs no routine field calibration. It requires only a periodic cleaning of the windows and re-zeroing to ensure dependable performance. • Provides complete status and control capability in the control room • Eliminates condensation • Discriminates between true fault and cleaning requirements • Compatible with ELPRO Technologies wireless devices The IR700 IR point detector is available in either an aluminum or stainless steel housing and is designed for use in Class I, Div. 1, Groups B, C & D and Zone 1 areas for North America and Zones 1 and 21 internationally. The housing is IP66 / Type 4X rated. Applications • Carbon Capture and Storage • Chemical Plants • Food & Beverage Bottling Plants • Coal Gasification • Wastewater Treatment Facilities
Open the catalog to page 1MODEL IR700 System Specifications Electrical Specifications Measuring Range: Analog Signal: Detector Type: Infrared absorption type 0 to 5000 ppm Consult factory for other ranges ± 5% full scale ≤ 2500 ppm ± 10% full scale > 2500 ppm Input Power: Detector Life: Response Time: Greater than 5 years Self test, normal operation, calibration (zero only or complete calibration) IR4000S CO2 monitor, junction box, duct mount junction box, calibration cup, flow block, splash guard, rain guard, portable purge calibrator Class I, Divisions 1 & 2, Groups B, C & D (Ta = -40°C to +75°C) Type 4X Ex d,...
Open the catalog to page 2All General Monitors catalogs and technical brochures
-
Calibration Adapter
2 Pages
-
FL3100 Flame Detector series
4 Pages
-
MODELS FL3110/FL3111
2 Pages
-
MODEL FL802
2 Pages
-
TA402A
2 Pages
-
Product Guide
16 Pages
-
S4100T H2S Gas Detector
2 Pages
-
S4000TH H2S Gas Detector
2 Pages
-
IR400 Point IR Gas Detector
2 Pages