1. Catalogs
  2. General Monitors
  3. IR5500 Open Path IR Gas Detector

IR5500 Open Path IR Gas Detector

IR5500 Open Path IR Gas Detector

IR5500 Open Path IR Gas Detector

Product catalog summary
Overview: The Model IR5500 is an open path infrared (IR) gas detector designed for continuous monitoring of methane and propane gas concentrations. It features dual detection ranges, a single detection beam, and multiple communication outputs, making it suitable for harsh environments.
Features and Benefits:
  • Dual detection ranges for both small (ppm•meter) and large (LEL•meter) gas leaks.
  • Continuous self-check and automatic gain control improve accuracy and reduce drift.
  • Multiple communication outputs including HART, Modbus, and AMS support.
  • Fail-safe operation and ease of use reduce operational costs.
  • Compensates for environmental factors like dirty optics, rain, and fog.
Description: The IR5500 system consists of an IR source and receiver that monitor methane and propane gas concentrations. It provides two 4 to 20 mA analog signals proportional to the detection ranges, a digital display, and relay contacts. The device is factory-calibrated and requires minimal maintenance.
Applications: Suitable for use in compressor stations, drilling platforms, fuel loading facilities, gas turbines, LNG/LPG processing, petrochemical tanks, tank farms, and wastewater treatment facilities.
System Specifications:
  • Sensor Type: Infrared Absorption
  • Detection Ranges: Methane (0 to 5000 ppm•meter, 0 to 5 LEL•meter), Propane (0 to 2000 ppm•meter, 0 to 1 LEL•meter)
  • Response Time: T90 < 3 seconds
  • Repeatability and Linearity: ≤ ±5%
  • Classification: Various hazardous location certifications including Class I, Div 1 & 2, and others.
  • Operating Temperature: -67°F to +149°F (-55°C to +65°C)
  • Input Power: 20 to 36 VDC
Mechanical and Environmental Specifications:
  • Housing: 316 stainless steel
  • Weight: Source 12.20 lb, Receiver 12.34 lb
  • Operating Humidity: 0-95% RH, non-condensing
Electrical Specifications:
  • Dual Analog Signals: 0-5000 ppm•meter, 0-5 LEL•meter
  • Relay Ratings: 8 A @ 250 VAC/8 A @ 30 VDC
  • RS-485 Output: Modbus RTU
  • HART: HART 6, Device Description available
Contact Information: General Monitors has offices worldwide including in the USA, Ireland, Singapore, UAE, UK, and China. For more information, visit their website at www.generalmonitors.com.
See more

Catalog excerpts

IR5500 Open Path IR Gas Detector-1

MODEL IR5500 Open Path Gas Detector Features • Dual detection ranges • Sensitive to both small (ppm•meter) and large (LEL•meter) gas leaks • Performance approved • Ideal for use in harsh environments • Single detection beam • Improves accuracy and reduces drift • Continuous self-check • Fail to safe operation • Multiple communication outputs (HART, Modbus, AMS Support) • Provides complete status and control capability in the control room • Unitized display • Ease of operation, reduced cost • Automatic gain control • Compensates for dirty optics, rain, and fog The Model IR5500 is an open path IR gas detector that provides continuous monitoring of methane and propane gas concentrations. The system consists of an IR source and receiver which continuously monitors for methane in both the 0 to 5000 ppm• meter and 0 to 5 LEL• meter range. A 0 to 2000 ppm• meter and 0 to 1 LEL• meter range is also available for monitoring propane. The IR5500 provides two 4 to 20 mA analog signals proportional to each of the above ranges, in addition to a digital display and relay contacts. • Compressor Stations The IR5500 is easily aligned using the digital display and adjustable mounting arms, therefore it does not require any bulky setup equipment (e.g. digital volt meters, handheld alignment aids). The IR5500ʼs sensitivity can be checked by placing a test gas film in front of the receiver. The IR5500 is calibrated at the factory and needs no further calibration. It also requires little maintenance save for a periodic visual inspection, test gas film check, and cleaning of the windows to assure dependable performance. Sensor data and status information from the IR5500 can be transmitted up to 9,000 feet to any industrial analog to digital (A/D) converter for use in multipoint computer-based monitoring. • Drilling and Production Platforms • Fence Line Monitoring • Fuel Loading Facilities • Gas Turbines • LNG/LPG Processing and Storage Facilities • Petrochemical Tanks • Tank Farms • Wastewater Treatment

 Open the catalog to page 1
IR5500 Open Path IR Gas Detector-2

MODEL IR5500 System Specifications Electrical Specifications Sensor Type: Input Power: Infrared Absorption 20 to 36 VDC range 24 VDC @ 12 W (max.) – source 24 VDC @ 10 W (max.) – receiver (w/relays) Consult factory for lower power consumption options for other configurations Dual Ranges Methane: 0 to 5000 ppm• meter 0 to 5 LEL• meter Propane: 0 to 2000 ppm• meter 0 to 1 LEL• meter Consult factory for other hydrocarbon gases available. Path Lengths: LEL• m: ppm• m: Dual Analog Signals: 5-30 m, 20-100 m, 50-150 m 5-30 m, 20-100 m, 80-150 m Response Time: ≤ ±5% of full scale for each scale or ±10%...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.