Features • All wetted parts made of PFA or PTFE • High flow rate with low-stress media channelling • Optional flow direction • Ideally suited for corrosive media • Metal-free design • Optional version with ECTFE union nut • Also available as T valve • Clean room production, fulfils SEMI F57 The ultra pure 2/2-way diaphragm valve GEMU C67 HPW CleanStar is manually operated. All media wetted parts are produced from PFA or PTFE (HPW version). For the HPS version, there is a choice of valve bodies made of PP-R, natural or PVDF. A seal adjuster (not with AG 4) and an optical position indicator are integrated as standard. This High Purity version of the CleanStar series complies with the strictest purity standards and boasts high chemical resistance. It can also be used with high media temperatures. As such, it is often used at the supply and distribution level in semiconductor factories. • Body configurations: 2/2-way bodies l T body l V valve body • Connection types: Flare l Flare SpaceSaver l Nexus Connect® l Nexus Connect® SpaceSaver l PrimeLock® l PrimeLock® SpaceSaver l Spigot l Super 300 Type Pillar® SpaceSaver l Union end l Welded-on Nexus Connect® • Body materials: PFA l PP-R, natural l PVDF • Diaphragm materials: PTFE/EPDM • Conformities: EAC l FDA l TA Luft (German Clean Air Act) Technical data depends on the respective configuration
Open the catalog to page 1CleanStar product line CleanStar product line
Open the catalog to page 4Product description
Open the catalog to page 5Designs Body configurations Body configuration T valve body (code T) The T body has 3 connections. The opposing connections (X and Z) are classed as main pipe, as media flows between them at all times, regardless of the position (open/closed) of the actuator. The branch (Y) is located at a 90° angle to the main pipe. The flow across this connection can be influenced via the actuator. The 2/2-way body is the most commonly used body configuration. Thanks to the seal created by the weir-style body, the flow direction is freely selectable. Various pipe and tube connections can be connected to the...
Open the catalog to page 6Designs Special versions Description High Flow (code F) In actuator sizes 2 and 3, the 2/2-way body is also available in a so-called High Flow design. This body version has a flow-optimized weir geometry. This reduces the pressure loss and thereby facilitates a higher flow. High Flow valve bodies are often used when higher volume flows are required. The upper image shows a cross-section of a standard version without High Flow. The lower image shows a cross-section of a High Flow design (code F). ECTFE union nut (code E) The central union nut, which connects the actuator to the body via a thread,...
Open the catalog to page 7Features • All wetted parts made of PFA or PTFE • High flow rate with low-stress media channelling • Optional flow direction • Ideally suited for corrosive media • Metal-free design • Optional version with ECTFE union nut • Also available as T valve • Clean room production, fulfils SEMI F57 The ultra pure 2/2-way diaphragm valve GEMU C67 HPW CleanStar is manually operated. All media wetted parts are produced from PFA or PTFE (HPW version). For the HPS version, there is a choice of valve bodies made of PP-R, natural or PVDF. A seal adjuster (not with AG 4) and an optical position indicator are...
Open the catalog to page 8Code 30: Spigot - inch, for welding or solvent cementing, depending on the body material Code 73: Flare connection with CPFA union nut Code 75: Flare connection with PVDF union nut Code 77: Flare connection with PFA union nut Code NX: Nexus Connect connection with PFA union nut Code PL: PrimeLock connection Code T3: Tube spigot
Open the catalog to page 9Connection type Flare (code 73, 75, 77)
Open the catalog to page 10Connection type Flare in pos. X, butt weld spigot in pos. Z (code K)
Open the catalog to page 11Body configuration - T body (code T) X-->Z: Main pipe (Flow even when valve is closed) X-->Y: Branch (Flow only when valve is open) Flare connection type (code 73, 75, 77) Actuator size Connection Connection (code) size X, Z size Y (code) (code) 1, 1E Space saver position Butt weld spigot connection type (code 30) Actuator size Connection size X, Connection size Y (code) Z (code) (code) 1, 1E 2, 2E Butt weld spigot, pos. X, Y, Z Butt weld spigot, pos. X, Z Space saver, pos. Y
Open the catalog to page 13Order codes
Open the catalog to page 14Order data - body configuration - 2/2-way body (code D)
Open the catalog to page 15Order data - body configuration - T body (code T) The order data provide an overview of standard configurations. Please check the availability before ordering. Other configurations available on request.
Open the catalog to page 16Order data - body configuration - T body (code T)
Open the catalog to page 17Technical data C67 PFA Medium Working medium: Corrosive, inert, gaseous and liquid media – in particular high-purity media – which have no negative impact on the physical and chemical properties of the body and diaphragm material. Temperature Media temperature: PFA valve body material (code 30): -10 — 150 °C Observe pressure/temperature diagram Ambient temperature: Storage temperature: Pressure Operating pressure:
Open the catalog to page 18Valve body material: PFA (code 30), actuator sizes 1, 2 and 3 Valve body material: PFA (code 30), actuator sizes 4, 4E * Note: The temperature/pressure diagram is only an aid. The data refers to water as a working medium. A change of operating conditions or other media may result in deviations. In case of doubt, it is advisable to test the behaviour of the material under the definitive operating conditions in a test installation. Temperatures below 0 °C can have a negative influence on the actuation speed. The pressure-bearing valve bodies are designed to maintain their functionality unchanged...
Open the catalog to page 19Kv values: Body configuration - 2/2-way body (code D)
Open the catalog to page 20Body configuration - T body (code T) At branch Y Kv values in l/min The service life of the valve may be affected if exposed to a greater vacuum or when valves are installed on the pump suction side.
Open the catalog to page 21Product conformities Machinery Directive: 2006/42/EC The product is certified according to EAC. Flow direction: Optional
Open the catalog to page 2214 Pages
20 Pages
14 Pages