Features • High mechanical stability • High flow rate due to straight through flow • Can be retrofitted with a pneumatic actuator The GEMU 655 2/2-way diaphragm valve has a metal handwheel and is manually operated. The valve body has a full bore design. • Body configurations: 2/2-way body • Connection types: Flange • Connection standards: ANSI l EN l ISO • Body materials: EN-GJL-250, cast iron material l EN-GJS-400-18-LT, SG iron material l EN-GJS-500-7, ductile iron material • Body lining: Butyl l Hard rubber l Soft rubber • Diaphragm materials: CR l EPDM l IIR l NBR l NR Technical data depends on the respective configuration further information webcode: GW-655
Open the catalog to page 1Product description
Open the catalog to page 2MG = diaphragm size, X = standard * on request Code 4: Flange EN 1092, PN 10, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 Code 8: Flange EN 1092, PN 16, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 Code 52: Flange EN 1092, PN 10, form A, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 Code 53: Flange EN 1092, PN 16, form A, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 Valve body material Code 13: EN-GJL-250 (GG 25), hard rubber lined Code 16: EN-GJS-500-7 (GGG-50), hard rubber lined Code...
Open the catalog to page 3MG = diaphragm size, X = standard * on request Code 39: Flange ANSI Class 125/150 RF, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 Code 58: Flange ANSI Class 125/150 FF, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 2) Valve body material Code 13: EN-GJL-250 (GG 25), hard rubber lined Code 16: EN-GJS-500-7 (GGG-50), hard rubber lined Code 52: EN-GJL-250 (GG 25), soft rubber lined Code 58: EN-GJL-250 (gG 25), butyl lined Code 82: EN-GJS-400-18-LT (GGG 40.3), soft rubber lined Code 83: EN-GJS-400-18-LT (gGG 40.3), hard rubber lined Code 88: EN-GJS-400-18-LT...
Open the catalog to page 4Order data The order data provide an overview of standard configurations. Please check the availability before ordering. Other configurations available on request.
Open the catalog to page 5Order data
Open the catalog to page 6Technical data Media temperature: Ambient temperature: Storage temperature: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and chemical properties of the body and diaphragm material. All pressures are gauge pressures. Operating pressure values were determined with static operating pressure applied on one side of a closed valve. Sealing at the valve seat and atmospheric sealing is ensured for the given values. Information on operating pressures applied on both sides and for high purity media on request. Valve not suitable for vacuum applications
Open the catalog to page 7Technical data MG = diaphragm size, Kv values in m3/h Kv values determined in accordance with EN 60534, inlet pressure 5 bar, Ap 1 bar, valve body material cast iron EN-GJL-250 with connection flange EN 1092 length EN 558 series 7 and soft elastomer diaphragm. The Kv values for other product configurations (e.g. other diaphragm or body materials) may differ. In general, all diaphragms are subject to the influences of pressure, temperature, the process and their tightening torques. Therefore the Kv values may exceed the tolerance limits of the standard. The Kv value curve (Kv value dependent on...
Open the catalog to page 8Technical data MG = diaphragm size Weights in kg
Open the catalog to page 9* CT = A + H1 (see body dimensions) Dimensions in mm
Open the catalog to page 10Dimensions in mm MG = diaphragm size n = number of bolts Code 4: Flange EN 1092, PN 10, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 2) Valve body material Code 82: EN-GJS-400-18-LT (GGG 40.3), soft rubber lined Code 83: EN-GJS-400-18-LT (gGG 40.3), hard rubber lined Code 88: EN-GJS-400-18-LT (gGG 40.3), butyl lined
Open the catalog to page 11Dimensions in mm MG = diaphragm size n = number of bolts Code 8: Flange EN 1092, PN 16, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 2) Valve body material Code 82: EN-GJS-400-18-LT (GGG 40.3), soft rubber lined Code 83: EN-GJS-400-18-LT (gGG 40.3), hard rubber lined Code 88: EN-GJS-400-18-LT (gGG 40.3), butyl lined
Open the catalog to page 12Dimensions in mm MG = diaphragm size n = number of bolts Code 52: Flange EN 1092, PN 10, form A, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 2) Valve body material Code 13: EN-GJL-250 (GG 25), hard rubber lined Code 16: EN-GJS-500-7 (GGG-50), hard rubber lined Code 52: EN-GJL-250 (GG 25), soft rubber lined Code 58: EN-GJL-250 (gG 25), butyl lined Code 92: EN-GJS-500-7 (GGG 50), soft rubber lined Code 98: EN-GJS-500-7 (gGG 50), butyl lined
Open the catalog to page 13MG = diaphragm size Dimensions in mm n = number of bolts Code 53: Flange EN 1092, PN 16, form A, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 2) Valve body material Code 16: EN-GJS-500-7 (GGG-50), hard rubber lined Code 92: EN-GJS-500-7 (gGG 5o), soft rubber lined Code 98: EN-GJS-500-7 (gGG 5o), butyl lined
Open the catalog to page 14Dimensions in mm MG = diaphragm size n = number of bolts Code 39: Flange ANSI Class 125/150 RF, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1 2) Valve body material Code 82: EN-GJS-400-18-LT (GGG 40.3), soft rubber lined Code 83: EN-GJS-400-18-LT (gGG 40.3), hard rubber lined Code 88: EN-GJS-400-18-LT (gGG 40.3), butyl lined 3) not according to ASME standard
Open the catalog to page 15Dimensions in mm MG = diaphragm size n = number of bolts Code 58: Flange ANSI Class 125/150 FF, face-to-face dimension FTF EN 558 series 7, ISO 5752, basic series 7 2) Valve body material Code 13: EN-GJL-250 (GG 25), hard rubber lined Code 16: EN-GJS-500-7 (GGG-50), hard rubber lined Code 52: EN-GJL-250 (GG 25), soft rubber lined Code 58: EN-GJL-250 (gG 25), butyl lined Code 92: EN-GJS-500-7 (GGG 50), soft rubber lined Code 98: EN-GJS-500-7 (gGG 50), butyl lined
Open the catalog to page 16Dimensions in mm, MG = diaphragm size n = number of bolts The thread of the diaphragm pin "W" corresponds to Whitworth standard.
Open the catalog to page 17GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8, 74653 Ingelfingen-Criesbach, Germany Phone +49 (0) 7940 1230 · [email protected] www.gemu-group.c
Open the catalog to page 1814 Pages
20 Pages
14 Pages