1. Catalogs
  2. Gema Switzerland
  3. MagicControl CM10

MagicControl CM10

MagicControl CM10
1 / 61 PagesView full catalog

MagicControl CM10

Product catalog summary
General Safety Regulations
This section emphasizes the importance of understanding safety regulations for the Magic Control CM-10 Plant control. Key safety symbols warn about live electricity, moving parts, and improper use. It is crucial for users and third parties to adhere to these regulations to ensure safety.
Conformity of Use
The Magic Control CM-10 is specifically designed for powder coating applications. It must be used according to the manufacturer's guidelines, and any unauthorized modifications or improper use will void the manufacturer's liability. Compliance with operating, service, and maintenance instructions is essential.
Technical Safety Regulations
This section covers safety regulations for stationary electrostatic powder spraying equipment. It stresses the importance of using the equipment as specified to avoid dangers. Regular servicing and adherence to safety regulations like BGI 764 and VDE are mandatory.
Product Specific Security Measures
Only original Gema spare parts should be used to maintain explosion protection. Familiarity with the equipment and its functions before operation is crucial for safety.
Operating Instructions
The manual provides detailed instructions on starting up and operating the Magic Control CM-10, including manual and automatic operation modes, parameterization, and error diagnostics. It also includes a spare parts list and ordering information.
Conclusion
The document emphasizes the importance of safety and proper use of the Magic Control CM-10 Plant control, providing detailed instructions and regulations to ensure safe and efficient operation.
Overview
This document provides comprehensive operating instructions and safety regulations for the Magic Control CM-10 Plant control, designed for electrostatic powder coating with organic powders. It highlights the importance of proper training, adherence to safety protocols, and the use of authorized personnel for operation and maintenance.
Safety Regulations
The document outlines general safety regulations, including the necessity for trained personnel, prohibition of unauthorized modifications, and requirement for regular equipment checks. It highlights the importance of grounding, proper ventilation, and protective clothing to prevent hazards such as electric shocks, static charges, and dust explosions.
Operating Instructions
Detailed instructions are provided for the setup, operation, and maintenance of the powder spraying equipment. The document stresses the importance of following shutdown procedures and using original replacement parts to maintain safety and equipment integrity.
Technical Specifications
The Magic Control CM-10 is equipped with a RISC/1000 MIPS processor, 64 MB memory, and a TFT color LCD display. It operates on a nominal voltage of 24 VDC and includes features such as reverse voltage protection and infrared touch operation.
Environmental Conditions
The equipment is designed to operate within a temperature range of 0-50°C and 10-85% relative humidity. It is tested for vibration, shock, and drop resistance according to IEC standards.
Regulatory Compliance
The document lists relevant guidelines and standards, including European and German regulations, to ensure compliance with safety and operational requirements in potentially explosive atmospheres.
Start-up and Configuration
The equipment is pre-configured and tested to facilitate a faster start-up process. The document provides guidance on parameter adjustments and offers laboratory report data for initial settings.
Key Symbols and Colors
The document uses specific symbols and colors to indicate the status of keys and components. Violet indicates components not accessible by CAN bus, while yellow indicates accessibility. Green signifies active operations, and red indicates errors.
Startup Procedures
The startup process involves switching on the main switch and control voltage, logging in to activate keys, and selecting operating modes. The system can operate in manual, automatic, or cleaning modes, each with specific functions and controls.
Operating Modes
The system supports various modes:
  • Manual Mode: Allows for manual control of axes and guns, with options to edit values and start/stop operations.
  • Automatic Mode: Automatically starts guns and axes based on light grid information, with options for object changes and powder output correction.
  • Cleaning Mode: Involves specific steps for external and internal gun cleaning, including door operations and axis movements.
Parameterization
This section covers setting general parameters, station parameters, and calibrating the CAN bus sensor. It includes details on booth parameters, light grid evaluations, and object data management.
Error Display and Diagnostics
The system provides a comprehensive error display and diagnostics section, including error history, active CAN bus devices, and digital input/output management. It also tracks operating hours for various components.
User Levels and Access
The document outlines the login process for accessing different user levels, requiring a username and password for system access.
User Levels and Access
  • User Level 0: Full access without limitations, reserved for specialized Gema staff. Automatic logout after 3 minutes.
  • User Level 1: No configuration allowed, but plant parameters and object-related data can be modified. Automatic logout after 30 minutes.
  • User Level 2: No configuration or parameterization allowed. Object-related data can be modified. No automatic logout.
  • User Level 3: Limited to activating existing object data, modifying daily corrections, and deselecting guns. No automatic logout.
  • No User Level: Logged out status.
Plant Configuration
  • Adjust time and select system language (German/English).
  • Define, delete, and manage users, including password changes.
  • Adjust brightness and access system information.
  • Backup configurations under '99 Backup'.
  • Define station, axes, guns, and set object recognition type.
Spare Parts Ordering
  • Provide type, serial number, order number, quantity, and description when ordering.
  • Specify length for cable or hose material.
  • Use only original Gema spare parts to maintain explosion protection and warranty.
See more

Catalog excerpts

MagicControl CM10-1

Operating instructions and spare parts list Magic Control CM-10 Plant control Translation of the original operating instructions

 Open the catalog to page 1
MagicControl CM10-2

Documentation Magic Control CM-10 Plant control © Copyright 2005 Gema Switzerland GmbH All rights reserved. This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH. OptiTronic, OptiGun, EasyTronic, EasySelect, OptiFlow and SuperCorona are registered trademarks of Gema Switzerland GmbH. OptiMatic, OptiMove, OptiMaster,...

 Open the catalog to page 2
MagicControl CM10-3

Table of contents General safety regulations About this manual Function description Technical Data Magic Control CM-10 Plant control

 Open the catalog to page 3
MagicControl CM10-4

Operating modes Object data administration Error display / diagnostics User levels and access Plant configuration Spare parts list Magic Control CM-10 Plant control

 Open the catalog to page 4
MagicControl CM10-5

General safety regulations This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the Magic Control CM-10 Plant control. These safety regulations must be read and understood before the Magic Control CM-10 Plant control is used. Safety symbols (pictograms) The following warnings with their meanings can be found in the Gema operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions. DANGER! Danger due to live electricity or moving parts. Possible consequences: Death...

 Open the catalog to page 5
MagicControl CM10-6

use. The Magic Control CM-10 Plant control should only be used, maintained and started up by trained personnel, who are informed about and are familiar with the possible hazards involved. 4. Start-up (i.e. the execution of a particular operation) is forbidden until it has been established that the Magic Control CM-10 Plant control has been set up and wired according to the guidelines for machinery (2006/42 EG). EN 60204-1 (machine safety) must also be observed. 5. Unauthorized modifications to Magic Control CM-10 Plant control exempt the manufacturer from any liability from resulting damage....

 Open the catalog to page 6
MagicControl CM10-7

operation. Safety precautions specified by local legislation must be observed! 8. Only original Gema spare parts should be used, because the explosion protection will also be preserved that way. Damage caused by other parts is not covered by guarantee. 9. If Gema powder spraying equipment is used in conjunction with machinery from other manufacturers then their safety regulations must also be taken into account. 10. Before starting work familiarize yourself with all installations and operating elements, as well as with their functions! Familiarization during operation is too late! 11. Caution...

 Open the catalog to page 7
MagicControl CM10-8

3. For dangerous materials, the employer has to provide an operating instructions manual, which specifies the dangers arising for humans and environment by handling dangerous materials, as well as the necessary preventive measures and behavior rules. The operating instructions manual has to be written in an understandable form and in the language of the persons employed, and has to be kept in a suitable place in the working area. 4. The operator is under obligation to check the powder spraying equipment at least once every shift for signs of external damage, defects or changes (including the...

 Open the catalog to page 8
MagicControl CM10-9

pension gear must ensure that the machinery remains earthed. If the earthing of the machinery includes the suspension arrangements, then these must constantly be kept clean in order to guarantee the necessary conductivity. The appropriate measuring devices must be kept ready in the workplace in order to check the earthing. Compressed air When there are longer pauses or stand-still times between working, the powder spraying equipment should be drained of compressed air. There is a danger of injury, when pneumatic hoses are damaged, and from the uncontrolled release and improper use of compressed...

 Open the catalog to page 9
MagicControl CM10-10

tion with the coating booth, the recovery unit and the conveyor chain and with the suspension arrangement of the objects. 7. The electricity and powder supply to the hand guns must be set up so that they are fully protected against heat and chemical damage. 8. The powder coating device may only be switched on once the booth has been started up. If the booth cuts out then the powder coating device must be switched off. 9. The earthing of all electricity conducting devices (e.g. hooks, conveyor chains) must be checked on a weekly basis. The earthing resistance should not exceed 1 MOhm. 10. The...

 Open the catalog to page 10
MagicControl CM10-11

GemaEN European standards RL94/9/EC VDE (Association of German Engineers) Regulations DIN VDE 0100 ‘Sources: 1 Carl Heymanns Verlag KG, Luxemburger Strasse 449, 5000 Koln 41, or from the appropriate employers association 2) Beuth Verlag GmbH, Burgrafenstrasse 4, 1000 Berlin 30 3) General secretariat, Rue Brederode 2, B-1000 Bruxelles, or the appropriate national committee 4) VDE Verlag GmbH, Bismarckstrasse 33, 1000 Berlin 12 Magic Control CM-10 Plant control General safety regulations • 9

 Open the catalog to page 11
MagicControl CM10-12

Product specific security measures - Before starting up the plant a check must be made to ensure that no foreign objects are in the booth or in the ducting (input and exhaust air) 10 • General safety regulations The installation work, to be done by the customer, must be carried out according to local regulations It must be observed, that all components are grounded according to the local regulations, before start-up Magic Control CM-10 Plant control

 Open the catalog to page 12
MagicControl CM10-13

Gema About this manual General information This operating manual contains all important information which you require for the working with the Magic Control CM-10 Plant control. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system. Information about the function mode of the individual system components - booth, gun control unit, manual gun or powder injector - you will find in the corresponding enclosed documentations. This document describes the operation of the Magic Control CM-10 Plant control starting...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.