Three-phase and AC motors

Three-phase and AC motors
1 / 63 PagesView full catalog

Three-phase and AC motors

Product catalog summary
Technical Document Summary
1. Specifications
This document provides comprehensive specifications for various types of AC motors, including both single-phase and three-phase asynchronous motors with 2-pole and 4-pole configurations. Designed primarily for a 230 V / 50 Hz AC system, with options for other voltages and frequencies, these motors feature key specifications such as nominal power, speed, torque, current, efficiency, and thermal limits. They are built for a service life of 20,000 hours under S1 duty, with insulation material class options of B and F, and protection systems ranging from IP 40 to IP 65.
2. Procedures and Options
The document details connection procedures, including cable connections and optional plug-in connectors. It also covers the requirements for running capacitors and thermal protection options. Customization options include thermal protection, special shafts, and custom designs, suitable for short-time duty with high performance.
3. Gear Unit Combinations
Recommended combinations of motors with gear units are outlined, including worm, spur, and planetary gears. Each gear type is specified with reduction ratios, resulting speeds, and torques. The document emphasizes the importance of matching motor power with gear output to avoid overloading, with additional reductions available upon request.
4. Motor Properties and Dynamics
Motors are equipped with features such as running capacitors and optional plug-in connectors. The document provides details on motor dynamics, including weight, moment of inertia, and coupling specifications. Maximum axial and radial forces are specified for each motor type.
5. Performance Characteristics
Performance metrics such as nominal efficiency, input power, and moment of inertia are provided. The motors are capable of handling specific axial and radial forces, with detailed data on locked rotor speeds and torques.
6. Recommendations and Additional Features
The document suggests additional gear unit combinations and reductions upon request, emphasizing that all torques are calculated with a duty factor of 1. It also notes that motor power may need to be limited to prevent exceeding maximum load at the gear output. Recommended accessories include rotary encoders and brakes, with dimensions and weight details provided for each motor type.
See more

Catalog excerpts

Three-phase and AC motors-2

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Cable connection, optional plug-in connectorService life:20,000 hours, S1 duty Insulation mat. class: B, optional F System of protection:IP 40, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special gears, special flanges, custom designed Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W1012Nominal speedn > nom rpm27002600Nominal torqueT > nom cNm3.55.0Starting...

 Open the catalog to page 2
Three-phase and AC motors-3

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 1 (Page Sc-05)(Data upon request)S 567(Page Sc-02)Z 67 (Page St-04) P50(Page P-02) Type Name > Nominal voltage / AC voltage230230 nMnM S 446Worm gear 1-stage rpmnMrpmNm i=2.2512000.111560.1i=55400.15200.2 Diagram upon request i=73860.23710.2 i=102700.22600.3 i=151800.31730.4 i=251080.41040.5 i=30900.4870.6 i=40680.4650.5 i=50540.6520.8 i=60450.5430.8 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary)...

 Open the catalog to page 3
Three-phase and AC motors-4

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Cable connection, optional plug-in connectorService life:20,000 hours, S1 duty Insulation mat.class:B, optional F System of protection:IP 40, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W35Nominal speedN > nom rpm12001200Nominal torqueT > nom cNm2,43.8Starting...

 Open the catalog to page 4
Three-phase and AC motors-5

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 1 (Page Sc-05)(Data upon request)S 567(Page Sc-02)Z 67 (Page St-04) P50(Page P-02) Type Name > Nominal voltage / AC voltage230230 nMnM S 446Worm gear 1-stage rpmNmrpmNm i=2.255330.15330.1i=52400.12400.1 Diagram upon request i=71710.11710.2 i=101200.21200.2 i=15800.2800.3 i=25480.3480.4 i=30400.3400.4 i=40300.2300.4 i=50240.4240.6 i=60200.4200.6 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary)...

 Open the catalog to page 5
Three-phase and AC motors-6

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W1926Nominal speedN > nom rpm25002650Nominal torqueT > nom...

 Open the catalog to page 6
Three-phase and AC motors-7

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 3 (Page Sc-06)(Data upon request)Z 89 (Page St-05)P60(Page P-03) Type Name > Nominal voltage / AC voltage230230 nMnM S 567Worm gear 1-stage rpmNmrpmNm i=3.66940.27360.2i=55000.25300.3 i=102500.42650.5 i=201250.81331.0 i=241040.81101.1 i=30830.9881.2 i=40631.1661.5 i=50501.3531.7 i=60421.7442.3 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary) Additional reductions upon request. nMnM Z 6 Spur gear...

 Open the catalog to page 7
Three-phase and AC motors-8

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W711Nominal speedN > nom rpm12501000Nominal torqueT > nom...

 Open the catalog to page 8
Three-phase and AC motors-9

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 3 (Page Sc-06)(Data upon request)Z 89 (Page St-05)P60(Page P-03) Type Name > Nominal voltage / AC voltage230230 nMnM S 567Worm gear 1-stage rpmNmrpmNm i=3.63470.12780.3i=52500.22000.3 i=101250.31000.6 i=20630.6501.1 i=24520.6421.2 i=30420.7331.4 i=40310.9251.7 i=50251.0201.9 i=60211.3172.5 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary) Additional reductions upon request. nMnM Z 6 Spur gear 1-3...

 Open the catalog to page 9
Three-phase and AC motors-10

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230230 Specification Nominal powerP > 2 W31.043.578.5Nominal speedN > nom rpm240027002800Nominal...

 Open the catalog to page 10
Three-phase and AC motors-11

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:M 189(Page St-09)(Data upon request)S 769(Page Sc-04)P80(Page P-04) Type Name > Nominal voltage / AC voltage230230230 nMnMnM GS 3Worm gear 1-stage rpmNmrpmNmrpmNm i=2.59600.310800.311200.55i=54800.55400.65601.05 i=73430.73860.84001.4 i=102400.92701.12801.8 i=151601.21801.51872.6 i=201201.41351.81403.1 i=30801.8902.2933.8 i=50482.2542.7564.7 i=70343.0393.7406.4 i=100243.5274.3287.6 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power...

 Open the catalog to page 11

All Gefeg-Neckar Antriebssysteme GmbH catalogs and technical brochures

  1. M 10

    1  Page

  2. PSA 52

    1  Page

  3. PM 30

    1  Page

  4. PSA 68

    1  Page

  5. G 6

    1  Page

  6. M 7

    1  Page

  7. S 769

    1  Page

  8. MQ 5

    1  Page

  9. DRIVE SYSTEMS

    12  Pages

  10. M 67

    1  Page

  11. M189

    1  Page

  12. Z5

    1  Page

  13. Z6

    1  Page

  14. Z8

    1  Page

  15. Z67

    1  Page

  16. Z89

    1  Page

  17. D5

    2  Pages

  18. D6

    2  Pages

  19. D8

    2  Pages

  20. D95

    2  Pages

  21. K8

    2  Pages

  22. K95

    2  Pages

  23. GS1

    1  Page

  24. GS3

    1  Page

  25. S345

    1  Page

  26. S567

    1  Page

  27. S668

    1  Page

  28. SC401

    1  Page

  29. SC401H

    1  Page

  30. Dg 71

    4  Pages

  31. U 63

    2  Pages

  32. KD 8

    4  Pages

  33. KD 6

    4  Pages

  34. D 8

    4  Pages

  35. D 5

    4  Pages

  36. Es 71

    4  Pages

  37. K 95

    4  Pages

  38. K 5

    4  Pages

  39. PSA 63

    1  Page

  40. PSA 45

    1  Page

  41. MSA 8

    1  Page

  42. MSA 5

    1  Page

  43. PC 63

    2  Pages

  44. MQ5

    2  Pages

  45. MQ8

    2  Pages

  46. MQ6

    2  Pages

  47. G 8

    2  Pages

  48. G 5

    2  Pages

  49. Z 5

    1  Page

  50. UCE 24

    1  Page

  51. Worm gear

    7  Pages

  52. MC motors

    8  Pages

  53. Spur gear

    9  Pages

Archived catalogs

  1. DC motors

    43  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.