Three-phase and AC motors
63Pages

{{requestButtons}}

Catalog excerpts

Three-phase and AC motors - 2

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Cable connection, optional plug-in connectorService life:20,000 hours, S1 duty Insulation mat. class: B, optional F System of protection:IP 40, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special gears, special flanges, custom designed Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W1012Nominal speedn > nom rpm27002600Nominal torqueT > nom...

Open the catalog to page 2
Three-phase and AC motors - 3

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 1 (Page Sc-05)(Data upon request)S 567(Page Sc-02)Z 67 (Page St-04) P50(Page P-02) Type Name > Nominal voltage / AC voltage230230 nMnM S 446Worm gear 1-stage rpmnMrpmNm i=2.2512000.111560.1i=55400.15200.2 Diagram upon request i=73860.23710.2 i=102700.22600.3 i=151800.31730.4 i=251080.41040.5 i=30900.4870.6 i=40680.4650.5 i=50540.6520.8 i=60450.5430.8 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if...

Open the catalog to page 3
Three-phase and AC motors - 4

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Cable connection, optional plug-in connectorService life:20,000 hours, S1 duty Insulation mat.class:B, optional F System of protection:IP 40, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W35Nominal speedN > nom rpm12001200Nominal torqueT > nom...

Open the catalog to page 4
Three-phase and AC motors - 5

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 1 (Page Sc-05)(Data upon request)S 567(Page Sc-02)Z 67 (Page St-04) P50(Page P-02) Type Name > Nominal voltage / AC voltage230230 nMnM S 446Worm gear 1-stage rpmNmrpmNm i=2.255330.15330.1i=52400.12400.1 Diagram upon request i=71710.11710.2 i=101200.21200.2 i=15800.2800.3 i=25480.3480.4 i=30400.3400.4 i=40300.2300.4 i=50240.4240.6 i=60200.4200.6 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if...

Open the catalog to page 5
Three-phase and AC motors - 6

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W1926Nominal speedN > nom rpm25002650Nominal torqueT >...

Open the catalog to page 6
Three-phase and AC motors - 7

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 3 (Page Sc-06)(Data upon request)Z 89 (Page St-05)P60(Page P-03) Type Name > Nominal voltage / AC voltage230230 nMnM S 567Worm gear 1-stage rpmNmrpmNm i=3.66940.27360.2i=55000.25300.3 i=102500.42650.5 i=201250.81331.0 i=241040.81101.1 i=30830.9881.2 i=40631.1661.5 i=50501.3531.7 i=60421.7442.3 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary) Additional reductions upon request. nMnM Z 6 Spur...

Open the catalog to page 7
Three-phase and AC motors - 8

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230 Specification Nominal powerP > 2 W711Nominal speedN > nom rpm12501000Nominal torqueT >...

Open the catalog to page 8
Three-phase and AC motors - 9

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:GS 3 (Page Sc-06)(Data upon request)Z 89 (Page St-05)P60(Page P-03) Type Name > Nominal voltage / AC voltage230230 nMnM S 567Worm gear 1-stage rpmNmrpmNm i=3.63470.12780.3i=52500.22000.3 i=101250.31000.6 i=20630.6501.1 i=24520.6421.2 i=30420.7331.4 i=40310.9251.7 i=50251.0201.9 i=60211.3172.5 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor power must be limited if necessary) Additional reductions upon request. nMnM Z 6 Spur gear...

Open the catalog to page 9
Three-phase and AC motors - 10

Properties: Connection: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequenciesRunning capacitor required Connections using K2 type plug-in connectorsService life:20,000 hours, S1 duty Insulation mat. class:B, optional F System of protection:IP 44, optional up to IP 65 Special model:Design for short-time duty with high performance Options:Thermal protection, special shafts, special flanges, custom designed, stainless steel Type Name > Nominal voltagesUAC voltage230230230 Specification Nominal powerP > 2 W31.043.578.5Nominal speedN > nom...

Open the catalog to page 10
Three-phase and AC motors - 11

All torques are calculated with an duty factor of 1!Additional recommended combinations with gear units:M 189(Page St-09)(Data upon request)S 769(Page Sc-04)P80(Page P-04) Type Name > Nominal voltage / AC voltage230230230 nMnMnM GS 3Worm gear 1-stage rpmNmrpmNmrpmNm i=2.59600.310800.311200.55i=54800.55400.65601.05 i=73430.73860.84001.4 i=102400.92701.12801.8 i=151601.21801.51872.6 i=201201.41351.81403.1 i=30801.8902.2933.8 i=50482.2542.7564.7 i=70343.0393.7406.4 i=100243.5274.3287.6 Additional reductions upon request. Additional reductions upon request.* Max. load at the gear output.(Motor...

Open the catalog to page 11

All Gefeg-Neckar Antriebssysteme GmbH catalogs and technical brochures

  1. M 10

    1 Pages

  2. PSA 52

    1 Pages

  3. PM 30

    1 Pages

  4. PSA 68

    1 Pages

  5. G 6

    1 Pages

  6. M 7

    1 Pages

  7. S 769

    1 Pages

  8. MQ 5

    1 Pages

  9. DRIVE SYSTEMS

    12 Pages

  10. M 67

    1 Pages

  11. M189

    1 Pages

  12. Z5

    1 Pages

  13. Z6

    1 Pages

  14. Z8

    1 Pages

  15. Z67

    1 Pages

  16. Z89

    1 Pages

  17. D5

    2 Pages

  18. D6

    2 Pages

  19. D8

    2 Pages

  20. D95

    2 Pages

  21. K8

    2 Pages

  22. K95

    2 Pages

  23. GS1

    1 Pages

  24. GS3

    1 Pages

  25. S345

    1 Pages

  26. S567

    1 Pages

  27. S668

    1 Pages

  28. SC401

    1 Pages

  29. SC401H

    1 Pages

  30. Dg 71

    4 Pages

  31. U 63

    2 Pages

  32. KD 8

    4 Pages

  33. KD 6

    4 Pages

  34. D 8

    4 Pages

  35. D 5

    4 Pages

  36. Es 71

    4 Pages

  37. K 95

    4 Pages

  38. K 5

    4 Pages

  39. PSA 63

    1 Pages

  40. PSA 45

    1 Pages

  41. MSA 8

    1 Pages

  42. MSA 5

    1 Pages

  43. PC 63

    2 Pages

  44. MQ5

    2 Pages

  45. MQ8

    2 Pages

  46. MQ6

    2 Pages

  47. G 8

    2 Pages

  48. G 5

    2 Pages

  49. Z 5

    1 Pages

  50. UCE 24

    1 Pages

  51. Worm gear

    7 Pages

  52. MC motors

    8 Pages

  53. Spur gear

    9 Pages

Archived catalogs

  1. DC motors

    43 Pages