Single-phase asynchronous motor Properties: Service life: Insulation mat.class: System of protection: Special model: Options: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequencies Running capacitor required Cable connection, optional plug-in connector 20,000 hours, S1 duty B, optional F IP 00 (open design) Design for short-time duty with high performance Alloy rotor for higher starting torque Thermal protection, special shafts, custom designed Terminal resistance Input power Running capacitor Weight Moment of inertia Adm. ambient temperature Max. adm. stator temperature Shaft diameter Max. axial force Max. radial force Name Nominal voltages Nominal power Nominal speed Nominal torque Starting torque Nominal current No-load current P2 Nnom Tnom TA Inom I0 Characteristics Locked rotor speed Locked rotor torque Nominal efficiency Connection from motor System technology (tables next page) Worm gear Spur gear Planetary gear Rotary encoder Brake Recommended combinations upon request upon request Last modified: 04/201
Open the catalog to page 1Gear unit combinations • All torques are calculated with an duty factor of 1! Additional recommended combinations upon request Name Nominal voltage / AC voltage from motor Additional reductions upon request. n rpm Spur gear 2-4 stage Additional reductions upon request. n rpm * Max. load at the gear output (Motor power must be limited if necessary) n M n M rpm Nm rpm Nm PM/P 60 Planetary gear 1-3 stage from motor Additional reductions upon request. * Max. load at the gear output (Motor power must be limited if necessary) AC-19
Open the catalog to page 2Single-phase asynchronous motor Properties: Service life: Insulation mat. class: System of protection: Special model: Options: 230 V /50 Hz AC system , optional designs for 110 V / 60 Hz or other voltages / frequencies Running capacitor required Cable connection, optional plug-in connector 20,000 hours, S1 duty B, optional F IP 00 (open design) Design for short-time duty with high performance Alloy rotor for higher starting torque Thermal protection, special shafts, custom designed Terminal resistance Input power Running capacitor Weight Moment of inertia Adm. ambient temperature Max. adm. stator...
Open the catalog to page 3Gear unit combinations • All torques are calculated with an duty factor of 1! Additional recommended combinations upon request Name Nominal voltage / AC voltage from motor Additional reductions upon request. n rpm Additional reductions upon request. M Nm Planetary gear 1-3 stage from motor Additional reductions upon request.
Open the catalog to page 41 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
3 Pages
12 Pages
4 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
6 Pages
2 Pages
4 Pages
7 Pages
8 Pages
9 Pages
2 Pages
7 Pages
43 Pages
63 Pages