1. Catalogs
  2. GEA Tuchenhagen
  3. Feedback Systems

Feedback Systems

Feedback Systems
1 / 36 PagesView full catalog

Feedback Systems

Product catalog summary
Specifications:
The document details specifications for control modules M-1, SES, and SEE, designed for ATEX/Ex zones. The M-1 module can include IP 67 protection, an exhaust air throttle, or be made from VESTAMID® material. SES and SEE modules, also available in VESTAMID®, feature sensor technology for valve position feedback. Additionally, it specifies a 24 V DC, 3-wire PNP AS-Interface-Bus DeviceNet system with a nominal supply voltage of 24 V DC, reverse voltage protection, and short-circuit safety.
Procedures:
Ordering the M-1 module with specific options requires appending codes to the order code. SES and SEE modules have manually adjustable proximity switches for position detection. The T.VIS® P-1 position controller supports automatic initialization and manual programming via push buttons.
Standards and Recommendations:
Loading resistors are recommended for PLC modules with electronic outputs if leakage currents exceed 1.5 mA, suggesting a 15KΩ / 2W resistor. ATEX marking and certification requirements are detailed, with certificates issued for individual components.
Technical Data:
Control modules operate at 12 V DC or 24 V DC with defined power inputs and protection classes. SES offers variants with up to three solenoid valves, while SEE includes a 4/2 way solenoid valve. The system includes a solenoid valve with a 0.85 W power rating and various connection options.
Key Data from Tables:
Tables provide technical specifications, including power supply requirements, current consumption, and protection features. They list available variants and configurations for solenoid valves and feedback options.
Components and Connections:
The system includes solenoid valves and connection options, emphasizing the need for compatible plug sockets. It features a modern position measuring system and microprocessor for intelligent position acquisition.
Visualization and Indicators:
An LED display provides visual feedback, indicating start, end, regulated positions, and errors.
Environmental and Physical Specifications:
The ambient temperature range is 0° to +50°C, with a control air pressure range of 2 to 8 bar. The protection class is IP65, upgradeable to IP67, with a noise level of 72 dB via exhaust air throttle.
Additional Options:
Options include different control module types and connection variants, with specifications for compatible plug sockets.
See more

Catalog excerpts

Feedback Systems-1

Li q u i d s t o V a l u e T.VIS® - GEA Tuchenhagen Ventil-Informations-System / T.VIS® - GEA Tuchenhagen Valve Information System T.VIS® A-8 (automatischer Setup) / T.VIS® A-8 (automatic Setup) T.VIS® A-8 Bestellcode 24 V DC / T.VIS® A-8 Order code 24 V DC T.VIS® M-1 (mechanischer Setup) / T.VIS® M-1 (mechanical Setup) T.VIS® M-1 Bestellcode 24 V DC / 48-130 V AC / T.VIS® M-1 Order code 24 V DC / 48-130 V AC T.VIS® M-1 Bestellcode ASI / DeviceNet / T.VIS® M-1 Order code ASI / DeviceNet Anschlusskopf Typ SES / Control module type SES Anschlusskopf Typ SES (ATEX) Bestellcode / Control module type SES (ATEX) order code Anschlusskopf Typ SEE / Control module type SEE Anschlusskopf Typ SEE (ATEX) Bestellcode / Control module type SEE (ATEX) order code Anschluss Typ 0 / Connection type 0 Anschlusskopf VESTAMID® / Control module VESTAMID® Logikelement NOT / Logic element NOT T.VIS® P-20 Stellungsregler / T.VIS® P-20 Position Controller T.VIS® V-1 Kontrollsysteme / T.VIS® V-1 Monitoring Systems T.VIS® P-1 Kontrollsysteme / T.VIS® P-1 Monitoring Systems Register GEA Mechanical Equipment / GEA Tuchenhagen

 Open the catalog to page 1
Feedback Systems-2

GEA Tuchenhagen T.VIS®, GEA Tuchenhagen Ventil-Informations-System T.VIS®, GEA Tuchenhagen Valve Information System Variable T.VIS® Rückmeldesysteme Die beiden Varianten der T.VIS® Generation bieten die Möglichkeit, je nach den Kundenbedürfnissen variabel zwischen zwei Rückmeldesystemen auswählen zu können. Ob die bewährte Sensortechnik im T.VIS® M-1 oder die hochmoderne Wegmesstechnik im T.VIS® A-8 zum Einsatz kommt, das T.VIS® Rückmeldesystem wird in jedem Fall auf die Kundenanforderungen optimiert! Variable T.VIS® Feedback Systems The two versions of the T.VIS® generation allows the choice...

 Open the catalog to page 2
Feedback Systems-3

GEA Tuchenhagen T.VIS® A-8 (automatischer Setup) Der Aufbau des T.VIS® A-8 Der T.VIS® A-8 ist mit einem präzisen Wegmesssystem zur Positionserfassung ausgerüstet. Das Wegmesssystem ist Bestandteil eines geschlossenen T.VIS® Steuerkopfes welcher zu keiner Zeit mehr geöffnet werden muss. Die notwendige Verkabelung zur Steuerung und Rückmeldung wird stets über von außen zugängliche M12-Steckverbindungen ausgeführt. Die Bedienung und Konfiguration des T.VIS® A-8 erfolgt über zwei auf der Haube angebrachte Drucktaster, die gegen eine ungewollte Fehlbedienung gesichert sind. Die LEFF® Funktion (Low...

 Open the catalog to page 3
Feedback Systems-4

GEA Tuchenhagen T.VIS® A-8 (automatic Setup) Field of application VARIVENT®, ECOVENT®, STERICOM® and VESTA XL valves The structure of the T.VIS® A-8: The T.VIS® A-8 is equipped with a precise path measurement system for position detecting. The path measurement system is part of a closed T.VIS® control module which never has to be opened. The necessary wiring for activation and feedbacks will always be connected from outside via a standard M12 plug. The operation and configuration of the T.VIS® A-8 is enabled by two push buttons on the cap which are secured against unwilled activations during...

 Open the catalog to page 4
Feedback Systems-5

GEA Tuchenhagen T.VIS® A-8 (automatischer Setup) T.VIS® A-8 (automatic Set-Up) Positionserfassung / Position detecting Wegmesssystem / Path measurement Gehäusewerkstoff / Housing material Noryl Umgebungstemperatur / Ambient temperature -20° … + 60° C Steuerluft / Control air Druckbereich / Pressure range: 2 bis 8 bar Norm: gemäß / acc. to ISO 8573-1:2001 Feststoffgehalt / Solid particle content - Qualitätsklasse / Quality class 6* Wassergehalt / Water content - Qualitätsklasse / Quality class 4 Ölgehalt / Oil content - Qualitätsklasse / Quality class 3 Abmessungen Luftanschlüsse Metrisch 6/4...

 Open the catalog to page 5
Feedback Systems-6

GEA Tuchenhagen Art.-Nr. Item Code Beschreibung / Description B 24 V DC, 3-Draht-PNP 24 V DC, 3-wire-PNP Versorgung / Power Supply Betriebsspannung / Nominal supply voltage 24 V DC (+20%, -12,5%) Leerlaufstrom / No-load current ≤ 25 mA Maximale Stromaufnahme / Max. power input 150 mA Verpolungsschutz / Reverse voltage protection Ja / Yes Spezifikation / Specifications Zusatzinformation / Additional information Zertifikat / Certificate CE Eingänge / Inputs Schaltungsart / Switching type 24VDC (PNP) Kurzschlussfest / Short-circuit-proof Ja / Yes Überlastsicher / Overcharge safe Ja / Yes Maximale...

 Open the catalog to page 6
Feedback Systems-7

GEA Tuchenhagen T.VIS® M-1 (mechanischer Setup) Einsatzgebiet - VARIVENT® Ventile - ECOVENT® Ventile - STERICOM® Ventile - VESTA® XL Ventile (mit Pilotventil) - T-smart Der Aufbau des T.VIS® M-1 Der T.VIS® M-1 zeichnet sich durch die bewährte Sensortechnik aus. Die Grundausstattung des Anschlusskopfes umfasst das 24 VDC Anschaltmodul, bis zu zwei Sensoren, die die Rückmeldung der Ventilposition vornehmen und bis zu drei Pilotventile, die installiert werden können! Bei den Anschaltarten AC, DeviceNet und AS-Interface wird dem Standard-Anschaltmodul ein Adaptermodul vorgeschaltet, um diese Anschaltungen...

 Open the catalog to page 7
Feedback Systems-8

GEA Tuchenhagen T.VIS® M-1 (mechanical Set-Up) Field of application - VARIVENT® valves - ECOVENT® valves - STERICOM® valves - VESTA® XL valves (with solenoid valve) - T-smart The structure of the T.VIS® M-1 The T.VIS® M-1 stands out for its proven sensor technology. The basic equipment of the control module comprises the 24 VDC interface module, max. two sensors for carrying out feedback of the valve position and up to three solenoid valves that can be installed! To implement the connection types AC, DeviceNet and AS-Interface, an adapter module is installed upstream of the standard interface...

 Open the catalog to page 8
Feedback Systems-9

GEA Tuchenhagen 24 V DC / 48-130 V AC T.VIS® M-1 (mechanischer Setup) T.VIS® M-1 (mechanical Set-Up) Positionserfassung / Position detecting Sensoren / Sensors Gehäusewerkstoff / Housing material Noryl Umgebungstemperatur / Ambient temperature -20° … + 60° C Steuerluft / Control air Druckbereich / Pressure range: 2 - 8 bar Norm: gemäß / acc. to ISO 8573-1:2001 Feststoffgehalt / Solid particle content - Qualitätsklasse / Quality class 6 Wassergehalt / Water content - Qualitätsklasse / Quality class 4 Ölgehalt / Oil content - Qualitätsklasse / Quality class 3 Abmessungen Luftanschlüsse Metrisch...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.