ECOVENT®

ECOVENT®

ECOVENT®

Product catalog summary
Overview
This document provides technical specifications and features of ECOVENT® Shut-Off and Shuttle Valves, Type N and Type W, designed for simple hygienic process applications. These valves are a cost-effective alternative to the VARIVENT® System, offering reliable function, CIP/SIP capability, and low maintenance.

Specifications
1. Valve Types: Shut-Off Valves (Type N) and Shuttle Valves (Type W) for DN 10/15.
2. Dimensions: All dimensions are provided in millimeters for standard versions.
3. Actuator Design: Standard actuator selection with control air pressure requirements specified.

Features of ECOVENT® Valves
1. Splash-Water Protection: Electrical components are fully protected.
2. Actuator: Sturdy, reversible, with options for spring-to-close/air-to-open configurations.
3. Internal Air Supply: Direct internal air supply from the control module.
4. Open Lantern: Allows visual inspection of the stem seal and valve position.
5. Valve Spindle: Machine rolled finish for long seal life.
6. Cleaning Characteristics: Optimal cleaning without domes and pools.
7. Valve Disks: Manufactured in a single piece for durability.
8. Seal Deformation: Defined deformation ensures long seal life without leakage.

Operational Recommendations
1. Flow Direction: Recommended flow direction is specified to prevent pressure surges during valve closing.
2. Air Pressure: Minimum required air pressure is 4.8 bar.

Housing Combinations
Details on housing combinations are provided, with metric and inch outside diameters specified according to DIN and ASME standards.

Conclusion
ECOVENT® valves are designed to ensure consistent product quality, high productivity, and economical operation and maintenance costs, making them suitable for various process applications.
See more

Catalog excerpts

ECOVENT®-1

Li q u i d s t o V a l u e ECOVENT® Kurzbeschreibung / Short description Absperrventile, Typ N, DN 10/15 / Shut-Off Valves, Type N, DN 10/15 Umschaltventile, Typ W, DN 10/15 / Shuttle Valves, Type W, DN 10/15 Absperrventile, Typ N / Shut-Off Valves, Type N Umschaltventile, Typ W / Shuttle Valves, Type W Register GEA Mechanical Equipment / GEA Tuchenhagen

 Open the catalog to page 1
ECOVENT®-2

GEA Tuchenhagen ECOVENT® Einsitzventile ... …sind die kostengünstige Alternative zum VARIVENT® System für einfache hygienische Prozessanwendungen. Sie sind eine konsequente Weiterentwicklung der bewährten ECOVENT® Baureihe. Sie sind funktionssicher, ClP/SIP-gerecht und wartungsarm. Sie sind ein wesentlicher Faktor für kontinuierliche Produktqualität, hohe Anlagenproduktivität, niedrige Betriebs-, Wartungs- und Instandhaltungskosten. Merkmale der ECOVENT® Ventile 1. Spritzwassergeschützter Anschlusskopf zum Schutz der elektrischen Installation. 6. Das VARIVENT® System hat optimale Reinigungseigenschaften...

 Open the catalog to page 2
ECOVENT®-3

GEA Tuchenhagen ECOVENT® Single Seat Valves ... . . . represent a cost-effective alternative to our VARIVENT® System for process applications and form the next innovative generation of the proven ECOVENT® series. They stand out by reliable function, CIP/SIP-ability and low maintenance, the fundamental factors for achieving consistent product quality, high output rates and economical operating, maintenance and service costs. Features of ECOVENT® valves 1. Electrical components in the control module are fully splash-water protected. 2. Sturdy and reversible actuator — spring-toclose/air-to-open...

 Open the catalog to page 3
ECOVENT®-4

GEA Tuchenhagen ECOVENT® Absperr- und Wechselventile, DN 10/15 ECOVENT® Shut-Off and Shuttle Valves, DN 10/15 ECOVENT®-Absperrventil Typ N ECOVENT® Shut-Off Valve Type N 10 15 X = H + 50 X = H + 50 B C D D1 H H1 Hub Stroke 13x1,5 19x1,5 40 40 65 65 74 74 146 146 303 306 209 212 8,5 8,5 H1 DN DN Ø H Nennweite Valve Size D1 Außendurchmesser nach DIN 11850, Reihe II, DIN 11866, Reihe A Outside diameter acc. to DIN 11850, Row II, DIN 11866, Row A X Metrisch Metric D (erforderlicher Freiraum für Ausbau) (clearance required for maintenance) C Standardantriebsauslegung / Standard actuator selection...

 Open the catalog to page 4
ECOVENT®-5

GEA Tuchenhagen ECOVENT® Absperrventil, Typ N ECOVENT® Shut-Off Valve, Type N Metrisch Metric Außendurchmesser nach DIN 11850, Reihe II, DIN 11866, Reihe A Outside diameter acc. to DIN 11850, Row II, DIN 11866, Row A Nennweite Valve Size X C D H H1 Hub Stroke 50 62 74 96 111 130 29x1,5 41x1,5 53x1,5 70x2 85x2 104x2 B 31 39 41 52 59 70 90 90 90 125 125 125 85 104 104 129 129 169 338 372 378 386 393 402 244 278 284 292 299 308 16 20 26 28 28 28 H DN 25 DN 40 DN 50 DN 65 DN 80 DN 100 A Ø Zoll OD Inch OD D Außendurchmesser in Anlehnung an ASME-BPE-a-2004, DIN 11866, Reihe C Outside diameter following...

 Open the catalog to page 5
ECOVENT®-6

GEA Tuchenhagen ECOVENT® Umschaltventil, Typ W ECOVENT® Change-over Valve, Type W DN 25 DN 40 DN 50 DN 65 DN 80 DN 100 Zoll OD Inch OD Nennweite Valve Size A 29x1,5 41x1,5 53x1,5 70x2 85x2 104x2 B C D H H1 Hub Stroke 50 62 74 96 111 130 Ø 31 39 41 52 59 70 90 90 90 125 125 125 109 109 109 135 135 170 338 372 378 386 393 402 244 278 284 292 299 308 18 26 26 28 28 28 H Nennweite Valve Size Außendurchmesser nach DIN 11850, Reihe II, DIN 11866, Reihe A Outside diameter acc. to DIN 11850, Row II, DIN 11866, Row A X Metrisch Metric Außendurchmesser in Anlehnung an ASME-BPE-a-2004, DIN 11866, Reihe...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.