video corpo

Semi-hermetic Condensing Units
16Pages

{{requestButtons}}

Catalog excerpts

Semi-hermetic Condensing Units - 1

GEA Bock Units - Extended series Semi-hermetic Condensing Units SHG5 L SHG6 L SHGZ7 L engineering for a better world

Open the catalog to page 1
Semi-hermetic Condensing Units - 2

Condenser Units Air-cooled Extension of the existing series of semi-hermetic condensing units The series of condensing units is extended by the SHG5…L and SHG6…L series as well as the two-stage SHGZ7…L version. With the new units GEA Bock offers a comprehensive program with displacement from 5,4 to 122,4 m³/h. Special features Universal Wide range of uses (R134a, R407C, R 404A, R507, R22) for air-conditioning, medium and low temperature refrigeration applications High refrigeration capacity with reduced energy consumption Generously proportioned condensers with optimized tube circulations...

Open the catalog to page 2
Semi-hermetic Condensing Units - 3

Condenser Units Air-cooled Type key - condenser units air-cooled SHGZ X 7 / 2110 - 4S L Air-cooled condensing units Motor variant 3) Number of poles Swept volume Size Ester oil filling 2) Two-stage Series 1) SHG = Hermetic Gas-cooled (suction gas-cooled) = Ester oil filling (HFC refrigerants R134a, R404A, R507, R407C) = More powerful motor e.g. air-conditioning applications References to performance data The stated performance data is based on 20°C suction gas temperature without liquid subcooling at 50 Hz, respectively for SHGZ7 10 K suction gas superheat with liquid subcooling at 50 Hz....

Open the catalog to page 3
Semi-hermetic Condensing Units - 4

Condenser Units Air-cooled single-stage Performance Data Relating to 20 °C suction gas temperature without liquid subcooling Power consumption Pe [kW] Evaporating temperature °C Supplementary cooling or reduced suction gas temperature 96288-10.2013-Gb Subject to change without notice

Open the catalog to page 4
Semi-hermetic Condensing Units - 5

Condenser Units Air-cooled single-stage Power consumption Pe [kW] Evaporating temperature °C Performance Data Relating to 20 °C suction gas temperature without liquid subcooling 96288-10.2013-Gb Subject to change without notice SL-version for air-conditioning range - Performance data for operating points that are not greyed-out, see GEA Bock software Supplementary cooling or reduced suction gas temperature

Open the catalog to page 5
Semi-hermetic Condensing Units - 6

Condenser Units Air-cooled single-stage Performance Data Performance data • Relating to 20 °C suction gas temperature without liquid subcooling SL-version for air-conditioning range - Performance data for operating points that are not greyed-out, see GEA Bock software Supplementary cooling or reduced suction gas temperature 96288-10.2013-Gb Subject to change without notice

Open the catalog to page 6
Semi-hermetic Condensing Units - 7

Condenser Units Air-cooled single-stage Power consumption Pe [kW] Evaporating temperature °C Performance Data Supplementary cooling or reduced suction gas temperature Relating to 20 °C suction gas temperature without liquid subcooling 96288-10.2013-Gb Subject to change without notice SL-version for air-conditioning range - Performance data for operating points that are not greyed-out, see GEA Bock software Supplementary cooling and reduced suction gas temperature

Open the catalog to page 7
Semi-hermetic Condensing Units - 8

Condenser Units Air-cooled single-stage Compressor 1 Displacement Vol50 Hz tage Technical Data Maximum refrigeration charge 3 R134a Part Winding, motors for part winding start Explanations: 1 Further explanations and technical data see brochure “semi-hermetic GEA Bock compressors". 4 380-420 V Y/YY - 3 - 50 Hz PW PW = Part Winding, motors for part winding start (no start unloaders required) 2 Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request. 3 With liquid temperature at 20 °C and 90 % capacity - Winding ratio: SHG(SHA)4 = 66% /...

Open the catalog to page 8
Semi-hermetic Condensing Units - 9

nderungen vorbehalten Änderungen vorbehalten Änderungen vorbehalten ubject to change withoutto change without notice Subject notice Subject to change without notice SV ous réserve de toutesréservemodifications Sous modifications Sous réserve de toutes de toutes modificationsFLA SI Maße in mm in mm Maße in mm Maße imensions in mm in mm Dimensions in mm Dimensions otes Cotes en mm en mm Cotes en mm Saugabsperrventil, Rohr SV (L)* Saugabsperrventil, Rohr Suction line valve, line valve,Suction line valve, tube d’arrêt d’aspiration, Vanne d’arrêt d’aspiration, - Zoll tuyau-- Zoll 42 - 1mm 1/8"...

Open the catalog to page 9
Semi-hermetic Condensing Units - 10

5 6 6 7 Condenser Units Air-cooled single-stage Änderungen vorbehalten SV Saugabsperrventil, Rohr (L)* Suction lineConnections Raccords valve, tube (L)* Vanne d’arrêt d’aspiration, de tuyau (L)* mm HG6/1240 HG6/1410 1/8" HG6/1240 54 - 2 Anschlüsse Anschlüsse Connections Raccords HG6/1080 - Zoll HG6/1080 Subject to change without notice erungen vorbehalten Änderungen vorbehalten (L)* Liquid de tuyau (L)* - Zoll de tuyau (L)*54 - 2 1/8" Zoll mm - Zoll mm 22 - 7/8" 54 - 2 1/8" FLA Flüssigkeitsaustritt, Rohr SV Saugabsperrventil, Rohr SV (L)* Saugabsperrventil,Suction line valve, tube outlet,...

Open the catalog to page 10
Semi-hermetic Condensing Units - 11

Condenser Units Air-cooled single-stage SV = Suction line shut off valve FLA = Liquid outlet SI = Connection safety valve Y1 = Connection liquid side, lockable Y2 = Connection liquid side, not lockable 1 urther compressor connections can be F found in the brochure “semi-hermetic GEA Bock compressors“ Scope of supply and Accessories Scope of supply SHG L Semi-hermetic GEA Bock compressors HG with suction gas-cooling 380-420 V Y/YY - 3 - 50 Hz Condensers with copper pipes and aluminium plates, optimized circulation, improved heat transmissions and extended plate surfaces Fan with...

Open the catalog to page 11
Semi-hermetic Condensing Units - 12

Condenser Units Air-cooled two-stage Technical Data Compressor 1 Displacement Vol50 Hz tage Receiver Capacity Maximum refrigeration charge 3 R404A Part Winding, motors for part winding start Explanations: 1 Further explanations and technical data see brochure “semi-hermetic GEA Bock compressors". 4 380-420 V Y/YY - 3 - 50 Hz PW PW = Part Winding, motors for part winding start (no start unloaders required) 2 Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request. 5 230 V - 1 - 50 Hz 3 With liquid temperature at 20 °C and 90 % capacity...

Open the catalog to page 12

All GEA Bock catalogs and technical brochures

  1. Plusbox