Catalog excerpts
Power Conversion For industrial pump, fan, compressor and other industrial applications.
Open the catalog to page 1Experience Matters For over 100 years, GE has produced countless medium voltage induction machines for the petrochemical, power generation, mining and minerals, water and wastewater industries. These motors are commonly used for centrifugal compressors, blowers, boiler feed pumps, crushers and grinders, multi-stage high pressure pumps such as water injection or pipeline applications. Standards GE motors are designed for, but are not limited to these critical industry standards: NEMA MG1 IEC 60034-1 ANSI C50.41 IEEE 112 API 541 & 547 Applicable ISO, AFBMA, ANSI, ASME, and ASTM requirements...
Open the catalog to page 2Superior Design Meets or exceeds API 541 requirements for Petroleum & Chemical Applications GE provides machines that are fully compliant to API 541 by API. Use of the latest engineering simulation tools and standards, globally recognized among the most stringent. modern modal testing equipment makes it possible for GE You can be assured that you are getting a well-designed and to assure shaft resonances do not impede operation of the reliable product, optimized for your specific application. machine in the specified speed range. GE supplies both flexible and rigid rotor technology. All...
Open the catalog to page 3Built for Durability Stator Construction Rotor Construction Laminations are precision punched from high quality, low loss The magnetic circuit consists of punched thin steel disks electrical sheet steel with a temperature stable insulating film. assembled to form a laminated core mounted on the shaft. The The magnetic core consists of ring laminations compressed laminations are coated with a temperature stable insulating and completely wound before the core package is inserted film to reduce magnetic losses yet maintain dimensional stability in the face of severe thermal and mechanical...
Open the catalog to page 4Wound Rotor Accurate Frequency Response Design Energy Recovery System System resonance can shorten the life of your equipment. GE wound rotor induction motors are designed to operate GE invested in the development and calibration of a new with Slip Energy Recovery drives within a standard range of Reed Critical Frequency (RCF) prediction tool. It arms our 80% to 110% of the rated speed. Every design is optimized engineers with the accurate data they need to create custom to suit each application and to provide maximum energy designs for specific application challenges. savings, effective...
Open the catalog to page 5Weather Protected (WPI) - IP23 (WPII) - IP24W and IP44W Weather Protected (WPI) - IP23 (WPII) - IP24W and IP44W Totally Enclosed Water-to-Air Cooled (TEWAC) - IP54 or IP56 Ratings 60Hz. shown, 50Hz. Available. These ratings are based on 4.1 kV. Enclosures for other voltages may be sized differently. Contact your GE representative for more information. * Enclosures A = WPI / WPII / TEWAC; IP23 / IP44W / IP54 / IP56 B = TEAAC; IP54 / IP56 Totally Enclosed Air-to-Air Cooled (TEAAC) - IP54 or IP56
Open the catalog to page 6Global Expertise Rotating Machine Factories Converter Factories Business Centers Proven Experience Complete Product Offering GE offers a complete portfolio of rotating machines. Innovative Technology Few manufacturers can claim the depth and breadth of experience that GE has in building and delivering electrical and mechanical solutions for customers. World-Class Service GE has the global resources and capabilities to maximize the performance and reliability of your machines. GE is constantly innovating product technologies to meet and exceed customer expectations.
Open the catalog to page 7MAIN OFFICES South Africa, Midrand Tel: +2711237 0000 South Korea, Busan Tel: +82 51 710 9015 Additional Options Monitoring/Protection/Accessories Vibration Temperature Enclosure Electrical Mechanical displacement, velocity or acceleration winding, cooling air, cooling water, bearing and bearing oil anti-condensation heaters, water leakage, differential pressure current transformers, surge capacitors, surge arresters, partial discharge couplers soleplates, coupling guard supports, speed sensing www.gepowerconversion.com © 2014 General Electric Company. All rights reserved. GEA31319 (7/2014)
Open the catalog to page 8All GE Motors catalogs and technical brochures
-
Standard Industrial Motor Catalog
252 Pages
-
Stock Inventory DC Motors
1 Pages
-
MD800 Armored Mill Motor
6 Pages
-
Buyers Guide
174 Pages
-
Oil & Gas
8 Pages
-
XSD Ultra®
4 Pages
-
Quantum® LMV
4 Pages
-
Mining and Minerals
8 Pages
-
XSD Ultra® 661
4 Pages
-
X$D Ultra® 841
4 Pages
-
X$DUltra® 841 IEC
8 Pages
-
Standard Industrial Motor Catalog
230 Pages
Archived catalogs
-
MV7000 Flat Pack (FP)
16 Pages
-
Power Conversion
91 Pages
-
LV 7000-6 and 8
2 Pages
-
case study
1 Pages
-
MV7-Series
5 Pages
-
Standard Industrial Motor Catalog
330 Pages
-
N37
12 Pages
-
D_Harnessing the Power of Wind
20 Pages
-
SVC and STATCOM fact sheet
4 Pages
-
Low Voltage Motors
8 Pages
-
MV6 Medium Voltage Drive
20 Pages
-
LV 7000 Drives
4 Pages
-
Generators Brochure
16 Pages
-
X$D Ultra 841 VSS
6 Pages
-
DC2100e
4 Pages
-
Genuine Parts
6 Pages
-
Synchronous Hydro Generators
10 Pages
-
ProSolar Power Station
3 Pages
-
A new direction for DP
12 Pages
-
Energy $aver
2 Pages
-
X$D Ultra ? 841 VSS
6 Pages
-
MV7000
16 Pages
-
MV4 Series
9 Pages
-
Onduleur Central ProSolar
3 Pages
-
A$DUltra
2 Pages
-
GEA18201A X$D IEC
6 Pages
-
AC and DC Excavator Solution
12 Pages
-
Series 9000-RCM
2 Pages
-
Motors Product Line Brochure
8 Pages
-
2008 Standard Products Catalog
248 Pages
-
GE Motors - Product Line
6 Pages