TOV Modular Voltage Relay Under and overvoltage protection for low and medium voltage industrial installations. Part of a modular system Instantaneous under and overvoltage Time delay under and overvoltage 1/8 standard 19" rack cases available LED indicators and reset button Phase to ground fault detection in isolated neutral systems Trip, auxiliary, power supply alarm Third harmonic filter (single phase) Automatic transfer equipment Automatic control systems Component for complex protection scheme
Open the catalog to page 1
TOV Modular Voltage Relay manufactured using techniques to minimize failures TOV relays are undervoltage and overvoltage relays, single phase or three phase, instantaneous or fixed time. Adjustments are made from dip switches located on the front of the relay. The single phase relays may include a filter for third harmonics, as well as the ability to select between overvoltage and undervoltage operation in the same relay. Connection Diagrams (+) ABC A4 GE Power Management Some of the more common undervoltage applications of the TOV relay are: power consumption Drawout case LED indicating...
Open the catalog to page 2
TOV Modular Voltage Relay Technical Specifications PROTECTION OPERATING TIMES There are Two Operating Modes: 1. Instantaneous (30 to 50 ms) 2. Time delay 130 ms to 25.6 sec in 100 ms steps The same relay can be used in either mode, or in both modes VOLTAGE RANGES Adjustable Voltage Ranges are available as follows: 20 to 275 VAC 50 to 305 VAC 3 to 65 VAC (only in single phase version) in 1 V steps The Maximum Allowable Continuous Voltages are: 400 AC for the 20 to 275 V and 50 to 305 V ranges 200 VAC for the 3 to 66 V range FREQUENCY RANGE With filter POWER SUPPLY AUXILIARY CIRCUIT VOLTAGE...
Open the catalog to page 3All GE Grid Solutions catalogs and technical brochures
-
Static Var Compensator Solutions
12 Pages
-
Kelman TRANSFIX
2 Pages
-
Kelman MINITRANS
2 Pages
-
MIG
3 Pages
-
DTR
4 Pages
-
SPM
8 Pages
-
MDS SD Series
4 Pages
-
MIC
2 Pages
-
Multilin F60
9 Pages
-
Model PT7-1-150 & PT7-1-200
2 Pages
-
Models PT7-2-150 & PT7-2-200
2 Pages
-
Model PT6-2-125
2 Pages
-
Model PT6-1-125
2 Pages
-
Models PTW5-1-110&PTW5-2-110
2 Pages
-
Models PTG4-1-75 & PTG4-2-75
2 Pages
-
Models PTW3-1-60 & PTW3-2-60
2 Pages
-
Models PTG3-1-60 & PTG3-2-60
2 Pages
-
Models PT3-1-45 & PT3-2-45
2 Pages
-
Model 3PT3-60
2 Pages
-
MIG II
8 Pages
-
Model JVW-110C
2 Pages
-
Model JVW-5AC-1
2 Pages
-
Model JVW-5C
2 Pages
-
Multilin T60
9 Pages
-
Multilin 489
9 Pages
-
Multilin™ D25
8 Pages
-
Multilin D485
1 Pages
-
Multilin P485
1 Pages
-
MultiNet
3 Pages
-
iNET-II
4 Pages
-
MDS™ iNET 300
2 Pages
-
MDS iNET 900®
2 Pages
-
Multilin™ PQM II
8 Pages
-
Multilin L90
10 Pages
-
COSI
2 Pages
-
Reason DR60
4 Pages
-
Multilin 850
4 Pages
-
G650
8 Pages
-
Hydran M2
2 Pages
-
MultiLink ML3000 Series
12 Pages
-
TN1U
4 Pages
-
JungleMUX SONET Multiplexer
4 Pages
-
Multilin™ MM200
8 Pages
-
Multilin™ MM300
8 Pages
-
Multilin 339
16 Pages
-
Multilin 469
10 Pages
-
Multilin A60
6 Pages
-
Multilin 350
16 Pages
-
Multilin F650
12 Pages
-
Multilin 750/760
10 Pages
-
F35
8 Pages
-
345
12 Pages
-
745
8 Pages
-
Multilin G30
9 Pages
-
Transmission Overview
9 Pages
-
Air-Core Reactors
8 Pages
-
Multilin HardFiber System
14 Pages
-
Multilin UR & URPlus
18 Pages
-
Multilin C30
6 Pages
-
Voltage Regulators
16 Pages
-
g3 Technology
2 Pages
-
Rectifier
4 Pages
-
RMIO
2 Pages
-
MiCOM Agile P54A/B
2 Pages
-
MultiSync™ 100
6 Pages
-
Multilin G60
9 Pages
-
Multilin D400
12 Pages
-
GL 107X
2 Pages
-
Disconnectors
12 Pages
-
CGVB-05
2 Pages
-
KOTEF
4 Pages
-
Adjustable Height Sub Base
2 Pages
-
HV Transmission Solutions
8 Pages
-
FK
4 Pages
-
B65
4 Pages
-
Safe-NET Network Transformer
8 Pages
-
Green Power Transformers
4 Pages
-
COSI-RogoFlex
2 Pages
-
Grid-GA-L3-COSI_CEVT
2 Pages
-
P50 Agile P154 / P253
4 Pages
-
MiCOM Agile P24x
8 Pages
-
239 Motor Protection
8 Pages
-
Power Transformers
8 Pages
-
smorb
3 Pages
-
MIF II
8 Pages
-
SR family
2 Pages
-
735/737
4 Pages
-
hid
2 Pages
-
dtp
5 Pages
-
IEC Oil Filled & SF
12 Pages
-
Gas Insulated Switchgear
24 Pages
-
Multilin UR & UR Plus
18 Pages
-
M60
8 Pages
-
MDS Orbit Platform Brochure
12 Pages