Overview
The document provides an overview of the Multilin MM200, a digital motor protection and control system for low voltage motor applications. It integrates protection, control, and communication protocols in a compact device suitable for various motor protection applications.
Protection and Control
The MM200 offers advanced protection features such as a motor thermal model, undercurrent and current unbalance protection, acceleration time monitoring, and sensitive ground fault detection. It includes built-in starter logic and supports various motor control configurations like FVNR, FVR, and two-speed operations. The system is equipped with configurable inputs and supports power fail restart.
Metering and Monitoring
The MM200 provides high accuracy metering of current signals and monitors motor loads, thermal capacity, running time, and trip causes. It supports 1A/5A combined CT inputs and includes digital counters for system analysis.
Communications
The device supports networking through RS485 and multiple protocols including Modbus RTU, DeviceNet, and Profibus. It allows simultaneous communications and integrates easily into monitoring and control systems.
EnerVista™ Software
The EnerVista™ Suite simplifies setup, configuration, and monitoring of the MM200. It includes tools for document management, maintenance, and troubleshooting, and supports seamless integration into DCS or SCADA systems.
Applications
The MM200 is suitable for low voltage three-phase motors, MCC and standalone panel mount applications, and process control applications requiring multiple simultaneous communications.
Technical Specifications
The document details the technical specifications of the MM200, including protection features like thermal model settings, current unbalance, undercurrent, mechanical jam, ground fault, and acceleration timer. It also lists certifications and type tests the device conforms to, ensuring compliance with various international standards.
User Interface and Installation
The MM200 features a user-friendly interface with integrated controls and LED indicators. It supports flexible mounting options and includes a handheld display for local interface and diagnostics.
Environmental Specifications
Operating temperature range: -40°C to +90°C. Humidity: Up to 90% non-condensing at 55°C. Pollution degree: II. IP Rating: Base Unit IP20, Control Panel IP54.
Power Supply Specifications
Low Range: Nominal 24 V DC, Range 18 to 36 V DC, Power Consumption 10 W typical. High Range: Nominal 120 to 240 V AC; 125 to 250 V DC, Range 60 to 300 V AC (50 and 60 Hz); 84 to 250 V DC, Power Consumption 10 W typical, Voltage withstand 2 × highest nominal voltage for 10 ms.
Communications
Serial RS485: Baud Rates up to 115kbps, Protocol: Modbus RTU/half duplex, Typical Distance: 1200m, Isolation: 2kV. DeviceNet (Copper): Modes: Slave at 125, 250, 500 kbaud, Connector: 5 pin terminal. Profibus (Copper): Modes: DP V0 Slave, up to 1.5MB, Connector: 5 pin terminal.
Outputs
Configuration: Electromechanical 2 x Form-A and 1 x Form-C, Contact Material: Silver alloy, Operate Time: 10ms. Output Relay Break Capacity (Form A): AC resistive, 120Vac: 5A; 240Vac: 5A; DC resistive, 30Vdc: 5A. Output Relay Break Capacity (Form C): AC resistive, 120Vac: 5A (NO) 5A (NC); 240Vac: 5A (NO) 8A (NC); DC resistive, 30Vdc: 5A.
Inputs
Phase Current Inputs: CT Primary: 0.5A to 1000A, CT Secondary: 1A or 5A, Burden: 0.2VA, Conversion Range: 0.2 to 40 A, Nominal Frequency: 50/60 Hz, Frequency Range: 40-70 Hz. Sensitive Ground Current Input: CT Primary: 0.5A to 15A, Conversion Range: 0.5A to 15A, Accuracy: 0.1A (0.5A to 3.99A), 0.2A (4.0A to 15A). Digital Inputs X7: Fixed Threshold: 24VDC, Recognition Time: 2 cycle recognition, Continuous Current Draw: 4mA, Type: Opto-isolated inputs, Max. Inputs Voltage: 30VDC. Digital Inputs (HI): Nominal voltage 120 V AC to 240 V AC, Recognition time 2 cycles, Continuous current draw 4 mA @120 V AC; 8 mA @ 240 V AC, Voltage range 65 V AC to 300 V AC.
Ordering Information
Control Panel: X - None, B - Basic Control Panel, no USB. Power Supply: L - 24 VDC, H - 60 - 300 VAC. Communication: 1 - RS485 Modbus RTU + DeviceNet Slave, 2 - RS485 Modbus RTU + Profibus DP Slave. Protection: S - Standard Protection & Control.
Trademarks and Copyright
IEC, IEEE, Modbus, NERC, NIST are registered trademarks of their respective organizations. GE, the GE monogram, Multilin, FlexLogic, EnerVista, and CyberSentry are trademarks of General Electric Company. GE reserves the right to make changes to specifications without notice. Copyright 2015, General Electric Company. All Rights Reserved.
See more

Catalog excerpts

Multilin™ MM200-1

Multilin™ MM200 Low Voltage Motor Protection and Control The Multilin MM200 is a digital motor protection and control system, designed for low voltage motor applications that integrates protection, control and multiple communication protocols in a rugged compact device. Easily integrated into new and existing control system architectures, the Multilin MM200 provides comprehensive low voltage motor protection and communications for all types of motor protection applications. • Motor Thermal Model • Undercurrent & Current Unbalance • Acceleration Time • Sensitive Ground Fault • Built-in Starter Logic • Flexible protection, control, and communication options to suit low voltage motor applications • Auto / Manual Control • Small footprint designed specifically for IEC and NEMA MCC applications • Configurable Inputs • Integrated pushbuttons and LED indicators reduce external components and wiring • Power Fail Restart • Flexible DIN rail mounting • Multiple communication protocols allows simple integration into monitoring and control systems. Metering & Monitoring • Optional control panel provides local control • Current, Motor Loads, Thermal Capacity • Universal device for all motor power ratings • No CTs required for less than 5A motor ratings • Motor Running Time, Cause of Trip, Total Number of Trips • Thermistor input to monitor the ambient or motor temperature • Support for Hand Held Display (HHD) that provides a graphical color local interface allowing local operators to view and change setting files and quickly access relay diagnostic information Communications • Networking through RS485 • MCC and standalone Panel Mount Applications • Multiple protocols - Modbus RTU ODVA Compliant DeviceNet Internally powered Profibus • IEC and NEMA Motor Control Center (MCCs) • Simultaneous Communications • Low Voltage Three-Phase Motors • Process control applications • System architecture requiring multiple simultaneous communications EnerVista™ Software • Simplify setup and configuration • Strong document archive and management system • Simplify full featured monitoring and data recording • Stro

 Open the catalog to page 1
Multilin™ MM200-2

Motor Thermal Model To provide optimal protection and maximize run time, the MM200 employs an advanced thermal model, consisting of four key elements: • Overload Curves • Hot/Cold Safe Stall Ratio Mechanical Jam and Acceleration Time TRIP TIME (seconds) The MM200 is a digital motor protection and control system, designed for Low Voltage motor applications. Compact and powerful, the MM200’s protection can be scaled to the specific requirements of your system. reducing the TCU value exponentially, based on the programmed cool time constants. As cooling occurs at different rates for stopped and...

 Open the catalog to page 2
Multilin™ MM200-3

Power Fail Restart EnerVista™ Software The MM200 supports a Power Fail Restart element (PFR), which provides an undervoltage motor restart after a momentary power loss (dip). The undervoltage condition is detected by a digital input associated with an externally mounted voltage relay. The MM200 utilizes the most advanced communications technologies available today making it an easier and more flexible motor protection relay to use and integrate into new and existing infrastructures. Multiple communication ports and protocols allow control and easy access to information from the MM200. All communication...

 Open the catalog to page 3
Multilin™ MM200-4

Viewpoint Monitoring EnerVista™ Integrator Viewpoint Monitoring is a simple-to-use and full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package with the following functionality: EnerVistaTM Integrator is a toolkit that allows seamless integration of Multilin devices into new or existing automation systems. Included in EnerVistaTM Integrator is: • Plug & Play Device Monitoring • OPC/DDE Server • System Single-Line Monitoring & Control • Multilin Drivers • Annunciator Alarm Screens • Automatic Event Retrieval • Trending...

 Open the catalog to page 4
Multilin™ MM200-5

User Interface Front Panel Controls Optional Fieldbus Protocols • Integrated Device Controls Power Supply and Digital Inputs: • Motor Status • Alarm Indication & trip • Communication Status • Additional user LEDs • Auto/Manual RS485 Communications and Thermistor Input • 24 VDC Power Supply • 7 x 24 VDC Inputs (wet) • 60-300VAC Power Supply • 6x AC Inputs • % Motor Load • Sensitive Ground Fault Optional Control Panel Interface • 2 Form A Outputs (5 Amps) • 1 Form C Outputs (5 Amps) Dimensions Side View Front View

 Open the catalog to page 5
Multilin™ MM200-6

HandHeld Display (HHD) The Hand Held Display (HHD) provides a rugged local interface for MM200 Motor Protection Systems where a local display is not used in the MCC. The HHD provides a graphical color local interface to the MM200 Motor Protection Systems allowing local operators to view and change setting files and quickly access relay diagnostic information. The HHD provides a clear and detailed view of all motor settings, diagnostic information and metering data available in the MM200 allowing local operators to make informed decisions on the motors operation. Wiring Diagrams

 Open the catalog to page 6
Multilin™ MM200-7

Wiring Diagrams (Cont)

 Open the catalog to page 7
Multilin™ MM200-8

Technical Specifications INPUTS PHASE CURRENT INPUTS CT Primary: 0.5A to 1000A CT Secondary: 1A or 5A (Both supported as standard) Burden: 0.2VA Conversion Range: 0.2 to 40 A (8x CT) Nominal Frequency: 50/60 Hz Frequency Range: 40-70 Hz Accuracy: (Ext CT) 2% of injected or 1% of 8xCTP Accuracy: (Direct) 2% of injected or 0.1A CT Withstand: 0.2 seconds at 100 x rated current 1.0 second at 50 x rated current 2.0 seconds at 40 x rated current continuous at 3 x rated current (40DegC) SENSITIVE GROUND CURRENT INPUT CT Primary: 0.5A to 15A Conversion Range: 0.5A to 15A, 2000:1 CBCT Accuracy: 0.1A (0.5A...

 Open the catalog to page 8

All GE Grid Solutions catalogs and technical brochures

  1. MIG

    3  Pages

  2. DTR

    4  Pages

  3. SPM

    8  Pages

  4. TOV

    3  Pages

  5. MDS SD Series

    4  Pages

  6. MIC

    2  Pages

  7. Multilin F60

    9  Pages

  8. Model 3PT3-60

    2  Pages

  9. MIG II

    8  Pages

  10. Model JVW-5C

    2  Pages

  11. Multilin T60

    9  Pages

  12. Multilin 489

    9  Pages

  13. MultiNet

    3  Pages

  14. iNET-II

    4  Pages

  15. Multilin L90

    10  Pages

  16. COSI

    2  Pages

  17. Reason DR60

    4  Pages

  18. Multilin 850

    4  Pages

  19. G650

    8  Pages

  20. Hydran M2

    2  Pages

  21. TN1U

    4  Pages

  22. Multilin 339

    16  Pages

  23. Multilin 469

    10  Pages

  24. Multilin A60

    6  Pages

  25. Multilin 350

    16  Pages

  26. Multilin F650

    12  Pages

  27. F35

    8  Pages

  28. 345

    12  Pages

  29. 745

    8  Pages

  30. Multilin G30

    9  Pages

  31. Multilin C30

    6  Pages

  32. g3 Technology

    2  Pages

  33. Rectifier

    4  Pages

  34. RMIO

    2  Pages

  35. Multilin G60

    9  Pages

  36. Multilin D400

    12  Pages

  37. GL 107X

    2  Pages

  38. Disconnectors

    12  Pages

  39. CGVB-05

    2  Pages

  40. KOTEF

    4  Pages

  41. FK

    4  Pages

  42. B65

    4  Pages

  43. COSI-RogoFlex

    2  Pages

  44. smorb

    3  Pages

  45. MIF II

    8  Pages

  46. SR family

    2  Pages

  47. 735/737

    4  Pages

  48. hid

    2  Pages

  49. dtp

    5  Pages

  50. M60

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.