Multilin 489 - 1

Grid Solutions Multilin 489 Economical protection, monitoring and metering for generators The Multilin™ 489 Generator Protection System, a member of the SR family of relays, provides protection, control and advanced communications in a cost effective industry leading draw-out construction. Designed for small and medium sized generators, the 489 delivers advanced protection including generator stator differential protection. The 489 also includes detailed diagnostic information allowing for reduced troubleshooting time. • Loss of excitation & Overexcitation • Generator stator differential & 100% stator ground • Distance backup • Reverse power (anti-motoring) • Ground directional overcurrent • Inadvertent energization • Breaker failure • Complete, secure protection of small to medium sized generators • Stator and bearing thermal and vibration monitoring • Easy to use generator protection system supported by and industry leading suite of software tools. • Negative sequence overcurrent • Advanced protection and monitoring features including the use of RTDs for stator and bearing thermal protection and Analog Inputs for vibration monitoring • Global acceptance as a member of the most renown protection relay product family in the market. • Draw-out construction allowing for minimized downtime and easy removal/installation of the 489 during maintenance routines • Networking interfaces - RS232, RS485, 10Mbps copper Ethernet • Large, user-friendly front panel interface allowing for real-time power monitoring and setpoint access with a display that is easily readable in direct sunlight • Multiple protocols - ModBus™ RTU, ModBus™ TCP/IP, DNP 3.0 Level 2 • Enhanced generator troubleshooting through the use of IRIG-B time synchronized event records, waveform capturing, and data loggers • Simplified setpoint verification testing using built in waveform simulation functionality • Cost effective access to information through industry standard communication hardware (RS232, RS485, 10BaseT Ethernet) and protocols (Modbus RTU, Modbus TCP/IP, DNP 3.0) • Available for use in most extreme harsh locations with the available Harsh Chemical Environment Option Applications • Synchronous or induction generators operating at 25Hz, 50Hz or 60Hz • Primary or backup protection in cogeneration applications Monitoring & Metering • Metering – current, voltage, power, Energy, frequency, power factor • Demand – current, watts, vars, VA • Temperature – 12 RTD inputs • Vibration and Speed – 4 analog transducer inputs • Oscillography – 12 samples/ cycle up to 128 cycles in length • Trending – 8 parameters with up to a 5 second sample rate EnerVista Software • Document and software archiving toolset to keep information up to date • Ease to use real time monitoring, control, and data archiving software available • EnerVista Integrator providing easy in

Open the catalog to page 1
Multilin 489 - 2

489 Generator Protection System Sensitive Directional Power The 489 Generator Protection System provides comprehensive protection, metering, and monitoring of small to medium sized synchronous or induction generators operating at 25, 50 or 60 Hz. The 489 is ideally suited for primary or backup generator protection as well as for use in cogeneration applications. Protection features found in the 489 include: 100% stator ground fault protection is provided through an overvoltage element and an adaptive voltage differential feature responding to the unbalance of the third harmonic at the...

Open the catalog to page 2
Multilin 489 - 3

489 Generator Protection System Loss of Excitation Generator loss of excitation protection is provided through two negative offset mho characteristics as per IEEEC37.102 and has independent pickup delay setting for each characteristic. The loss of excitation element will be blocked from tripping if a VT fuse fail condition is detected or if the Voltage Supervision characteristic is enable and the voltage is measured to be above the user defined level. a negative sequence definite time overcurrent alarm element and a negative sequence timed overcurrent curve tripping element to ensure the...

Open the catalog to page 3
Multilin 489 - 4

489 Generator Protection System Analog Inputs Four analog inputs are available for providing protection and monitoring of generator bearing vibration. The analog inputs are field programmable to measure transducer signals that operator over a range of 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA. Analog Outputs Four analog outputs are available for signaling the value of measured analog quantities to external process control devices such as PLCs. The analog outputs can be ordered to operate over a 4 to 20mA range or a 0 to 1mA range and can be configured to signal a representation of most analog...

Open the catalog to page 4
Multilin 489 - 5

489 Generator Protection System EnerVista Software The EnerVista Suite is an industry-leading set of software programs that simplify every aspect of using the 489 relay. The EnerVista suite provides all the tools to monitor the status of your protected asset, maintain the relay and integrate information measured by the 489 into DCS or SCADA monitoring systems. Convenient COMTRADE and Sequence of Events viewers are an integral part of the 489 Setup software included with every relay to carry out postmortem event analysis. EnerVista Launchpad EnerVista Launchpad is a powerful software package...

Open the catalog to page 5
Multilin 489 - 6

489 Generator Protection System Typical Wiring Multilin 489 Generator Protection System

Open the catalog to page 6
Multilin 489 - 7

489 Generator Protection System Viewpoint Monitoring Viewpoint Maintenance EnerVista Integrator Viewpoint Monitoring is a simple-to-use and full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package with the following functionality: Viewpoint Maintenance provides tools that will create reports on the operating status of the relay, simplify the steps to download fault and event data, and reduce the work required for cyber-security compliance audits. Tools available in Viewpoint Maintenance include: EnerVista Integrator...

Open the catalog to page 7

All GE Grid Solutions catalogs and technical brochures

  1. MIG

    3 Pages

  2. DTR

    4 Pages

  3. SPM

    8 Pages

  4. TOV

    3 Pages

  5. MIC

    2 Pages

  6. Multilin F60

    9 Pages

  7. MIG II

    8 Pages

  8. Model JVW-5C

    2 Pages

  9. Multilin T60

    9 Pages

  10. MultiNet

    3 Pages

  11. iNET-II

    4 Pages

  12. Multilin L90

    10 Pages

  13. COSI

    2 Pages

  14. Reason DR60

    4 Pages

  15. Multilin 850

    4 Pages

  16. G650

    8 Pages

  17. Hydran M2

    2 Pages

  18. TN1U

    4 Pages

  19. Multilin 339

    16 Pages

  20. Multilin 469

    10 Pages

  21. Multilin A60

    6 Pages

  22. Multilin 350

    16 Pages

  23. Multilin F650

    12 Pages

  24. F35

    8 Pages

  25. 345

    12 Pages

  26. 745

    8 Pages

  27. Multilin G30

    9 Pages

  28. Multilin C30

    6 Pages

  29. Rectifier

    4 Pages

  30. RMIO

    2 Pages

  31. Multilin G60

    9 Pages

  32. Multilin D400

    12 Pages

  33. GL 107X

    2 Pages

  34. Disconnectors

    12 Pages

  35. CGVB-05

    2 Pages

  36. KOTEF

    4 Pages

  37. FK

    4 Pages

  38. B65

    4 Pages

  39. smorb

    3 Pages

  40. MIF II

    8 Pages

  41. SR family

    2 Pages

  42. 735/737

    4 Pages

  43. hid

    2 Pages

  44. dtp

    5 Pages

  45. M60

    8 Pages