Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks
12Pages

{{requestButtons}}

Catalog excerpts

Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 1

Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks Product Selection & Application Guide Product Description GE’s Medium Voltage Metal Enclosed Capacitor and Harmonic Filter Banks are designed for industrial, commercial, and utility power systems requiring medium voltage automatic power factor correction. Standard designs are available for placement in outdoor or indoor substations (an enclosure integrity option can be added to allow for placement in publicly accessible areas) for power factor correction, loss reduction, and voltage support. The banks come fully assembled and ready for interconnection. GE’s standard banks can be modified in most circumstances to meet your specific requirements. Contact GE to discuss your requirements and obtain a price quote. GE can provide Power System Studies, Engineering Studies, System Design and Start-up/ Commissioning services.

Open the catalog to page 1
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 2

Application and Selection Guide Medium Voltage Metal Enclosed Equipment

Open the catalog to page 2
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 3

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Capacitor Banks Product Scope • Voltages from 2.4kV through 38 kV • Integral protection and control system • Reactive power ratings to 40,000 kVar in a single enclosure • Compliant with ANSI, IEEE, IEC, CSA, NEC and NESC codes and standards • Short circuit ratings to 61 kA • Banks are “labeled” per the requirements and definitions of articles 100 and 110 of the NEC by an OSHA® approved NRTL confirming compliance with C37.20.3-2001 standard for metal-enclosed switchgear. GE also holds a...

Open the catalog to page 3
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 4

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Capacitor Banks Standard Features Enclosure Lightning Arresters Free standing, compartmentalized, all welded, 11 gauge galvanneal steel construction with 3 point pad-lockable latching handles and stainless steel hinges. The enclosure is painted with a corrosion resistant ANSI gray-61 epoxy paint. NEMA 3R construction is standard; NEMA 12 and 4X are available as an option. Base of enclosure as well as capacitor supports are formed from C4 structural steel. Door stays and windows are...

Open the catalog to page 4
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 5

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Optional Features Digital Power Meter A highly advanced digital power meter, suited to many power and control applications can be supplied as an option. This Intelligent Electronic Device (IED) can take the place of numerous transducers, meters, and control circuits to meet your power monitoring requirements. NEMA 12 or 4X (stainless steel) construction can be provided as an option. Roof Bushings Current Transformer Automatic banks can be shipped with a properly sized medium voltage or low voltage current transformer....

Open the catalog to page 5
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 6

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Capacitor Banks Typical Three-Line Diagram HEAVY DUTY DISTRIBUTION CLASS ARRESTERS V1 VACUUM SWITCHES or CONTACTOR 44 uH TRANSIENT INRUSH REACTORS MAIN INCOMING FUSES CURRENT LIMITING FUSES 1-PER CAPACITOR GROUND SWITCH DOUBLE BUSHING CAPACITORS NEUTRAL UNBALANCE SENSOR MECHANICAL INTERLOCK TO CONTROL CIRCUIT STAGE 2 CUSTOMER POWER CABLES 60HZ 3 PHASE Figure 2 – Number of stages, ratings and specific bank configuration and components are dependent on voltage rating and customer requirements.

Open the catalog to page 6
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 7

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Harmonic Filter Capacitor Banks Product Scope • Voltages from 2.4kV through 38 kV • Integral protection and control system • Reactive power ratings to 40,000 kVar in a single enclosure • Compliant with ANSI, IEEE, IEC, CSA, NEC and NESC codes and standards • Short circuit ratings to 61 kA • Banks are “labeled” per the requirements and definitions of articles 100 and 110 of the NEC by an OSHA approved NRTL confirming compliance with C37.20.3-2001 standard for metal-enclosed switchgear. GE...

Open the catalog to page 7
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 8

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Harmonic Filter Capacitor Banks Standard Features Enclosure Free standing, compartmentalized, all welded, 11 gauge galvanneal steel construction with 3 point pad-lockable latching handles and stainless steel hinges. The enclosure is painted with a corrosion resistant ANSI gray-61 epoxy paint. NEMA 3R construction is standard, NEMA 12 and 4X with 12 gauge stainless steel is available as an option. Base of enclosure as well as capacitor supports are formed from C4 structural steel. Door stays...

Open the catalog to page 8
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 9

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Ancillary Controls A 1/4” X 2” Tin plated ground bus is provided through the width of the enclosure to assist in grounding during maintenance. All phase bus is also Tin plated and rated at a minimum of 135% of the bank nominal current rating. On/Off/Auto Switches are standard with stage on and off indicators. Enclosure lights are provided in the control, main-incoming fuse, and capacitor compartments. A convenience outlet is provided in the control compartment. Automatic Capacitor Bank Controller Capacitor stages are...

Open the catalog to page 9
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 10

Application and Selection Guide Medium Voltage Metal Enclosed Equipment Medium Voltage Metal Enclosed Harmonic Filter Capacitor Banks Typical Three-Line Diagram HEAVY DUTY DISTRIBUTION CLASS ARRESTERS V1 VACUUM SWITCHES or CONTACTOR HARMONIC FILTER REACTORS, TUNED AND RATED AS REQUIRED MAIN INCOMING FUSES CURRENT LIMITING FUSES 1-PER CAPACITOR GROUND SWITCH DOUBLE BUSHING CAPACITORS NEUTRAL UNBALANCE SENSOR MECHANICAL INTERLOCK AIR DISCONNECT SWITCH STAGE 1 TO CONTROL CIRCUIT STAGE 2 CUSTOMER POWER CABLES 60HZ 3 PHASE Figure 5 – Typical Three-Line Diagram of a Metal-Enclosed Harmonic Filter...

Open the catalog to page 10
Medium Voltage Metal Enclosed Capacitor & Harmonic Filter Banks - 11

Application and Selection Guide Medium Voltage Metal Enclosed Equipment GE's metal enclosed capacitor banks are built in accordance with the standard and optional features as previously listed. Alternate designs that meet your specific requirements and site conditions can easily be accommodated. Please contact GE for a quote or to discuss your specific application. Submit supply GE with the following information: Medium Voltage Metal Enclosed Capacitor Banks Total kvar requirements Three-Phase System Short Circuit Level (Symmetrical Amps) Desired KVar per step Desired number of stages...

Open the catalog to page 11

All GE Grid Solutions catalogs and technical brochures

  1. MIG

    3 Pages

  2. DTR

    4 Pages

  3. SPM

    8 Pages

  4. TOV

    3 Pages

  5. MIC

    2 Pages

  6. Multilin F60

    9 Pages

  7. MIG II

    8 Pages

  8. Model JVW-5C

    2 Pages

  9. Multilin T60

    9 Pages

  10. Multilin 489

    9 Pages

  11. MultiNet

    3 Pages

  12. iNET-II

    4 Pages

  13. Multilin L90

    10 Pages

  14. COSI

    2 Pages

  15. Reason DR60

    4 Pages

  16. Multilin 850

    4 Pages

  17. G650

    8 Pages

  18. Hydran M2

    2 Pages

  19. TN1U

    4 Pages

  20. Multilin 339

    16 Pages

  21. Multilin 469

    10 Pages

  22. Multilin A60

    6 Pages

  23. Multilin 350

    16 Pages

  24. Multilin F650

    12 Pages

  25. F35

    8 Pages

  26. 345

    12 Pages

  27. 745

    8 Pages

  28. Multilin G30

    9 Pages

  29. Multilin C30

    6 Pages

  30. Rectifier

    4 Pages

  31. RMIO

    2 Pages

  32. Multilin G60

    9 Pages

  33. Multilin D400

    12 Pages

  34. GL 107X

    2 Pages

  35. Disconnectors

    12 Pages

  36. CGVB-05

    2 Pages

  37. KOTEF

    4 Pages

  38. FK

    4 Pages

  39. B65

    4 Pages

  40. smorb

    3 Pages

  41. MIF II

    8 Pages

  42. SR family

    2 Pages

  43. 735/737

    4 Pages

  44. hid

    2 Pages

  45. dtp

    5 Pages

  46. M60

    8 Pages