Kelman TRANSFIX Extensive on-line DGA & moisture Dissolved Gas Analysis (DGA) and moisture measurement of the insulating oil are recognized as the most important tests for the condition assessment of transformers. Multi-gas DGA has traditionally been confined to the laboratory environment and infrequent off-line manual sampling, forming part of time based maintenance strategies. As the average age of transformers globally continues to rise, the possibility of rapid ageing, unplanned outages and even catastrophic failure between off-line tests also increases, leading many asset owners to adopt on-line DGA monitoring of equipment to increase network reliability. The Kelman™ TRANSFIX offers discrete multigas on-line DGA and moisture monitoring for transformers. Utilizing photo-acoustic spectroscopy (PAS) measurement technology, which is well suited to field application, it provides laboratory challenging levels of precision and repeatability. Full 9 gas oil sampling and analysis can be performed as often as every hour. Through close integration with GE’s powerful Perception™ software suite and/or user's own software, historian and SCADA systems, the TRANSFIX offers full gas-in-oil trending, analysis and diagnostic capabilities including various diagnostic methods prescribed by international standards. Cutting Edge Technology • Nine gases plus moisture in a single monitor • Automated headspace gas extraction and state of the art photo-acoustic spectroscopy (PAS) measurement technology • No carrier or calibration gases required • Long service life with minimal maintenance • Easy installation: no outages required reducing expense and inconvenience for user • No consumables and minimal maintenance reduces running costs and site visits • Extensive remote communications options and protocols available (including IEC® 61850) • Sampling frequency is user-configurable, up to once per hour • Can be connected to normal AC power or protected DC supply • Remote insight into transformer condition enables rapid action to correct any issue detected • Supports new lower flammability ester based oils as well as mineral insulation oils • Discrete measurement of all fault gases facilitates full remote diagnostic without having to go to site and take an oil sample Configurable Alerts • Faults can be detected in their infancy and outage scheduled when less inconvenient and less costly (normal working hours) • Sunlight visible front panel LED arrays • Two alarm levels (one for Caution and one for Alarm) can be set to show increasing severity • Aids condition based and predictive maintenance strategies • Six user configurable alarm relay contacts • Compatible with mineral insulating oils or ester based oils (natural and synthetic • Caution and alarm modes can be used to automatically increase sampling frequency Applications Knowledge of the condition of transformers is essential for all electrical networks and on-line monitoring of transformers is an increasingly vital component of successful asset management programs. The information provided by multi-gas on-line DGA allows valuable asset capabilities to be maximized and expensive failures to be avoided. Capable of monitoring all sizes of transformers, TRANSFIX is most widely employed for monitoring large, system critical or already compromised transformers with a view to extending asset life, preventing unexpected failure and operating on a condition based maintenance schedule. Some examples include: • GSU transformers • HVDC station transformers • Transmission transformers • Mission critical industrial transformer Integrated Solution • Partners Intellix™ MO 150 and BMT 300 products and combines well with some of the GE Industrial Communication products • Can be configured by and data downloaded to GE’s Perception software which provides graphical gas level trending and diagnostic methods based on International standards • Also integrates to Perception Fleet to provide health/risk ranking
Open the catalog to page 1Perception Software TRANSFIX comes as standard with Perception Desktop to help you configure the unit but also download the stored data in order to view gas level trends and analyse the data using diagnostic methods based on International standards. For asset managers with a large number of monitored transformers, Perception Fleet takes it one step further and automatically performs the data analysis to assign a health/risk index to every transformer in your fleet. It then ranks all assets to give an overview of your transformers’ condition/risk and highlight the worst ones requiring urgent attention...
Open the catalog to page 212 Pages
2 Pages
3 Pages
4 Pages
8 Pages
3 Pages
4 Pages
2 Pages
9 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
9 Pages
9 Pages
8 Pages
1 Page
1 Page
3 Pages
4 Pages
2 Pages
2 Pages
8 Pages
10 Pages
2 Pages
4 Pages
4 Pages
8 Pages
2 Pages
12 Pages
4 Pages
4 Pages
8 Pages
8 Pages
16 Pages
10 Pages
6 Pages
16 Pages
12 Pages
10 Pages
8 Pages
12 Pages
8 Pages
9 Pages
9 Pages
8 Pages
14 Pages
18 Pages
6 Pages
16 Pages
2 Pages
4 Pages
2 Pages
2 Pages
6 Pages
9 Pages
12 Pages
2 Pages
12 Pages
2 Pages
4 Pages
2 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
8 Pages
8 Pages
8 Pages
3 Pages
8 Pages
2 Pages
4 Pages
2 Pages
5 Pages
12 Pages
24 Pages
18 Pages
8 Pages
12 Pages