Catalog excerpts

g IEEE/IEC Lightning Arrester Arresters for AC and DC Applications
Open the catalog to page 1
IEEE/IEC Lightning Arresters Overview For more than a century, utilities have relied on GE to deliver electrical products and services to meet their reliability and operational performance needs. GE is a leading provider of transmission and distribution solutions as well as grid automation systems that maximize utilities operational efficiencies and provides their customers with reliable power. Through an alliance with XD Electric, GE has extended its portfolio to include high and ultra-high voltage power equipment, supporting the highest transmission voltage levels in the world. XD...
Open the catalog to page 2
IEEE/IEC Lightning Arresters Advanced Test Facilities Specialized Installation & Commissioning XIHARI is the Xi’an High Voltage Apparatus Research Institute and is an integral part of the XD|GE alliance. XIHARI has extensive testing capabilities at its facility sites, which include: High Power Laboratory, High Voltage Laboratory, Artificial Climate Laboratory, and EMC Laboratory and an Operational Test Circuit for HVDC Thyristor Valves. The testing hall meets the requirements of ISO™/IEC 17025, and boasts some of the largest test equipment in the world, creating capacity to test insulators...
Open the catalog to page 3
IEEE/IEC Lightning Arresters Polymer Arrester Outline Drawings (mm) For specifications on class 3, 4 and 5 ratings, please refer to the tables on pages 7 to 15. 4
Open the catalog to page 4
IEEE/IEC Lightning Arresters Polymer Arrester Outline Drawings (Cont'd) Porcelain Arrester Outline Drawings (mm) For specifications on class 3, 4 and 5 ratings, please refer to the tables on pages 7 to 15.
Open the catalog to page 5
IEEE/IEC Lightning Arresters Porcelain Arrester Outline Drawings (Cont'd) For specifications on class 3, 4 and 5 ratings, please refer to the tables on pages 7 to 15. 6
Open the catalog to page 6
IEEE/IEC Lightning Arresters Class 3 Ratings (Porcelain and Polymer) IEC60099-4 CLASS 3 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 7
IEEE/IEC Lightning Arresters Class 3 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 3 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 8
IEEE/IEC Lightning Arresters Class 4 Ratings (Porcelain and Polymer) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS Um MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP IEC PREVIOUS DUTY TOV 1s kVrms SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV) 1.5 kA
Open the catalog to page 9
IEEE/IEC Lightning Arresters Class 4 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 10
IEEE/IEC Lightning Arresters Class 4 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS Um MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP IEC PREVIOUS DUTY TOV 1s kVrms SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV) 1.5 kA
Open the catalog to page 11
IEEE/IEC Lightning Arresters Class 4 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 12
IEEE/IEC Lightning Arresters Class 5 Ratings (Porcelain and Polymer) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 13
IEEE/IEC Lightning Arresters Class 5 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 14
IEEE/IEC Lightning Arresters Class 5 Ratings (Porcelain and Polymer) (Cont'd) IEC60099-4 CLASS 4 IEEE C62.11 STATION CLASS MINIMUM DESIGNED CREEP ACTUAL DESIGNED CREEP SWITCHING IMPULSE RESIDUAL VOLTAGE .25 KA MAXIMUM 8/20 RESIDUAL VOLTAGE AT INDICATED CURRENT (KV)
Open the catalog to page 15
Digital Energy Toll Free: +1 877-605-6777 Direct: +1 678-844-6777 GE and the GE monogram are trademarks of the General Electric Company. XD Electric is a registered trademark of China XD Electric Group. XIHARI is a registered trademark of the Xi’an High Voltage Apparatus Research Institute Co., Ltd. IEC is a registered trademark of Commission Electrotechnique Internationale. ISO is a registered trademark of the International Organization for Standardization. ANSI is a registered trademark of American National Standards Institute, Incorporated. IEEE is a registered trademark of the Institute...
Open the catalog to page 16All GE Grid Solutions catalogs and technical brochures
-
Static Var Compensator Solutions
12 Pages
-
Kelman TRANSFIX
2 Pages
-
Kelman MINITRANS
2 Pages
-
MIG
3 Pages
-
DTR
4 Pages
-
SPM
8 Pages
-
TOV
3 Pages
-
MDS SD Series
4 Pages
-
MIC
2 Pages
-
Multilin F60
9 Pages
-
Model PT7-1-150 & PT7-1-200
2 Pages
-
Models PT7-2-150 & PT7-2-200
2 Pages
-
Model PT6-2-125
2 Pages
-
Model PT6-1-125
2 Pages
-
Models PTW5-1-110&PTW5-2-110
2 Pages
-
Models PTG4-1-75 & PTG4-2-75
2 Pages
-
Models PTW3-1-60 & PTW3-2-60
2 Pages
-
Models PTG3-1-60 & PTG3-2-60
2 Pages
-
Models PT3-1-45 & PT3-2-45
2 Pages
-
Model 3PT3-60
2 Pages
-
MIG II
8 Pages
-
Model JVW-110C
2 Pages
-
Model JVW-5AC-1
2 Pages
-
Model JVW-5C
2 Pages
-
Multilin T60
9 Pages
-
Multilin 489
9 Pages
-
Multilin™ D25
8 Pages
-
Multilin D485
1 Pages
-
Multilin P485
1 Pages
-
MultiNet
3 Pages
-
iNET-II
4 Pages
-
MDS™ iNET 300
2 Pages
-
MDS iNET 900®
2 Pages
-
Multilin™ PQM II
8 Pages
-
Multilin L90
10 Pages
-
COSI
2 Pages
-
Reason DR60
4 Pages
-
Multilin 850
4 Pages
-
G650
8 Pages
-
Hydran M2
2 Pages
-
MultiLink ML3000 Series
12 Pages
-
TN1U
4 Pages
-
JungleMUX SONET Multiplexer
4 Pages
-
Multilin™ MM200
8 Pages
-
Multilin™ MM300
8 Pages
-
Multilin 339
16 Pages
-
Multilin 469
10 Pages
-
Multilin A60
6 Pages
-
Multilin 350
16 Pages
-
Multilin F650
12 Pages
-
Multilin 750/760
10 Pages
-
F35
8 Pages
-
345
12 Pages
-
745
8 Pages
-
Multilin G30
9 Pages
-
Transmission Overview
9 Pages
-
Air-Core Reactors
8 Pages
-
Multilin HardFiber System
14 Pages
-
Multilin UR & URPlus
18 Pages
-
Multilin C30
6 Pages
-
Voltage Regulators
16 Pages
-
g3 Technology
2 Pages
-
Rectifier
4 Pages
-
RMIO
2 Pages
-
MiCOM Agile P54A/B
2 Pages
-
MultiSync™ 100
6 Pages
-
Multilin G60
9 Pages
-
Multilin D400
12 Pages
-
GL 107X
2 Pages
-
Disconnectors
12 Pages
-
CGVB-05
2 Pages
-
KOTEF
4 Pages
-
Adjustable Height Sub Base
2 Pages
-
HV Transmission Solutions
8 Pages
-
FK
4 Pages
-
B65
4 Pages
-
Safe-NET Network Transformer
8 Pages
-
Green Power Transformers
4 Pages
-
COSI-RogoFlex
2 Pages
-
Grid-GA-L3-COSI_CEVT
2 Pages
-
P50 Agile P154 / P253
4 Pages
-
MiCOM Agile P24x
8 Pages
-
239 Motor Protection
8 Pages
-
Power Transformers
8 Pages
-
smorb
3 Pages
-
MIF II
8 Pages
-
SR family
2 Pages
-
735/737
4 Pages
-
hid
2 Pages
-
dtp
5 Pages
-
IEC Oil Filled & SF
12 Pages
-
Gas Insulated Switchgear
24 Pages
-
Multilin UR & UR Plus
18 Pages
-
M60
8 Pages
-
MDS Orbit Platform Brochure
12 Pages