High impedance DIFFERENTIAL MODULE Auxiliary resistors and varistors for high impedance differential schemes Key Benefits • Includes 2000-ohm resistors to provide security against the effects of CT saturation for through faults • Provides metal oxide varistors (MOV) to clamp secondary peak voltage to less than 2 kV • Use the HID in conjunction with an overcurrent relay for a separate phase, neutral, and negative-sequence overcurrent elements, including instantaneous, definite-time, and inverse time-overcurrent elements for backup overcurrent protection. applications • Single-zone bus protection, reactor protection, or sensitive restricted earth fault protection on grounded, wye-connected power transformer windings • High impedance differential protection for electrical machines such as generators or motors, including lockout logic. Overview High Impedance Differential protection is a well-known principle where stabilization resistors provides immunity against CT saturation during external faults. The HID module provides resistors together with voltage limiters (MOV) to be used with high-speed overcurrent relay in order to get a high impedance differential protection scheme. External CT's are differentially connected exactly as for traditional high impedance differential protection relaying. The overcurrent-relay unit connected in series with the resistors provides highspeed operation for bus faults involving high-magnitude currents. A voltagelimiting element is connected in parallel to avoid excessively high CT secondary voltages which can damage current inputs when bus faults occurred. The procedure for determining the necessary adjustments and the resulting sensitivity to low-current bus faults is very simple and straightforward, requiring only knowledge of the CT secondary excitation characteristics and their secondary impedance. little or no secondary leakage reactance. A latching relay is incorporated, whose contacts are connected to short circuit the resistors once the associated relay has tripped, preventing damage to the associated MOVs. The HID frontplate incorporates a Reset pushbutton to reset the latching relay once the fault has been cleared, in order to elimi- nate the resistors short circuit. The combination of HID module with a high speed overcurrent relay can be applied for bus protection in most cases where CTs having negligible leakage reactance are used. This generally includes any kind of current transformers with a toroidal core if the windings (on the tap used) are completely distributed about the core. Multilin HID High Impedance Differential Module All CTs must have the same rating, and should be a type, like a bushing CT with a distributed secondary winding, that has Digital Energy Multilin

Open the catalog to page 1
hid - 2

HID High Impedance Differential Module Typical Wiring I PHASE A DIFFERENTIAL CURRENT | PHASE B DIFFERENTIAL CURRENT >— | PHASE C DIFFERENTIAL CURRENT >— Protection Relay - WIRING A RELAY OUTPUT ' High Impedance Differential Module Latching relay / Power supply 1 1 winding transformer REF -1 resistor + 1 MOV 2 2 winding transformer REF - 2 resistors + 2 MOV 3 Busbar Applications 3 High impedance differential elements 0 Without latching relay View Guideform specifications Download the instruction manua Review applications notes and support documents View the UR Family brochure

Open the catalog to page 2

All GE Grid Solutions catalogs and technical brochures

  1. MIG

    3 Pages

  2. DTR

    4 Pages

  3. SPM

    8 Pages

  4. TOV

    3 Pages

  5. MIC

    2 Pages

  6. Multilin F60

    9 Pages

  7. MIG II

    8 Pages

  8. Model JVW-5C

    2 Pages

  9. Multilin T60

    9 Pages

  10. Multilin 489

    9 Pages

  11. MultiNet

    3 Pages

  12. iNET-II

    4 Pages

  13. Multilin L90

    10 Pages

  14. COSI

    2 Pages

  15. Reason DR60

    4 Pages

  16. Multilin 850

    4 Pages

  17. G650

    8 Pages

  18. Hydran M2

    2 Pages

  19. TN1U

    4 Pages

  20. Multilin 339

    16 Pages

  21. Multilin 469

    10 Pages

  22. Multilin A60

    6 Pages

  23. Multilin 350

    16 Pages

  24. Multilin F650

    12 Pages

  25. F35

    8 Pages

  26. 345

    12 Pages

  27. 745

    8 Pages

  28. Multilin G30

    9 Pages

  29. Multilin C30

    6 Pages

  30. Rectifier

    4 Pages

  31. RMIO

    2 Pages

  32. Multilin G60

    9 Pages

  33. Multilin D400

    12 Pages

  34. GL 107X

    2 Pages

  35. Disconnectors

    12 Pages

  36. CGVB-05

    2 Pages

  37. KOTEF

    4 Pages

  38. FK

    4 Pages

  39. B65

    4 Pages

  40. smorb

    3 Pages

  41. MIF II

    8 Pages

  42. SR family

    2 Pages

  43. 735/737

    4 Pages

  44. dtp

    5 Pages

  45. M60

    8 Pages