Catalog excerpts
GE Energy Digital Energy Low-Voltage Bypass/Isolation Open Transition Automatic and Manual Transfer Switches • Ideal for mixed (inductive and resistive) mission critical loads • Contact transfer speed less than 100 milliseconds • Bypass/Isolation for ease of ATS maintenance/testing without load loss of power • Ratings 100 to 4000 amperes Ratings & Construction Ratings – Voltage, Ampere and Pole configuration per Order Code Certifications – UL 1008, CSA C22.2 Certifications – Third-party Seismic Certication to IBC 2006, 3.2g @ Ip = 1.5 (operation during event) Enclosure Type – per Order Code Display, Sensing & Time Delays Display – ¼ VGA color graphical with embedded ‘HELP’ menus Electrical Operator – Momentarily energized, high-speed solenoid mechanism Annunciation – High intensity LED for Source Availability (2), Source Connected (2), Transfer Inhibit (not in Auto) Mechanism – Mechanically-held with mechanical interlock to inhibit connection of both sources to the load Source Fail/Restore – Independently adjustable pickup & dropout of 3-phase U/O voltage, U/O Freq, Volts Balance plus Phase Rotation Contacts – GE design and manufactured, silver tungsten alloy with separate arcing contacts on 600A and above ratings for high withstand and close-on capability Time Delays – Gen start, Source 2 stabilize, Source 2 fail override, Retransfer to Source 1, Gen cool down, Independent settings for Fast Test, Time Delay for Generator Voltage Sag Neutral Pole (4 pole only) – Identical construction to phase poles with fully rated main and arcing contacts. Operation via same mechanism as phase poles to prevent sustained connection of source neutrals in separately derived systems, as last-break/first-make transfer. Remote Access – All parameters locally (front USB port) or remotely (serial or Ethernet) Adjustable Controller Construction – Dual-processor based, with dedicated processor for high-speed Serial or Ethernet communications Source Sensing – Direct 120-690V sensing and software configuration of rated voltage and frequency without the need for potential transformers, step-down transformers or DIP switches Control Wiring – All customer connections at one location. All signals in/out relay-isolated via DINmounted relay/terminal blocks. All control wiring via factory-installed wiring harnesses. Control Group Options (see order code) Group A: All standard features, Field re-programmable I/O (4 inputs, 4 outputs), Control Switches (Test with Load, Test no load, Fast Test, Alarm Reset, Auto/Man Re-transfer Source 1, Auto/Man Transfer both sources, Preferred Source select, Commit/No Commit Transfer to Gen, Time Delay Bypass Group B: All features from “A” plus: 10 Userconfigurable Analog & 10 Digital Alarms, 20-channel data logger, 10-channel waveform capture, Auto Load Shed (with voltage, frequency, and kW triggers) Group C: All features from “B” plus: 4 additional field programmable inputs (total 8 inputs, 8 outputs) Additional Standard Features Engine Exerciser – Configurable Periodic Exerciser (7 Event Daily, Weekly, 14 or 28 day) or Clock Exerciser Type (21 Event, 365 day Programmable) System Status Screen – Active state of switch, display of all time delays and alarm conditions Event Recorder – 256 Event, 1ms accuracy, clock sync via Network Time Protocol (NTP) Outage & Test Report Screen – Date/time stamping of: outage or test event, start signal sent, Gen start time, connection to Gen, Max Gen Volts & Freq dip, return of utility, re-transfer to normal External Power Supply – Standard 120VAC input for controller power and communication and 24 VDC input for remote control and annunciation when both sources de-energized Flexible Feature Assignment – Field reassignable I/O for any/all control features In-Phase Monitor – For phase matching prior to Live-Live transfers of load Optional Features (see order code) Serial Communications – High speed, up to 115k Baud Modbus RTU Ethernet Communications – Fast Ethernet, (10/100 Mbit), Modbus TCP/IP Power Quality Metering – True RMS metering, including THD% (up to 8th order) Load Shed – Ability to transfer to de-energized normal source or center position in event of generator overload Integral Surge Protective Device (SPD) – Load-connected medium or high exposure type Group D: All features from “C” plus: 4 additional field programmable inputs (total 12 inputs, 12 outputs) & GE Flexlogic™ userconfigurable control logic Integral Battery Charger – 3 or 10A, 12 or 24VDC type Group M: Manual ATS configuration Lugs – Mechanical or Compression lugs in lieu of standard rear-bus connection on 1600-4000A switches Lugs – Compression lugs in lieu of standard mechanical lugs on 100A-1200A switches
Open the catalog to page 1Order Code – Abbreviated Product Conguration (see full Product Brochure, Publication DEA-405, for full conguration) Operation Amperage Product Type Z2** = Bypass/Isolation O = Open C = 100 Transition D = 150 Vertical Construction Z3** = Bypass/Isolation F = 225 G = 260 Horizontal Construction I = 400 * 1600-3000 Amperage Excluded J = 600 ** Applicable to 1600-3000 Amperage K = 800 L = 1000 M = 1200 N = 1600 O = 2000 P = 2600 Q = 3000 R = 4000 # of Poles 2 = 2 Pole 3 = 3 Pole 4 = 4 Pole Metering & Accessories X = None A = Load Shed D = PQ Metering NEMA Enclosure Voltage Code X = None (Open)...
Open the catalog to page 2All GE Automatic Transfer Switches catalogs and technical brochures
-
Infinity S Power System
28 Pages
-
Galaxy Millennium® SC Controller
12 Pages
-
GPS 4848 Galaxy Power System
28 Pages
-
AC Power Products Overview
8 Pages
-
GTX Series
2 Pages
-
GPS 4827 Infinity Power System
24 Pages
-
CPS6000 Cabinet Power System
20 Pages
-
Product Overview
20 Pages
-
CPS6000 Plant Systems
20 Pages
-
GPS 2436 Infinity Power System
24 Pages
-
Infinity M Power System
20 Pages
-
Infinity B? Power System
20 Pages
-
Slimline Power System
12 Pages
-
Line Power System
12 Pages
-
Micro-BDCBB
8 Pages
-
596 Rectifier Retrofit
8 Pages
-
Secondary DC Distribution
8 Pages
-
827E Inverter System
10 Pages
-
EntelliGuard* TU Trip Unit
4 Pages
-
Product Portfolio
27 Pages
-
GE Total Efficiency? Datacenter
12 Pages
-
Zenith ZTSM& ZTGM
2 Pages