Group: GE Industrial Solutions
Catalog excerpts
GTX Series Automatic Transfer Switch Overview GE’s GTX Series Automatic Transfer Switches are designed for critical industrial, residential, and commercial applications requiring the dependability and ease of operation found in a power contactor switch. • Programmable time delay engine cool down (U) - 3 seconds factory default setting • All time delays can be adjusted using MX70 software • Indicating LEDs for power availability, switch position, and load energized in a logical one line configuration • Pushbuttons for test, engine start (manual), generator exerciser, timer bypass and program cancel MX70 Microprocessor Control Panel • Special status annunciation of in-phase transfer and timer operation • Smart diagnosis program and in phase monitor GTX Transfer Switches are Equipped with an Optional MX70 Microprocessor Control Panel This microprocessor control includes: • Undervoltage sensing (90% pickup/80% dropout) of Utility source • Voltage and frequency sensing of generator source (90% voltage/95% frequency pickup) • Selectable 7, 14, 21 or 28 day (factory set 28 days) generator exerciser timer Enclosure Type The unit is available in: • Power Panel Only • Open Type (non-enclosed, but with a controller) • NEMA 1 (IP20) • NEMA 3R (IP24) • Time Delay Engine Start (P) - 3 seconds • Time Delay Engine Warmup (W) - Transfer to Generator - 3 seconds • Time Delay Utility Stabilization/ Retransfer to Utility (T) - 10 minutes Additional Options Include: A3/A4 Auxiliary contacts (1 each) closed in Source1 and Source 2 positions Advantages • True double throw operation where the single Solenoid Design is inherently inter-locked and prevents contacts from inadvertently stopping between sources or from being in contact with both sources at the same time. • Highly reliable, Low MTBF (mean time between failure) • Special wiring plug design prevents misoperation • Smart diagnostic program and inphase monitor (MX70 option) • Arc quenching grids, enclosed arc chamber and wide contact air gap • Neutral pole break-lastclose-first design,neutral contact is on the same shaft as other poles • Ease of op
Open the catalog to page 1Order Code DIGIT 1,2,3 SERIES DIGIT 4 AMPERE RATING DIGIT 5 #SWITCHED POLES B 2 Pole E 3 Pole F 4 Pole DIGIT 7 MICROPROCESSOR CONTROLLER DIGIT 8 ENCLOSURE TYPE S MX70 X *None (Power Panel Only) S Standard X *None (Power Panel Only) *Digit 8 for Enclosure must = X S Utility - Generator Switching U Utility - Utility Switching X *None (Power Panel Only) X *None (Power Panel Only) A Enclosure IP20 (NEMA 1) B None (Open Style) C Enclosure IP24 (NEMA 3R) For 400V with MX70 microprocessor controller, the operating sensing fail voltage = 85% nominal, and return voltage = 95% nominal. DIGITS 10,11...
Open the catalog to page 2All GE Automatic Transfer Switches catalogs and technical brochures
-
Infinity S Power System
28 Pages
-
Galaxy Millennium® SC Controller
12 Pages
-
GPS 4848 Galaxy Power System
28 Pages
-
AC Power Products Overview
8 Pages
-
GPS 4827 Infinity Power System
24 Pages
-
CPS6000 Cabinet Power System
20 Pages
-
Product Overview
20 Pages
-
CPS6000 Plant Systems
20 Pages
-
GPS 2436 Infinity Power System
24 Pages
-
Infinity M Power System
20 Pages
-
Infinity B? Power System
20 Pages
-
Slimline Power System
12 Pages
-
Line Power System
12 Pages
-
Micro-BDCBB
8 Pages
-
596 Rectifier Retrofit
8 Pages
-
Secondary DC Distribution
8 Pages
-
827E Inverter System
10 Pages
-
EntelliGuard* TU Trip Unit
4 Pages
-
Product Portfolio
27 Pages
-
GE Total Efficiency? Datacenter
12 Pages
-
Zenith ZTSM& ZTGM
2 Pages