Critical Power Automatic Transfer Switch (ATS) Aulomanc Transfer SivilcJi
Open the catalog to page 1GTX Series GE has been providing customers with reliable ATS power switching systems since the 1920’s. GE’s GTX Series Automatic Transfer Switches (ATS) are used to provide a continuous source of power for critical loads by automatically transferring from source1 power to source2 power in the event that source1 voltage encounters undervoltage, phase loss or under frequency. Voltage sensing and system control can be performed via an optional state-of-the-art MX70 microprocessor providing highly accurate control. GE transfer switches are designed for use in emergency or standby systems...
Open the catalog to page 23. Switch position indication 7. Source2 terminals 9. Voltage sensing terminals 1. Main transfer operator 2. Nameplate (includes serial number) 10. Manual operating maintenance handle Electrical Schematic Diagram BR = Bridge Rectifier SN = Normal position limit switch SE = Emergency position limit switch CNE = Main transfer operator SCN/SCE = Operator limit switch Switch on Normal Source • Method of Operation: If source1 fails, a circuit is closed to start the generator. When source2 reaches a predetermined output, the controller will signal to connect the load to source2. • For GTX...
Open the catalog to page 3MX70 Microprocessor Control Panel A. SI (Utility) Available Green LED. - When on, indicates source is acceptable. B. SI (Utility) Position Green LED. - When on, indicates ATS is connected to Utility - When on, indicates source is acceptable. - When on, indicates ATS is connected to Generator. - When blinking, indicates the ATS is timing a Delay - When on steady, indicates the ATS is waiting for both sources to synchronize with each other. - When off and other lights are on, indicates the ATS is working without active time delays or alarms. F. TEST: Press and hold for one second to simulate...
Open the catalog to page 4Power Panel Product Dimensions 40-80Amps Unit: mm/in 2 POLE Unit: mm/in 2 POLE Unit: mm/in 2 POLE Unit: mm/in 2 POLE
Open the catalog to page 5Enclosure Dimensions (mm) F-2000MP -- 40-250Amp, IP20 (NEMA 1) UNIT: mm/in
Open the catalog to page 6Shipping Weights and Packing Dimensions Power Panel Only FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) UNIT: mm/in Open Style UNIT: mm/in Enclosure Style IP20 (Nema 1) FRAME WEIGHT 2 POLE (KGS/LB) WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) UNIT: mm/in Enclosure Style IP24 (Nema 3R) FRAME WEIGHT 3 POLE (KGS/LB) WEIGHT 4 POLE (KGS/LB) WEIGHT 2 POLE (KGS/LB) UNIT: mm/in
Open the catalog to page 7Order Code DIGIT 1,2,3 SERIES DIGIT 4 AMPERE RATING DIGIT 5 #SWITCHED POLES B 2 Pole E 3 Pole F 4 Pole DIGIT 7 MICROPROCESSOR CONTROLLER DIGIT 8 ENCLOSURE TYPE S MX70 X *None (Power Panel Only) S Standard X *None (Power Panel Only) *Digit 8 for Enclosure must = X S Utility - Generator Switching U Utility - Utility Switching X *None (Power Panel Only) X *None (Power Panel Only) A Enclosure IP20 (NEMA 1) B None (Open Style) C Enclosure IP24 (NEMA 3R) For 400V with MX70 microprocessor controller, the operating sensing fail voltage = 85% nominal, and return voltage = 95% nominal. DIGITS 10,11...
Open the catalog to page 8All GE Automatic Transfer Switches catalogs and technical brochures
-
Infinity S Power System
28 Pages
-
Galaxy Millennium® SC Controller
12 Pages
-
GPS 4848 Galaxy Power System
28 Pages
-
AC Power Products Overview
8 Pages
-
GTX Series
2 Pages
-
GPS 4827 Infinity Power System
24 Pages
-
CPS6000 Cabinet Power System
20 Pages
-
Product Overview
20 Pages
-
CPS6000 Plant Systems
20 Pages
-
GPS 2436 Infinity Power System
24 Pages
-
Infinity M Power System
20 Pages
-
Infinity B? Power System
20 Pages
-
Slimline Power System
12 Pages
-
Line Power System
12 Pages
-
Micro-BDCBB
8 Pages
-
596 Rectifier Retrofit
8 Pages
-
Secondary DC Distribution
8 Pages
-
827E Inverter System
10 Pages
-
EntelliGuard* TU Trip Unit
4 Pages
-
Product Portfolio
27 Pages
-
GE Total Efficiency? Datacenter
12 Pages
-
Zenith ZTSM& ZTGM
2 Pages