Water control (General Catalogue)
37Pages

{{requestButtons}}

Catalog excerpts

Water control (General Catalogue) - 2

Water control Level sensors Single and multiple point liquid controls require using sensors appropriate to each specific application. Selection is based in conditions such as water density, temperature, space availability, installation position, ... Using the right sensor ensures smooth system operation. Mechanical design Stress points analysis to create designs promoting maximum operational endurance. Switch Microswitches with high AC capacity, SCR for endurance, Reed for PLC operation. One option adapted to each application. Cable Different cable lengths and materials (PVC, EPR,...

Open the catalog to page 2
Water control (General Catalogue) - 3

Level sensors Clean and potable water Special atmospheres Residential, agriculture and garden pump installations. Industrial environments with specific application constraints. BL SERIES Clean water BW SERIES Potable water BT SERIES High temperature Other sensors Sewage water Street water management and water treatment plants. BR SERIES AC type IM Magnetic level switch Pressure switch BR-L SERIES AC type + LED light

Open the catalog to page 3
Water control (General Catalogue) - 4

Water control Sensors for clean and potable water BL Serie a BW Serie BL and BW Series Level control for filling and emptying tanks or cisterns. Microswitch electrical contacts, changeover 10A (0,5 HP) and 20A (2 HP). The waterproof float switch BL is made up of: • Single outer casing piece in blownmoulded Polyethylene. • Inner chamber built as a single blownmoulded piece for the microswitch and ball basement. • Stainless steel ball. • Non-hygroscopic closed cells injection of expanded polyurethane in the regulator to eliminate the air and to seal hermetically the complete unit. • Maximum...

Open the catalog to page 4
Water control (General Catalogue) - 5

Level sensors Genre low voltage electrical manufacturer BR Serie AC type • ABS cover, oval shape. • Polycloropren cable H05RN-F 1mm2 cross-section. • Counterbalance sensor. • Resin encapsulated. • Shock resistant. • Maximum working pressure 4 bar at 20°C. • Density from 0,95 to 1,10 gr/cm3 • Supply A.C. • Multivoltage 24/48/110/220/380 V. • Rating: 2 A. • Solid state switch SCR.

Open the catalog to page 5
Water control (General Catalogue) - 6

Water control Sewage water BR-L Serie AC type with light The new level float BR-L integrates a multiLED high performance lamp providing a practical solution in maintenance operations on wells, coffers and other spaces where visibility is limited. • To be used in automation and electronic control pumps • Magnetic switch - voltage 2800 -12V DC / 1100Q -24V DC • Maximum working pressure 4 bar at 20 °C • Working temperature 0 to 70 °C • Multiled lamp 4W/230V • Beam intensity 260 lumens • Lifetime 50.000h • Beam range 220° • Protection degree IPX7 • Density from 0,95 to 1,10 gr/cm3 (other...

Open the catalog to page 6
Water control (General Catalogue) - 7

low voltage electrical manufacturer Level sensors Special atmospheres Dimensions BG Serie Gasoil Regulation of particularly diesel oil, water and hydrocarbon mixture, motor oils, tools machine oils, etc. The level regulator is EX homologated according to ATEX normative for uses in potentially explosive environment due to the presence of gas, vapours or fogs. The submerged float switch BGX consists of: • A single outer piece in blownmoulded Polythene. • Internal weight fixing the rotation centre (gravity centre) close to the cable connection. • Electric changeover contact max 21,4 mA - 9,6...

Open the catalog to page 7
Water control (General Catalogue) - 8

Water control Other sensors SCI Flooding sensor The SCI sensor is used in conjunction with level controls to prevent the risk of flooding in warehouses, car parks, shops, offices, garages, ... The associated level control typically activate a pumping system to drain water or an alarm system to prevent the person in charge. These sensors are characterised by their very small size, built-in central hole for easy installation and its combinable layout setting. • IP68 Protection • False signal proof Reference Installation example Reset function When the relay switches it does not return to the...

Open the catalog to page 8
Water control (General Catalogue) - 9

low voltage electrical manufacturer Level sensors Dimensions IM Magnetic sensor Mini level magnetic switch especially designed to detect the maximum level in small tanks or to operate in particularly narrow wells where the installation of a conventional float level may have operational problems. • ABS cover in tubular shape • Lift type float - optical sensor • Switch encapsulated in resin - shock resistant • Polycloropren cable with high pollution resistance • Maximum working pressure 4 bar at 20°C • Density from 0,95 to 1,10 gr/cm3 Dimensions Reference Cable Input Mechanical pressure...

Open the catalog to page 9
Water control (General Catalogue) - 10

Water control Pump control relays «Modular electronics for level monitoring and pump load optimisation on your industrial control systems.» Managing water and conductive liquids are an essential part of modern societies illustrated in water plants, factory production processes, agriculture irrigation, pools,.. Pumps are the core of liquid flow systems and they require efficient control in order to avoid service continuity problems and expensive costs associated to system breakdowns such as pump dry running. Industrial automation systems are often characterised by operating with unusual...

Open the catalog to page 10
Water control (General Catalogue) - 11

low voltage electrical manufacturer Pump control relays Product overview Level control relays Alternating2 modules snap Din relays Single level HN12 Single level with 3 intermediate levels HN12A Simultaneous Alternating relay (3 outputs) AR03 Level control relays 4 modules plug-in Single level HN1P HN1PLD EMC protection Electromagnetic interferences are characteristic of industrial environments and have a particular impact on control relays. Products have been designed and tested to resist electrostatic and transient disturbances under category 3 of pollution degree conditions....

Open the catalog to page 11
Water control (General Catalogue) - 12

Water control Pump control relays General characteristics Specific transformer with enhanced performance against voltage variations and temperature Air gaps for increased insulation On product information including relay characteristics and wiring diagram on the side Chip architecture designed for industrial harsh environments Modular design fits into distribution and industrial panels Sensitivity adjustment direct on the product front face Frontal LEDs for status indication simplify monitoring Built-in varistor protection against surges Control devices are normally installed in areas with...

Open the catalog to page 12

All GAVE ELECTRO catalogs and technical brochures